{"title":"Ash Fusion Systems","description":"\u003cp\u003eAsh Fusion Systems\u003c\/p\u003e","products":[{"product_id":"model-paf-2014-single-furnace-ash-fusion-system-230-vac-1-ph-50-60-hz","title":"Model PAF 2014 Single Furnace Ash Fusion System, 230 Vac \/ 1 Ph \/ 50-60 Hz","description":"The Preiser Scientific Ash Fusion System is designed to determine ash cone deformation temperatures in coal and coke ash per ASTM Standard D-1857 and ISO Standard 540 (CO\/CO2 reducing atmosphere option).The Model PAF 2014 is comprised of a furnace, control tower, and a user interface PC.  An all-in-one style PC running Windows® operating system accommodates both image collection and analysis concurrently.  The mechanical structure features a functional design offering a user friendly operation coupled with very low maintenance.  The swing away camera mounting allows for easy image alignment and unobstructed sample insertion on both the single and dual furnace models.  The control tower consists of the furnace temperature controller, over temperature protection, and video capture.  Video and furnace communications to the user PC are via a single USB interface transferring furnace command and query requests along with live streaming video from furnace cameras.The analysis software allows the user to manually review and generate reports of completed tests.  An autosuggest algorithm is available to pre-populate analysis for the laboratory technicians’ review and refinement.  Test results, log files, and instrument settings can be viewed within the program.  These files can be directed to a printer, forwarded with built in email, viewed on a shared drive, or accessed via a LIMS system.  Instrument data storage allows the accumulation of approximately of 5 years of test data and images.  It is suggested that data archiving be scheduled on a 6-12 month basis for heavy instrument usage, and longer intervals for lighter use.  An in-program Help Manual provides operational information and reference.  Remote on-line assistance and training can be provided.\u003cstrong\u003eFeatures\u003c\/strong\u003e•    Single Furnace Configuration•    6 to 8 Samples per Run•    Manual or Auto Suggest Analysis•    Temperature Ramp Rate can be adjusted from 1ºF to 20ºF\/minute (1ºC to 12ºC\/minute)•    Sample temperature zone can be  calibrated with  two-point melting standards (gold and nickel)•    External Single-Arm Camera Positioning•    Direct View Camera System w\/IR Filtering•    Only 4 Heating Elements Required•    Very Low (0.8-1.0LPM) Gas Consumption•    Requires No Purge Gas\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003ctable style=\"border-color:\" solid align=\"left\" border=\"0\" border-width:=\"\" border-style:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e416ºC to 1555ºC (750ºF to 2800ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Ramp Rate\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eUser programmable from 1ºC to 12ºC\/minute (1ºF to 20ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Display\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eºC or ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eMaximum Sample Load\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e6-8 samples per analysis (single furnace)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eConforms to Methods\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eASTM \u0026amp; ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eAsh Fusibility Determination\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eManual or Auto Suggested (IT, ST, HT, FT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eAnalysis Time\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e3-4 hours typical cycle time (depending on ramp rate and temperature range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eGas Requirements                    Oxidizing:     Reducing:\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eO2 and CO2 mixtures 0.9 lpm at 20psi  (1.7bar) ±10%CO and CO2 mixtures 0.9 lpm at 20psi  (1.7bar) ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eExhaust \u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e230 cfm flow,  6 inch axial exhaust fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eSupplied with CO monitor Three level furnace over temperature protection (temperature controller,      overtemp controller, user PC monitoring.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e  230Vac \/ 1ph \/ 50-60Hz \/ 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Preiser Scientific Inc","offers":[{"title":"EA (1)","offer_id":51111698366779,"sku":"Z90-8252-01-EA","price":63695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/Z90-8252-01.png?v=1784722586"},{"product_id":"model-paf-2014-dual-furnace-ash-fusion-system-230-vac-1-ph-50-60-hz","title":"Model PAF 2014 Dual Furnace Ash Fusion System, 230 Vac \/ 1 Ph \/ 50-60 Hz","description":"The Preiser Scientific Ash Fusion System is designed to determine ash cone deformation temperatures in coal and coke ash per ASTM Standard D-1857 and ISO Standard 540 (CO\/CO2 reducing atmosphere option).The Model PAF 2014 Dual is comprised of two furnaces, control tower, and a user interface PC.  An all-in-one style PC running Windows® operating system accommodates both image collection and analysis concurrently.The mechanical structure features a functional design offering a user friendly operation coupled with very low maintenance.  The swing away camera mounting allows for easy image alignment and unobstructed sample insertion on both the single and dual furnace models.  The control tower consists of the furnace temperature controller, over temperature protection, and video capture.  Video and furnace communications to the user PC are via a single USB interface transferring furnace command and query requests along with live streaming video from furnace cameras.The analysis software allows the user to manually review and generate reports of completed tests.  An autosuggest algorithm is available to pre-populate analysis for the laboratory technicians’ review and refinement.  Test results, log files, and instrument settings can be viewed within the program.  These files can be directed to a printer, forwarded with built in email, viewed on a shared drive, or accessed via a LIMS system.  Instrument data storage allows the accumulation of approximately of 5 years of test data and images.  It is suggested that data archiving be scheduled on a 6-12 month basis for heavy instrument usage, and longer intervals for lighter use.  An in-program Help Manual provides operational information and reference.  Remote on-line assistance and training can be provided.\u003cstrong\u003eFeatures\u003c\/strong\u003e•    Dual Furnace Configuration•    12 to 16 Samples per Run•    Manual or Auto Suggest Analysis•    Temperature Ramp Rate can be adjusted from 1ºF to 20ºF\/minute (1ºC to 12ºC\/minute)•    Sample temperature zone can be  calibrated with  two-point melting standards (gold and nickel)•    External Single-Arm Camera Positioning•    Direct View Camera System w\/IR Filtering•    Only 4 Heating Elements Required•    Very Low (0.8-1.0LPM) Gas Consumption•    Requires No Purge Gas\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003ctable style=\"border-color:\" solid border=\"0\" align=\"left\" border-width:=\"\" border-style:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e416ºC to 1555ºC (750ºF to 2800ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Ramp Rate\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eUser programmable from 1ºC to 12ºC\/minute (1ºF to 20ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eTemperature Display\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eºC or ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eMaximum Sample Load\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e12-16 samples per analysis (dual furnace)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eConforms to Methods\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eASTM \u0026amp; ISO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eAsh Fusibility Determination\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eManual or Auto Suggested (IT, ST, HT, FT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eAnalysis Time\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e3-4 hours typical cycle time (depending on ramp rate and temperature range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eGas Requirements                    Oxidizing:     Reducing:\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eO2 and CO2 mixtures 0.9 lpm at 20psi  (1.7bar) ±10%CO and CO2 mixtures 0.9 lpm at 20psi  (1.7bar) ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eExhaust \u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e230 cfm flow,  6 inch axial exhaust fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003eSupplied with CO monitor Three level furnace over temperature protection (temperature controller,      overtemp controller, user PC monitoring.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" border-color: border-style: solid border-width:\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd style=\"border-color:\" border-style: solid border-width:\u003e  230Vac \/ 1ph \/ 50-60Hz \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Preiser Scientific Inc","offers":[{"title":"EA (1)","offer_id":51111698399547,"sku":"Z90-8252-02-EA","price":90934.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/Z90-8252-02.png?v=1784722591"},{"product_id":"digital-ash-fusion-system-for-biomass-220-240-v-1-phase-50-60-hz-verder-scientific-cafg5-bio-230sn","title":"Carbolite-Gero Digital Ash Fusion System for Biomass, 220-240 V, 1 Phase, 50\/60 Hz, Verder Scientific, CAFG5-BIO-230SN","description":"\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eCarbolite®-Gero's Digital Ash Fusion System for Biomass, 220-240V, 1 Phase, 50\/60Hz, CAFG5-BIO-230SN — \u003cspan style=\"color: #000080;\"\u003eOther Models Available upon Request\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eThe CAF G5 is designed to test ash fusibility, and optionally, the increasingly popular determination of biomass or solid recovered fuels testing and conforms to the Standards ISO 540:2008; ASTM D1857\/D1857M-04 (2010); DD CEN\/TS 15370-1:2006 (biomass); DD CEN\/TR 15404:2010 (solids recovered fuels (SRF)).  Its automatic and continuous recording digital images frees the technician for other tasks while tests are in progress with the ability to review the results later.  This new system greatly enhances both the quality of the images and test results which increases the efficiency of the laboratory.  With maximum temperature of 1600 °C (2910 °F), this instrument is suitable for both biomass and coal testing.  Also, it can be equipped with an optional work tube integrated lighting system for testing low \"initial deformation\" temperature of SRF or biomass samples.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew analysis software which can be used in fully automatic or manual modes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew software zoom function to enable accurate post-test analysis of individual samples with improved resolution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew one configurable grid assigned to each test piece\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew temperature controller program set up within the software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew space saving embedded computer with Windows 7 Embedded Professional software runs future proof firmware\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew default software settings and individual analysis form for coal ash, biomass, and SRF\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew optional \u003cspan style=\"font-size: small;\"\u003ework tube integrated lighting system for testing low \"initial deformation\" temperature of SRF or biomass samples\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eLightweight insulation allows quick cooling permitting multiple test runs to be completed during the day\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eAutomated digital image capture of samples—image recording frequency adjustable from every 1 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e to ever 20 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e increments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e1600 °C (2910 °F)\u003c\/span\u003e tube furnace with integral SiC elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eExternal link to embedded PC \u0026amp; Software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFlow meters for oxidizing, reducing gas flow (dependent on requirements of method)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003e79 mm inner diameter work tube allows more than 6 samples\/run\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eGas tight seal for efficient use of gases and safety\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic temperature programmer with multiple PID control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eGas inlets for reducing, oxidizing, and purging gases\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eOxidizing or reducing gas selection switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFurnace\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eDigital Camera System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003ePC and software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eCAF controller with multiple PID control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border: 1px solid #000000; width: 533px; height: 921px;\" border=\"1\" frame=\"box\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUp to 1600 °C (1600 °C required for some biomass samples) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Precision\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 3 °C above 800 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Ramp Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e8 °C per minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital multiple PID terms with gain scheduling\u003cbr\u003e and multi offset parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWork Tube Dimensions \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e79 mm internal diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTube Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMullite\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eHeating Elements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSilcon carbide x 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Sample Load\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eConforms to Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e BS ISO 540:2008; ASTM D1857\/D1857M-04 (2010); DD CEN\/TS 15370-1:2006 (biomass); DD CEN\/TR 15404:2010 (solids recovered fuels (SRF))\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAsh Fusibility Determination\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic or Manual (Coal \u0026amp; coke: DT, ST, H, FT)\u003cbr\u003e (Biomass\/SRF: IST, DT, HT, FT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAnalysis Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e3 runs per working day (including cool down times)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eImage Collection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital — up to 1 frame per 1 °C rise in temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eImage Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1280 x 1024 pixels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eGas Requirements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e(Specific gas choice must be made at time of ordering.\u003cbr\u003e\u003cstrong\u003eCall for recommendation\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Purge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eN2 or CO2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Oxidizing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eO2 or Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Reducing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCO + CO2 or H2 + CO2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eVentilation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eForced air ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eExhaust\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003ePipe to be vented into a separate fume hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSafety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eFail safe gas system and CO alarm supplied\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePhysical Dimensions (mm)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e700 (h) x 505 (w) x 765 (case depth) x 970 (overall case depth)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWeight (kg) (furnace)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e84\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e220-240V, 50-60\/Hz, Single phase, 50 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower Switching\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSolid state relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Power Consumption (kW)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eEnvironmental Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Operating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e5 °C — 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Relative Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum 80% up to 31 °C decreasing linearly to 50% at 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eOvertemperature Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital with single high alarm relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111698596155,"sku":"Z90-8253-04-EA","price":77740.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/Z90-8253-04.png?v=1784722598"},{"product_id":"digital-ash-fusion-system-for-coal-coke-220-240-v-1-phase-50-60-hz-verder-scientific-cafg5-co-230sn","title":"Carbolite-Gero Digital Ash Fusion System for Coal \u0026 Coke, 220-240 V, 1 Phase, 50\/60 Hz, Verder Scientific, CAFG5-CO-230SN","description":"\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eCarbolite®-Gero's Digital Ash Fusion System for Coal \u0026amp; Coke (CO + CO2 Reducing Gas\/Air Oxidizing Gas\/Nitrogen Purge Gas), 220-240V, 1 Phase, 50\/60Hz, CAFG5-CO-230SN — \u003cspan style=\"color: #000080;\"\u003eOther Models Available upon Request\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003eThe CAF G5 is designed to test ash fusibility, and optionally, the increasingly popular determination of biomass or solid recovered fuels testing and conforms to the Standards ISO 540:2008; ASTM D1857\/D1857M-04 (2010); DD CEN\/TS 15370-1:2006 (biomass); DD CEN\/TR 15404:2010 (solids recovered fuels (SRF)).  Its automatic and continuous recording digital images frees the technician for other tasks while tests are in progress with the ability to review the results later.  This new system greatly enhances both the quality of the images and test results which increases the efficiency of the laboratory.  With maximum temperature of 1600 °C (2910 °F), this instrument is suitable for both biomass and coal testing.  Also, it can be equipped with an optional work tube integrated lighting system for testing low \"initial deformation\" temperature of SRF or biomass samples.\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eFeatures:\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew analysis software which can be used in fully automatic or manual modes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew software zoom function to enable accurate post-test analysis of individual samples with improved resolution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew one configurable grid assigned to each test piece\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew temperature controller program set up within the software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew space saving embedded computer with Windows 7 Embedded Professional software runs future proof firmware\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew default software settings and individual analysis form for coal ash, biomass, and SRF\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eNew optional \u003cspan style=\"font-size: small;\"\u003ework tube integrated lighting system for testing low \"initial deformation\" temperature of SRF or biomass samples\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eLightweight insulation allows quick cooling permitting multiple test runs to be completed during the day\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eAutomated digital image capture of samples—image recording frequency adjustable from every 1 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e to ever 20 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e increments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e1600 °C (2910 °F)\u003c\/span\u003e tube furnace with integral SiC elements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eExternal link to embedded PC \u0026amp; Software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFlow meters for oxidizing, reducing gas flow (dependent on requirements of method)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003e79 mm inner diameter work tube allows more than 6 samples\/run\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eGas tight seal for efficient use of gases and safety\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic temperature programmer with multiple PID control\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eGas inlets for reducing, oxidizing, and purging gases\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eOxidizing or reducing gas selection switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFurnace\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eDigital Camera System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003ePC and software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eCAF controller with multiple PID control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border-color: #000000; border-width: 1px; width: 533px; height: 921px;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUp to 1600 °C (1600 °C required for some biomass samples) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Precision\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 3 °C above 800 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Ramp Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e8 °C per minute\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital multiple PID terms with gain scheduling\u003cbr\u003e and multi offset parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWork Tube Dimensions \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e79 mm internal diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTube Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMullite\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eHeating Elements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSilcon carbide x 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Sample Load\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eConforms to Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e BS ISO 540:2008; ASTM D1857\/D1857M-04 (2010); DD CEN\/TS 15370-1:2006 (biomass); DD CEN\/TR 15404:2010 (solids recovered fuels (SRF))\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAsh Fusibility Determination\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic or Manual (Coal \u0026amp; coke: DT, ST, H, FT)\u003cbr\u003e (Biomass\/SRF: IST, DT, HT, FT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAnalysis Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e3 runs per working day (including cool down times)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eImage Collection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital — up to 1 frame per 1 °C rise in temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eImage Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1280 x 1024 pixels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eGas Requirements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e(Specific gas choice must be made at time of ordering.\u003cbr\u003e\u003cstrong\u003eCall for recommendation\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Purge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eN2 or CO2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Oxidizing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eO2 or Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Reducing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCO + CO2 or H2 + CO2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eVentilation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eForced air ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eExhaust\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003ePipe to be vented into a separate fume hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSafety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eFail safe gas system and CO alarm supplied\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePhysical Dimensions (mm)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e700 (h) x 505 (w) x 765 (case depth) x 970 (overall case depth)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWeight (kg) (furnace)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e84\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e220-240V, 50-60\/Hz, Single phase, 50 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower Switching\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSolid state relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum Power Consumption (kW)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eEnvironmental Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Operating Conditions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e5 °C — 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e     Relative Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMaximum 80% up to 31 °C decreasing linearly to 50% at 40 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eOvertemperature Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDigital with single high alarm relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111698628923,"sku":"Z90-8253-06-EA","price":56010.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/Z90-8253-06.png?v=1784722600"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/3010201.jpg?v=1761680440","url":"https:\/\/preiser.com\/collections\/ash-fusion-systems.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}