{"title":"Hoods","description":"\u003cp\u003eHoods\u003c\/p\u003e","products":[{"product_id":"primeaire-add-air-fume-hood","title":"PrimeAire Add Air Fume Hood","description":"\u003cp data-canvas-width=\"\"\u003e\u003c\/p\u003e\u003cdiv data-canvas-width=\"\"\u003e\n\u003cspan style=\"\" font-family: arial font-size: small\u003eThe BMC Airfoil Add Air Fume Hood provides added \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eeconomy through the use of a front mount “add air \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eplenum” that can supply up to 70 percent of the total Hood \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eair volume requirement from an outside source.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv data-canvas-width=\"\"\u003e\n\u003cspan style=\"\" font-family: arial font-size: small\u003eThe superstructure entrance of the Add Air Fume Hood is \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eframed with inward angled members that minimize \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eturbulence and provide smooth movement of air into the \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eHood. This design allows for efficient operation of the Fume \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eHood at face velocities ranging from 60 to 150 FPM.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eAdditionally, the built-in bypass feature above the Hood \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003esash works to maintain a relatively constant face velocity \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eat any sash position.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eThe front mounted add air plenum of the Airfoil Add Air \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eFume Hood utilizes a series of diffusers and louvers to \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eprovide a uniform flow of supply air to the face of the Fume \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eHood. This uniform air flow allows for providing up to 70% \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eof the overall air volume requirements of the Hood through \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ethe add air plenum.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eAs with other BMC Fume Hoods, the Add Air Hood comes \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eequipped with a full view laminated safety glass sash with \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ea full width flush pull and counterweight for easy \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eoperation. A lower airfoil acts as sash stop that provides a \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e1\"\" space for air to continuously flow into the Hood and \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eacross the work surface.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eDouble wall construction of the superstructure provides \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eadequate space on both sides of the Hood for installation of \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eservice fixtures and routing of plumbing and electrical lines.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eThe lining of the interior work area of the Hood is white \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eResin-Chem with removable interior access panels on both \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003esides. Removable exterior side panels provide easy access \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eto fixtures and their service lines.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv data-canvas-width=\"\"\u003e\n\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eThe interior of the Add Air Fume Hood is brightly lit by a \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003emaximum width dual fluorescent tube light fixture. The fixture \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eis mounted behind a sealed safety glass panel to isolate the \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003efixture from corrosive fumes and flammable vapors.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eReplacement of fluorescent tubes is accomplished from the \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eexterior top front of the Fume Hood superstructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eChoose from the variety of optional service fixtures available \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003efrom BMC. Service fixture and electrical outlet types and \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003elocations are to be specified by the customer to fit each \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eparticular application. Mounting holes are provided in the \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003esuperstructure for final on-site installation of optional equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cspan style=\"\" font-family: arial font-size: small\u003eFume Hood Superstructures are available in widths from 48\"\" to 96\"\" , including BMC's unique 84\"\" wide model. Servic\u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ee and \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eelectrical fixtures shown are optional and must be ordered separately.\u003c\/span\u003e\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782107963,"sku":"80-2202-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2202_2d1f0d36-b355-4fb8-a928-77478190dbb2.png?v=1784701155"},{"product_id":"primeaire-bypass-fume-hood-available-in-various-sizes-with-multiple-options","title":"PrimeAire ByPass Fume Hood, Available in Various Sizes with Multiple Options","description":"\u003cp\u003e\u003cstrong\u003ePrime Industries® Airfoil Bypass Fume Hood\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eContinuous air flow across the work surface of the Airfoil Bypass Fume Hood exhausts potentially hazardous vapors safely away from the work environment, even with the sash closed!\u003c\/p\u003e\n\u003cp\u003eThe Airfoil Bypass Fume Hood features an internal bypass opening located above the sash allowing for a constant exhaust volume while maintaining the face velocity. In operation, the bypass works automatically, in conjunction with the hood sash. The bypass adjustment is made as the sash is opened and closed creating a relatively constant face velocity regardless of sash position.\u003c\/p\u003e\n\u003cp\u003eThe Bypass Fume Hood comes equipped with a full view sash providing an unobstructed view of the Hood interior work area. The sash, a glazed 7\/32 in. thick laminated safety glass is provided with a full width flush pull. A counterweight provides for one finger operation of the sash at any position. The entrance of the Hood is framed with inward-angled members. This angled frame works to minimize turbulence and provide smooth movement of air into the Hood, resulting in a more efficient operation of the Fume Hood at face velocities ranging from 60 to 150 FPM. A lower airfoil sash stop maintains a 1 in. space (below closed sash) that allows air to flow continuously across the work surface inside the Hood. Double wall construction of the Hood superstructure allows for easy installation of service fixtures and routing of interior plumbing and electrical lines. The interior of the Airfoil Bypass Fume Hood is white “Resin-Chem.” Removable access panels on both interior sides of the Hood are standard features. The exterior superstructure side panels are also removable for easy access to service fixtures and supply lines.\u003c\/p\u003e\n\u003cp\u003eA maximum width, two tube fluorescent light fixture, complete with tubes, is provided with the Airfoil Bypass Fume Hood. The light fixture is mounted above a sealed safety glass panel isolating it from corrosive fumes and hazardous vapors. Tube lights are easily replaced through the top front of the Fume Hood superstructure.\u003c\/p\u003e\n\u003cp\u003eA variety of optional service fixtures are available from for installation in the Bypass Fume Hood. Our representatives work closely with customers in specifying the type of fixtures and electrical receptacles required.\u003c\/p\u003e\n\u003cp\u003eFume Hood Superstructures are available in widths from 48in. to 96in. , including BMC's unique 84in. wide model. Service and electrical fixtures shown are optional and must be ordered separately.\u003c\/p\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782140731,"sku":"80-2256-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256.png?v=1784701156"},{"product_id":"airfoil-bypass-fume-hood-60-in-wide-prime-industries-b606","title":"Airfoil Bypass Fume Hood, 60 in. Wide, Prime Industries, B606","description":"\u003cp\u003e\u003cstrong\u003ePrime Industries® Airfoil Bypass Fume Hood, 60 in. W, B606\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous air flow across work surface of Airfoil Bypass Fume Hood exhaust potentially hazardous vapors safely away from work environment even whe sash is closed\u003c\/li\u003e\n\u003cli\u003eInternal bypass opening located above sash allows for constant exhaust volume while maintaining face velocity\u003c\/li\u003e\n\u003cli\u003eBypass works automatically in conjunction with sash — adjustment is made as sash is opened or closed creating relatively constant face velocity\u003c\/li\u003e\n\u003cli\u003eEquipped with full view sash for unobstructed view of hood interior\u003c\/li\u003e\n\u003cli\u003eSash is glazed 7\/32 in. thick laminated safety glass provided with full width flush pull\u003c\/li\u003e\n\u003cli\u003eCounterweight provide of easy one finger operation of sash\u003c\/li\u003e\n\u003cli\u003eEntrance of hood is framed with inward-angled members which minimizes turbulence to provide smooth movement of air into hood resulting in more efficient operation at face velocities ranging from 60 to 150 FPM\u003c\/li\u003e\n\u003cli\u003eLower sash top maintains 1 in. space below closed sash allowing air to flow constantly across work surface in hood\u003c\/li\u003e\n\u003cli\u003eDouble wall construction of hood superstructure allows easy installation and routing of interior plumbing and electrical lines\u003c\/li\u003e\n\u003cli\u003eInterior is made of white \"Resin-Chem\"\u003c\/li\u003e\n\u003cli\u003eRemovable access panels on both interior side of hood are standard\u003c\/li\u003e\n\u003cli\u003eExterior superstructure side panels removable for easy access to service fixtures and supply lines\u003c\/li\u003e\n\u003cli\u003eMaximum width, two tube fluorescent light fixture with tubes mounted above a sealed safety glass panel isolating it from corrosive fumes and hazardous vapors\u003c\/li\u003e\n\u003cli\u003eTube lights are easily replaceable through the top front of hood superstructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782206267,"sku":"80-2256-04-EA","price":5313.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256-04_88d42095-7b60-47ca-a1d4-934db7d081c2.png?v=1784701158"},{"product_id":"airfoil-bypass-fume-hood-48-in-w-prime-industries-b604","title":"Airfoil Bypass Fume Hood, 48 in. W, Prime Industries, B604","description":"\u003cp\u003e\u003cstrong\u003ePrime Industries® Airfoil Bypass Fume Hood, 48 in. W, B604\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous air flow across work surface of Airfoil Bypass Fume Hood exhaust potentially hazardous vapors safely away from work environment even whe sash is closed\u003c\/li\u003e\n\u003cli\u003eInternal bypass opening located above sash allows for constant exhaust volume while maintaining face velocity\u003c\/li\u003e\n\u003cli\u003eBypass works automatically in conjunction with sash — adjustment is made as sash is opened or closed creating relatively constant face velocity\u003c\/li\u003e\n\u003cli\u003eEquipped with full view sash for unobstructed view of hood interior\u003c\/li\u003e\n\u003cli\u003eSash is glazed 7\/32 in. thick laminated safety glass provided with full width flush pull\u003c\/li\u003e\n\u003cli\u003eCounterweight provide of easy one finger operation of sash\u003c\/li\u003e\n\u003cli\u003eEntrance of hood is framed with inward-angled members which minimizes turbulence to provide smooth movement of air into hood resulting in more efficient operation at face velocities ranging from 60 to 150 FPM\u003c\/li\u003e\n\u003cli\u003eLower sash top maintains 1 in. space below closed sash allowing air to flow constantly across work surface in hood\u003c\/li\u003e\n\u003cli\u003eDouble wall construction of hood superstructure allows easy installation and routing of interior plumbing and electrical lines\u003c\/li\u003e\n\u003cli\u003eInterior is made of white \"Resin-Chem\"\u003c\/li\u003e\n\u003cli\u003eRemovable access panels on both interior side of hood are standard\u003c\/li\u003e\n\u003cli\u003eExterior superstructure side panels removable for easy access to service fixtures and supply lines\u003c\/li\u003e\n\u003cli\u003eMaximum width, two tube fluorescent light fixture with tubes mounted above a sealed safety glass panel isolating it from corrosive fumes and hazardous vapors\u003c\/li\u003e\n\u003cli\u003eTube lights are easily replaceable through the top front of hood superstructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782239035,"sku":"80-2256-05-EA","price":4553.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256-05_25903362-0ed8-4461-aff9-65422847b728.png?v=1784701159"},{"product_id":"prime-aire-airfoil-add-air-fume-hood-48-in-type-304-prime-industries-b-624","title":"Prime-Aire Airfoil Add Air Fume Hood, 48 in, Type 304, Prime Industries, B-624","description":"\u003cp\u003e\u003cstrong\u003ePrime Industries® Prime-Aire™ Airfoil Add Air Fume Hood, 48 in, Type 304, B-624\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides added economy through use of front-mounted \"add air plenum\" that can supply up to 70 percent of total air volume requirement from outside source\u003c\/li\u003e\n\u003cli\u003eSuperstructure entrance framed with inward angled members that minimize turbulence and provide smooth movement of air into hood\u003c\/li\u003e\n\u003cli\u003eDesign allows for efficient operation of hood with at face velocities ranging from 60 to 150 FPM\u003c\/li\u003e\n\u003cli\u003eBult-in bypass feature above hood sash works to maintain relatively constant face velocity at any sash height\u003c\/li\u003e\n\u003cli\u003eAdd Air Plenum utilizes series of diffusers and louvers to provide uniform flow of supply air to hood face\u003c\/li\u003e\n\u003cli\u003eEquipped with full view laminated safety glass sash with full width flush pull and counterweight for easy operation\u003c\/li\u003e\n\u003cli\u003eLower airfoil acts as sash stop that provides 1 in. space for air to continuously flow into hood and across work surface\u003c\/li\u003e\n\u003cli\u003eDouble wall construction of superstructure provides adequate space on both side os hood for installation of service fixtures and routing plumbing\/electrical lines\u003c\/li\u003e\n\u003cli\u003eLining of interior work are of hood is white resin-Chem with removable interior access panels on both sides\u003c\/li\u003e\n\u003cli\u003eRemovable exterior side panels provide easy acces to fixtures and service lines\u003c\/li\u003e\n\u003cli\u003eInterior of hood is brightly lit by maximum width dual flouorescent tube light fixture that is mounted behind a sealed safety glass panel to isolate fixture from corrosive fumes and flammable vapors\u003c\/li\u003e\n\u003cli\u003eFluorescent tube replacement accomplished via exterior top front access panel\u003c\/li\u003e\n\u003cli\u003eVariety of optional service fixtures available from Prime-Aire™ with types and location customer specification\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782402875,"sku":"80-2256-20-EA","price":10083.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256-20_105fed9c-25ea-47c7-ba2f-6e5d19c5aeeb.png?v=1784701161"},{"product_id":"primeaire-perchloric-acid-fume-hood-available-in-various-sizes-with-multiple-options","title":"PrimeAire Perchloric Acid Fume Hood, Available in Various Sizes with Multiple Options","description":"\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003e\u003c\/span\u003e\u003cspan style=\"\" small font-size:=\"\"\u003e\u003c\/span\u003e\u003cdiv data-canvas-width=\"\"\u003e\n\u003cspan style=\"\" font-size: small\u003eThis Fume Hood is specifically designed for the use of \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eperchloric acid. A coved stainless steel liner with integral \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003ework surface, an internal water wash down system and \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003ewater collection trough provide for detailed cleaning of the \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eHood interior. In addition, the interior baffles are also \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eremovable for cleaning to prevent the dangerous build-up \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eof perchlorates.\u003c\/span\u003e\n\u003c\/div\u003e\u003cdiv data-canvas-width=\"\"\u003e\u003c\/div\u003e\u003cspan style=\"\" small font-size:=\"\"\u003e\u003c\/span\u003e\u003cdiv data-canvas-width=\"\"\u003e\n\u003cp\u003e\u003cspan style=\"\" font-size: small\u003eThe Perchloric Acid Fume Hood has an internal bypass \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003elocated above the sash. The bypass operates automatically, \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eopening when the sash is closed and closing as the sash is \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eraised. The bypass provides for a relatively constant face \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003evelocity at any sash position.  \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eThe sash frame and lower airfoil are constructed of type \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003e316 stainless steel. The sash is glazed with 7\/32\"\" thick \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003elaminated safety glass and has full width pull and \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003ecounterweight for easy up\/down operation. In the closed \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eposition, the lower airfoil acts as a sash stop providing a 1\"\" \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003espace for air to continuously sweep the work surfaces.  \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eThe interior liner, work surface and baffles are also con\u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003estructed of type 316 stainless steel. A wash down spray bar \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eis located behind the upper baffle for continuous cleaning \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003ebehind the baffles. A full width trough is located below the \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003elower baffle to collect the wash down water from both the \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eHood and ductwork. \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eDouble wall construction of the superstructure allows for \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003einstallation of service fixtures and routing of interior \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003eplumbing and electrical lines. Access for installation and \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003emaintenance of service fixtures is obtained by removing \u003c\/span\u003e\u003cspan style=\"\" font-size: small\u003ethe exterior side panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial\u003eA two tube fluorescent light fixture illuminates the interior of \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003ethe Perchloric Acid Fume Hood. The fixture is mounted behind a \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003esealed safety glass panel to isolate the fixture from corrosive \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003efumes and flammable vapors. Replacement of fluorescent tubes \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003eis accomplished from the exterior top front of the Fume Hood \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003esuperstructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-canvas-width=\"\"\u003eFume Hood Superstructures are available in widths from 48\"\" to 96\"\" , including BMC's unique 84\"\" wide model.  Service and electrical fixtures shown are optional and must be ordered separately. \u003cspan style=\"\" font-family: arial\u003eA variety of optional service fixtures are available from BMC.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003eThe location of the fixtures must be specified for accurate \u003c\/span\u003e\u003cspan style=\"\" font-family: arial\u003ecutting of the mounting holes located in the Fume Hood lining.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782468411,"sku":"80-2256-PERC-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256-PERC_9e58d85a-338a-419c-835c-5cc18dec6cec.png?v=1784701162"},{"product_id":"primeaire-variable-air-volume-fume-hood-available-in-various-sizes-with-multiple-options","title":"PrimeAire Variable Air Volume Fume Hood, Available in Various Sizes with Multiple Options","description":"\u003cp data-canvas-width=\"\"\u003e\u003c\/p\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003eThe Variable Volume Fume Hood is specifically designed \u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003efor use with exhaust control systems provided by other \u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003emanufacturers that monitor and control the amount of air \u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003ebeing exhausted from the Hood. The use of these devices \u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003ewill maintain a constant face velocity and greatly reduce \u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003ethe operating cost of the Fume Hood.\u003c\/span\u003e\u003cspan style=\"\" arial small font-family:=\"\" font-size:=\"\"\u003e\u003c\/span\u003e\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eA lintel at the upper front of the superstructure restricts the \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eHood air intake to the front sash opening. By incorporating \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eany one of a number of commercially available VAV \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003econtrols, the exhaust volume of the Hood can be varied to \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003emaintain a specified face velocity regardless of sash \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eposition.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eThe full view sash provides a clear, unobstructed view of \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ethe work surface and when fully opened, allows easy \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eaccess to all areas of the Hood interior. The sash is \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ecounterweighted for easy up\/down operation and is made \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eof 7\/32\"\" laminated safety glass with a full width flush pull.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eThe lower airfoil acts as a sash stop designed to provide a \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e1\"\" gap (with sash closed) allowing air to continuously sweep \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ethe countertop of the Fume Hood.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eDouble side wall Hood construction provides \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eadequate space for mounting service fixtures. The interior \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e“Resin-Chem” lining has removable access panels on \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eeither side providing easy access for installation and \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003emaintenance of service and electrical fixtures. Both \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eexterior side panels of the Hood superstructure are also \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eremovable for access to lines.\u003c\/span\u003e\u003c\/p\u003e\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eA twin tube fluorescent light fixture provides illumination \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eof the Hood's interior surfaces. The fixture is recessed into \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ethe interior Hood ceiling and protected behind a sealed safety \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eglass panel away from hazardous vapors and corrosive \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003efumes. Tubes (included with Hood purchase) are easily \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003ereplaced from the outside of the Hood superstructure.  \u003c\/span\u003e\u003c\/p\u003e\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eA variety of optional service fixtures are available from\u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003e for installation in the Variable Volume Fume Hood.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eMounting holes for fixtures and electrical receptacles are \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003epre-cut and capped when fixtures are not required.\u003c\/span\u003e\u003c\/p\u003e\u003cp data-canvas-width=\"\"\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eFume Hood Superstructures are available in widths from 48\"\" to 96\"\" , including BMC's unique 84\"\" wide model.  \u003c\/span\u003e\u003cspan style=\"\" font-family: arial font-size: small\u003eService and electrical fixtures shown are optional and must be ordered separately.\u003c\/span\u003e\u003c\/p\u003e\u003cp data-canvas-width=\"\"\u003e\u003c\/p\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782501179,"sku":"80-2256-VAV-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2256-VAV_40befb7f-05cd-4a1d-8ed7-582d4844544b.png?v=1784701164"},{"product_id":"6-ft-protector-premier-laboratory-hood-with-built-in-exhaust-blower-2-service-fixtures-and-1-electrical-duplex-labconco-100600042","title":"6 ft. Protector Premier Laboratory Hood with Built-in Exhaust Blower, 2 Service Fixtures and 1 Electrical Duplex, Labconco, 100600042","description":"\u003cp\u003e\u003cstrong\u003eLabconco® 6 ft. Protector Premier Laboratory Hood with Built-in Exhaust Blower, 2 Service Fixtures and 1 Electrical Duplex, 100600042\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eBy-pass airflow design\u003c\/li\u003e \u003cli\u003eEco-Foil™ Air Foil reduces energy consumption by 7-10% compared to flat air foils while its aerodynamic curve allows air to sweep the work surface for maximum containment. Clean-Sweep™ openings pull inflow air from under the air foil forcing air into non-turbulent air streams.\u003c\/li\u003e \u003cli\u003eCord-Keeper™ Slots on left and right side of air foil keep electrical cords out of the way\u003c\/li\u003e \u003cli\u003eGlacier white powder-coated steel exterior is durable and corrosion-resistant\u003c\/li\u003e \u003cli\u003eOne-piece molded fiberglass liner and pre-set baffle(s) with flame spread less than 25 per ASTM E84\u003c\/li\u003e \u003cli\u003eTempered safety glass vertical-rising sash with powder-coated sash handle and Clean-Sweep™ openings\u003c\/li\u003e \u003cli\u003e37.5 (95.3 cm) high sightline from the work surface to header panel allows taller users comfortable viewing while standing\u003c\/li\u003e \u003cli\u003eRemovable front and side panels, and front service access panels for access to plumbing and electrical wiring\u003c\/li\u003e \u003cli\u003ePre-wired LED lighting with vapor-proof design and ADA-compliant light and blower switches. Lighting rated to 50,000 hours. (Not on models with built-in explosion proof blower)\u003c\/li\u003e \u003cli\u003eOn models for use with remote blower, 12.8 ID exhaust connection(s)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eBuilt-In Blower Models Feature\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eBuilt-in belt-driven, corrosion-resistant exhaust blower with adjustable sheave, molded thermoplastic housing and non-sparking, coated aluminum impeller\u003c\/li\u003e \u003cli\u003e10.8 ID exhaust connection on 4' models; 12.8 ID exhaust connection on 5' and 6' models\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eFixtured Models May Feature\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eTwo pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side wit copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided.\u003c\/li\u003e \u003cli\u003eOne pre-wired GFCI electrical duplex receptacle on lower right side and, on 8' models only, one additional pre-wired GFCI electrical duplex receptacle on lower left side\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eRequired Accessories (Not Included)\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eRemote blower (except for built-in blower models)\u003c\/li\u003e \u003cli\u003eDuctwork\u003c\/li\u003e \u003cli\u003eSpillStopper™ Work Surface\u003c\/li\u003e \u003cli\u003eBase cabinet or stand\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eService Fixture Kits (some models include service fixtures)\u003c\/li\u003e \u003cli\u003eElectrical Duplex Kits (some models include electrical duplex)\u003c\/li\u003e \u003cli\u003eGuardian Airflow Monitor Kits\u003c\/li\u003e \u003cli\u003eDistillation Grid Kits\u003c\/li\u003e \u003cli\u003eSash Stop Kits\u003c\/li\u003e \u003cli\u003eCeiling Enclosures and Rear Finish Panel Kits\u003c\/li\u003e \u003c\/ul\u003e","brand":"Labconco","offers":[{"title":"EA (1)","offer_id":51110782533947,"sku":"80-2258-06-EA","price":19510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2258-06_d4b95ce5-dc82-4d4a-bee2-afde756fcfad.png?v=1784701166"},{"product_id":"guardian-airflow-monitor-9413300","title":"Guardian Airflow Monitor, 9413300","description":"\u003cp\u003e\u003cstrong\u003eLabconco® Guardian Airflow Monitor, 9413300\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSense and alert operator to low airflow conditions\u003c\/li\u003e \u003cli\u003eFrom monitor's face plate, user can easily select and calibrate set point between 30 and 250 fpm using velocity meter and screwdriver\u003c\/li\u003e \u003cli\u003eAudible\/visual alarm\u003c\/li\u003e \u003cli\u003eIncludes night setback, external alarm and alarm mute functions\u003c\/li\u003e \u003cli\u003eFlushmount design on Protector ClassMate, Premier, XStream and XL Fume Hoods (up to 8' models)\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eCompatible with Labconco Hood Models:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eProtector Premier Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XL Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XStream Laboratory Hoods\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e","brand":"Labconco","offers":[{"title":"EA (1)","offer_id":51110782665019,"sku":"80-2445-02-EA","price":1420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2445-02.png?v=1784701169"},{"product_id":"cold-water-cw-gooseneck-fixture-kit-for-labconco-hoods-labconco-9827900","title":"Cold Water (CW) Gooseneck Fixture Kit for Labconco Hoods, Labconco, 9827900","description":"\u003cp\u003e\u003cstrong\u003eLabconco® Cold Water (CW) Gooseneck Fixture Kit for Labconco Hoods, 9827900\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e Features:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eKit includes one remotely-controlled gooseneck with brass valve and 0.375 diameter copper tubing and green fixture knob\u003c\/li\u003e \u003cli\u003eInlet tubing is not included\u003c\/li\u003e \u003cli\u003eIncludes green epoxy-coated brass rigid\/swivel gooseneck\u003c\/li\u003e \u003cli\u003eMaximum flow rate of 3.5 GPM (13.2 LPM)\u003c\/li\u003e \u003cli\u003eMaximum working pressure of 40 psi\u003c\/li\u003e \u003cli\u003eMount on left or right side of any Protector Premier, XStream, PVC, Stainless Steel, XL or XLE Laboratory Hood with 24 to 30 interior depth\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eApplicable Products:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eProtector Premier Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector PVC Acid Digestion Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector PVC Perchloric Acid Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector Radioisotope Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector Perchloric Acid Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XL Benchtop Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XL Floor-Mounted Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XLE Laboratory Hoods\u003c\/li\u003e \u003cli\u003eProtector XStream Laboratory Hoods\u003c\/li\u003e \u003c\/ul\u003e","brand":"Labconco","offers":[{"title":"EA (1)","offer_id":51110783451451,"sku":"80-2556-31-EA","price":1025.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2556-31_0c84c05a-f7ff-4562-803d-a045d6c8337f.png?v=1784701189"},{"product_id":"tel-uk-digital-air-flow-monitor-for-hoods-0-to-1000-ft-min-afa1000-1","title":"TEL-UK Digital Air Flow Monitor for Hoods, 0 to 1000 ft\/min, AFA1000\/1","description":"\u003cp\u003e\u003cstrong\u003eTEL-UK® Digital Air Flow Monitor for Hoods, 0 to 1000 ft\/min, AFA1000\/1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe AFA1000\/1 is a digital airflow monitor designed for applications where pushbutton functions are not required\u003c\/li\u003e\n\u003cli\u003eAvailable with range of remote unique airflow sensors used to measure face velocities or duct velocities\u003c\/li\u003e\n\u003cli\u003eAvailable fully flush (MK2) or semi flush (MK3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 95%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameters\u003c\/td\u003e\n\u003ctd\u003eAFA1000\/1 MK2\u003c\/td\u003e\n\u003ctd\u003eAFA1000\/1 MK3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Range\u003c\/td\u003e\n\u003ctd\u003e0-2.00m\/sec (30-400fpm) remote SM6 or ILS Air Flow Sensor\u003c\/td\u003e\n\u003ctd\u003e0-2.00m\/sec (30-400fpm) remote SM6 or ILS Air Flow Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Set up\u003c\/td\u003e\n\u003ctd\u003e2 Point velocity calibration with on screen instructions\u003c\/td\u003e\n\u003ctd\u003e2 Point velocity calibration with on screen instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Face Velocity\u003c\/td\u003e\n\u003ctd\u003e+-5%\u003c\/td\u003e\n\u003ctd\u003e+-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow Sensor \u003c\/td\u003e\n\u003ctd\u003eIntegral Airflow Sensor or remote SM6 \/ ILS\u003c\/td\u003e\n\u003ctd\u003eIntegral Airflow Sensor or remote SM6 \/ ILS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output \u003c\/td\u003e\n\u003ctd\u003e3 Configurable outputs\u003c\/td\u003e\n\u003ctd\u003e3 Configurable outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Delay Times \u003c\/td\u003e\n\u003ctd\u003eConfigurable 0-60 seconds\u003c\/td\u003e\n\u003ctd\u003eConfigurable 0-60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Input \u003c\/td\u003e\n\u003ctd\u003e3 Configurable inputs\u003c\/td\u003e\n\u003ctd\u003e3 Configurable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCom Port\u003c\/td\u003e\n\u003ctd\u003eRS485 com port Modbus RTU and BACnet\u003c\/td\u003e\n\u003ctd\u003eRS485 com port Modbus RTU and BACnet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSash High Alarm \u003c\/td\u003e\n\u003ctd\u003eYes with alarm repeat\u003c\/td\u003e\n\u003ctd\u003eYes with alarm repeat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNight Setback \u003c\/td\u003e\n\u003ctd\u003eYes – relay input\u003c\/td\u003e\n\u003ctd\u003eYes – relay input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay \u003c\/td\u003e\n\u003ctd\u003eDigital velocity display fpm \/ m\/sec 3 x LED’s (Safe\/Caution\/Alarm)\u003c\/td\u003e\n\u003ctd\u003eDigital velocity display fpm \/ m\/sec 3 x LED’s (Safe\/Caution\/Alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Indication \u003c\/td\u003e\n\u003ctd\u003eRed LED with Audible alarm \u003c\/td\u003e\n\u003ctd\u003eRed LED with Audible alarm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorn Silence\u003c\/td\u003e\n\u003ctd\u003eTemporary or Permanent\u003c\/td\u003e\n\u003ctd\u003eTemporary or Permanent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFully flush\u003c\/td\u003e\n\u003ctd\u003eSemi Flush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor Operating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e13 to 30 degrees C (55 to 86 degrees F)\u003c\/td\u003e\n\u003ctd\u003e13-30 degrees C (55-86 degrees F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow sensor Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e15 to 25 degrees C (59 to 77 degrees F)\u003c\/td\u003e\n\u003ctd\u003e15-25 degrees C (59-77 degrees F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow sensor Working Temperature\u003c\/td\u003e\n\u003ctd\u003eAmbient +25 degrees C\/77 degrees F\u003c\/td\u003e\n\u003ctd\u003eAmbient +25 degrees C\/77 degreesF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Listings\u003c\/td\u003e\n\u003ctd\u003eCE RoHS\u003c\/td\u003e\n\u003ctd\u003eCE RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area (Remote Airflow Sensor)\u003c\/td\u003e\n\u003ctd\u003eGas group IIC; Temp Class T6; With Atex certified I.S Zener Barriers\u003c\/td\u003e\n\u003ctd\u003eGas group IIC; Temp Class T6; With Atex certified I.S Zener Barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110988480827,"sku":"90-9059-31-EA","price":1450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-9059-31_ea244ad9-5c25-4e56-b56f-75bbfaa938f3.png?v=1784706268"},{"product_id":"hood-4-ft-protector-premiere-with-built-in-exhaust-blower-2-service-fixtures-and-1-electrical-duplex-labconco-100400042","title":"Hood, 4 ft Protector Premiere with Built-In Exhaust Blower, 2 Service Fixtures and 1 Electrical Duplex, LabConco, 100400042","description":"\u003cp\u003e\u003cstrong\u003eLabConco® Hood, 4 ft Protector Premiere® with Built-In Exhaust Blower, 2 Service Fixtures and 1 Electrical Duplex, 100400042\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBy-pass airflow design\u003c\/li\u003e\n\u003cli\u003eEco-Foil™ Air Foil reduces energy consumption by 7-10% compared to flat air foils while its aerodynamic curve allows air to sweep the work surface for maximum containment. Clean-Sweep™ openings pull inflow air from under the air foil forcing air into non-turbulent air streams.\u003c\/li\u003e\n\u003cli\u003eCord-Keeper™ Slots on left and right side of air foil keep electrical cords out of the way\u003c\/li\u003e\n\u003cli\u003eGlacier white powder-coated steel exterior is durable and corrosion-resistant\u003c\/li\u003e\n\u003cli\u003eOne-piece molded fiberglass reinforced polyester(FRP) liner and pre-set baffle(s) with flame spread less than 25 per ASTM E84\u003c\/li\u003e\n\u003cli\u003eTempered safety glass vertical-rising sash with powder-coated sash handle and Clean-Sweep™ openings\u003c\/li\u003e\n\u003cli\u003e37.5 in. (95.3 cm) high sightline from the work surface to header panel allows taller users comfortable viewing while standing\u003c\/li\u003e\n\u003cli\u003eRemovable front and side panels, and front service access panels for access to plumbing and electrical wiring\u003c\/li\u003e\n\u003cli\u003ePre-wired LED lighting with vapor-proof design and ADA-compliant light and blower switches. Lighting rated to 50,000 hours. (Not on models with built-in explosion proof blower)\u003c\/li\u003e\n\u003cli\u003eOn models for use with remote blower, 12.8 in. ID exhaust connection(s)\u003c\/li\u003e\n\u003cli\u003eBuilt-in belt-driven, corrosion-resistant exhaust blower with adjustable sheave, molded thermoplastic housing and non-sparking, coated aluminum impeller\u003c\/li\u003e\n\u003cli\u003e10.8 in. ID exhaust connection on 4 ft models; 12.8 in. ID exhaust connection on 5 and 6 ft models\u003c\/li\u003e\n\u003cli\u003ePre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gass and lower leff side with copper tubing for cold water - components for converting either or both fixtures to air and vacuum are provided, no inlet tubing provided\u003c\/li\u003e\n\u003cli\u003ePre-wired GFCI electrical duplex receptacle on lower right side (Additional GFCI fixture on lower left side of 8 ft models only)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labconco","offers":[{"title":"EA (1)","offer_id":51110782599483,"sku":"80-2258-14-EA","price":15790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2258-14.png?v=1784701167"},{"product_id":"airflow-monitor-digital-for-fume-hoods-tel-afa1000-1","title":"TEL Airflow Monitor, Digital Alarm Unit for Fume Hoods, Prime Industries Inc, AFA1000\/1","description":"\u003cp\u003e\u003cstrong\u003ePrime Industries Inc® TEL® Airflow Monitor, Digital Alarm Unit for Fume Hoods, AFA1000\/1\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSystem includes in-line airflow sensor, AFA1000 Alarm unit and AC power supply\u003c\/li\u003e\n\u003cli\u003eDisplay operates through software allowing generation of figures, wording and Icons\u003c\/li\u003e\n\u003cli\u003e3 programmable airflow alarms\u003c\/li\u003e\n\u003cli\u003eShows fume hood face velocity in m\/sec or fpm when enabled or alternatively, with no velocity reading but showing LOW AIR \/ NORMAL as continuous display and these are configured via keypad\u003c\/li\u003e\n\u003cli\u003eEvent timeline can be displayed that shows events that have occurred during past hour or bar graph representing face velocity\u003c\/li\u003e\n\u003cli\u003eAlarm can be audible or mute (when muted HORN Icon with line through it will be on display)\u003c\/li\u003e\n\u003cli\u003ePossible configurations can include Sash high, External alarm, Low air, High air, Set-back and Displayed\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Prime Industries Inc","offers":[{"title":"EA (1)","offer_id":51110782730555,"sku":"80-2445-10-EA","price":1790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-2445-10_8941f526-2172-4ec9-a84d-e5a532d0b1d5.png?v=1784701170"},{"product_id":"spill-stopper-work-surface-4-ft-labconco-9500400","title":"Spill Stopper Work Surface, 4 ft. Labconco, 9500400","description":"\u003cp\u003e\u003cstrong\u003eLabconco® Spill Stopper Work Surface, 4 ft., 9500400\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNo cup sink cut out\u003c\/li\u003e\n\u003cli\u003eFor use with Protector Premier and Premier XI Laboratory Hoods\u003c\/li\u003e\n\u003cli\u003eIdeal top surface for Acid storage cabinet\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Labconco","offers":[{"title":"EA (1)","offer_id":51110783910203,"sku":"80-3002-23-EA","price":1890.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/80-3002-23_17f70806-d6e8-40ab-9507-8349383050ac.png?v=1784701201"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/404.jpg?v=1761775641","url":"https:\/\/preiser.com\/collections\/hoods.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}