{"title":"ISE\/pH Meters (Combo)","description":"\u003cp\u003eISE\/pH Meters (Combination)\u003c\/p\u003e","products":[{"product_id":"ise-ph-meter-laboratory-research-grade-two-channel-benchtop-ph-mv-ise-probes-solutions-hanna-instruments-hi5222-01","title":"ISE\/pH Meter, Laboratory Research Grade Two Channel Benchtop pH\/mV\/ISE, Probes, Solutions, Hanna Instruments, HI5222-01","description":"\u003cp\u003e\u003c\/p\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eHanna® Laboratory Research Grade Two Channel Benchtop pH\/mV Meter with pH Electrode and Temperature Probe, 0.001 pH Resolution, HI5222-01\u003c\/span\u003e\u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eHighly customizable user interface\u003c\/strong\u003e—includes showing measurements in various modes with or without GLP information, real-time graphing, logging data, adjustable calibration stability criteria (fast, moderate, and accurate), programmable alarm limits (inside or outside)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eColor graphic LCD\u003c\/strong\u003e—on-screen help, graphic and custom color configurations, real-time graphing, virtual keys for intuitive user interface\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eBuilt in barometer\u003c\/strong\u003e—provides pressure compensation for all DO measurements via built-in pressure transducer (can be calibrate to a single point)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eCapacitive touch\u003c\/strong\u003e—sensitive touch buttons for accurate keystrokes while navigating menus and screens; four dedicated keys for routine operations including calibration and switching modes plus four virtual keys that change based on use; no worry of clogged buttons \u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eTwo Galvanically Isolated pH\/ORP\/ISE Channels\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eChoice of calibration\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options available for calibrating up to 5 points from a selection of 8 standard buffers and up to 5 custom buffers\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—user can view calibration data and calibration expiration at touch of a key; includes date, time, buffer\/standards used, and slope characteristcs; offset for pH electrodes also displayed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eCAL Check™—\u003c\/strong\u003ealerts user to potential problems during calibration of pH electrode; indicators include Electrode Dirty\/Broken, Buffer Contaminated, electrode response time and overall probe condition as a percentage based on offset and slope \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eISE Measurement with choice of calibration units\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e—choice for both calibration and readings for the following units of concentration: ppt, g\/L, mg\/mL, µg\/mL, ppb, \u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003eµg\/L,M, mol\/L, mmol\/L, %w\/v, and a user-defined unit\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eISE Measurement with Incremental Methods\u003c\/strong\u003e—known addition, known subtraction, analyte addition, and analyte subtraction incremental methods are pre-programmed; follow on-screen guided procedure; meter will perform the calculation automatically allowing for a higher level of accuracy to be obtained as compared to a direct ISE measurement\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eData logging\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—automatic, manual, and auto-hold logging \u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e(up to 100 lots with 50,000 records maximum\/lot with up to 100,000 total data points per channel)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e ; automatic logging features option to save data according to sampling period and interval\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eData transfer\u003c\/strong\u003e—transfer data to PC via USB cable and HI92000 (\u003cspan\u003e91-2599-11\u003c\/span\u003e) software (sold separately)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eContextual help\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e—\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ededicated Help key provides clear tutorial messages and on-screen directions to guide users through set-up and calibration; information displayed relative to setting or option being viewed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e—2 years for meter; 6 months for probes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003c\/p\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI1131B pH electrode (\u003cspan\u003e91-2698-24\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI7662-T temperature probe (\u003cspan\u003e91-5990-12\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI76404W electrode holder\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI70004P pH 4.01 buffer solution sachet (\u003cspan\u003e91-2704-04\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI70007P pH 7.01 buffer solution sachet (\u003cspan\u003e91-2704-07\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI70000P electrode cleaning solution sachet (2) (\u003cspan\u003e91-2704-11\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI7082 3.5M KCl electrolyte solution (30 mL) (\u003cspan\u003e91-2599-79\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e12 VDC adapter\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eInstruction Manual\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv style=\"text-align:\" center\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 579px; height: 1142px; border: 1px solid #0d026d;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #9a9aa2;\" rowspan=\"5\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003e- 2.0 to 20.0 pH; - 2.00 to 20.00 pH; - 2.000 to 20.000 pH\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1; 0.01; 0.001 pH\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy @ 25 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e (77 \u003cspan style=\"font-size: small;\"\u003e°F)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.1 pH; ± 0.01 pH; \u003cspan style=\"font-size: small;\"\u003e± 0.002 pH \u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 1 LSD\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature compensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003eAutomatic or manual from - 20 to 120.0 \u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #9a9aa2;\" rowspan=\"4\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003emV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 2000 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 mV\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.2 mV \u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 1 LSD\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRelative offset range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e± 2000 mV\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #9a9aa2;\" rowspan=\"3\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature  \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e- 20.0 to 120 °C; - 4.0 to 248 °F; 253.15 to 393.1 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy \u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.2 °C; ± 0.4 °F; ± 0.2 K \u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #9a9aa2;\" rowspan=\"4\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003eISE\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 x 10¯6 to 9.99 x 10¹º concentration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1; 0.1; 0.001 concentration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy @ \u003cspan style=\"font-size: small;\"\u003e25 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e (77 \u003cspan style=\"font-size: small;\"\u003e°F)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 0.5% (monovalent ions); \u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 1% (divalent ions)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration points\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic, up to 5 point calibration, seven fixed standard solutions available (0.01, 0.1, 1, 10, 100, 1000, 10000 choice of concentration) and five custom solutions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #9a9aa2;\" rowspan=\"11\"\u003e\n\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAdditional \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eElectrode\/Probe\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eHI1131B glass body pH electrode with BNC connector and 1 m (3.3') cable (included)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature probe\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eHI7662-T stainless steel temperature probe with 1 m (3.3') cable (included)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eGLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration data including date, time, buffers used, offset, and slope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eLogging \u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e100,000 data points; 100 lots with 50,000 records\/lot; \u003cbr\u003eInterval: settlable between 1 second and 180 minutes maximum log time; \u003cbr\u003eType: automatic, manual, AutoHold\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eInput channels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e2 - pH\/ORP\/ISE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50 \u003cspan style=\"font-size: small;\"\u003e°C (32 to 122 \u003cspan style=\"font-size: small;\"\u003e°F; 273 to 323 K);\u003cbr\u003eRelative Humidity Maximum 95% non-condensing\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePC connectvity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUSB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eDisplay\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eColor graphic LCD with on-screen help, graphing, and custom color configuation\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003ePower supply\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e12 VDC adapter (included)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eDimensions\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e160 x 231 x 94 mm (6.3 x 9.1 x 3.7\")\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e1.2 kg (2.64 lbs.)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111024984379,"sku":"91-2599-91-EA","price":1239.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2599-91_9be0acbd-46ac-4c30-b78e-c3977795862d.png?v=1784707080"},{"product_id":"fisherbrand-accumet-ap125-portable-ph-ion-mv-temperature-meter-kit","title":"Fisherbrand Accumet AP125 Portable pH\/Ion\/mV\/Temperature Meter Kit","description":"\u003cp\u003e\u003cstrong\u003eFisherbrand™ Accumet™ AP125 Portable pH\/Ion\/mV\/Temperature Meter Kit, 13-636-AP125\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged waterproof housing, IP67 rated\u003c\/li\u003e\n\u003cli\u003eLarge LCD with backlighting and plain-language text—easy to see and use\u003c\/li\u003e\n\u003cli\u003eIon concentration mode with choice of up to five of 10 preprogrammed calibration points\u003c\/li\u003e\n\u003cli\u003e-2.00 to +20.00 pH, 0.001 pH resolution\u003c\/li\u003e\n\u003cli\u003e0 to ±2000.0 mV, -5 ° to +100 °C\u003c\/li\u003e\n\u003cli\u003eAdjustable pH resolution\u003c\/li\u003e\n\u003cli\u003e200 data points internal memory\u003c\/li\u003e\n\u003cli\u003eDate\/time display to meet GLP requirements\u003c\/li\u003e\n\u003cli\u003eSlope display\u003c\/li\u003e\n\u003cli\u003eAuto Hold\u003c\/li\u003e\n\u003cli\u003eAuto-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeter\u003c\/li\u003e\n\u003cli\u003eAccumet combination refillable pH\/ATC electrode 13-620-AP50A\u003c\/li\u003e\n\u003cli\u003eRefill solution\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eSample bottles\u003c\/li\u003e\n\u003cli\u003epH calibration packets\u003c\/li\u003e\n\u003cli\u003e9V battery\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, Ion, mV, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength (Metric)\u003c\/td\u003e\n\u003ctd\u003eCable: 76 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003clabel\u003eAccuracy (mV)\u003c\/label\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to ±2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003clabel\u003eData Points\u003c\/label\u003e\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003clabel\u003eIP Rating\u003c\/label\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1012 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 6 points\u003cbr\u003e(depending on Buffer selection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Recognition\u003c\/td\u003e\n\u003ctd\u003eUSA: 2.00, 4.00, 7.00, 10.00, 12.00\n\u003cp\u003eNIST: 1.68, 4.01, 6.86, 9.18, 12.45\u003c\/p\u003e\n\u003cp\u003eEURO: 1.00, 3.00, 6.00, 8.00, 10.00, 13.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum and Maximum Slope Efficiency During Calibration\u003c\/td\u003e\n\u003ctd\u003e70 – 120%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV\/Relative mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV\/Relative mV Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIon Resolution\u003c\/td\u003e\n\u003ctd\u003e1 or 3 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIon Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% FS (monovalent)\u003cbr\u003e1% FS (divalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIon Calibration Points\u003c\/td\u003e\n\u003ctd\u003e2- 5 points (min. 2 pts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIon Buffer Values\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.5, 1, 2,\u003cbr\u003e5, 10, 50, 100, 500, 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum and Maximum Slope During Ion Calibration\u003c\/td\u003e\n\u003ctd\u003e15 to 90 mV \/decade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003clabel\u003eFor Use With (Application)\u003c\/label\u003e\u003c\/td\u003e\n\u003ctd\u003epH, Ion concentration, mV, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003clabel\u003eProduct Type\u003c\/label\u003e\u003c\/td\u003e\n\u003ctd\u003eMeter Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111026360635,"sku":"91-2600-25-EA","price":1854.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2600-25_63ab06c1-b2b2-4bfb-a18f-6b2eaa8b4f75.png?v=1784707111"},{"product_id":"myron-l-ultrapen-registered-pt4-free-chlorine-equivalent-temperature-pen-becker-equipment-pt4","title":"Myron L Ultrapen (Registered) PT4 Free Chlorine Equivalent \u0026 Temperature Pen, Becker Equipment, PT4","description":"\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMyron L® Ultrapen™ PT4 Free Chlorine Equivalent \u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e(FC E™)\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e  \u0026amp; Temperature Pen, PT4\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFast, accurate (± 0.3 ppm FC E) and easy-to-use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration with pH and ORP standard solutions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eMeasures the real, unaltered chemistry of the source water which is directly related to the actual disinfection power of the free available chlorine\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eProprietary sensor design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic temperature compensation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eRugged, reliable, water-proof, shock-resistant construction of aircraft grade aluminum fully protects inside electronics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eSimple, one-button operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature readout\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eIncludes high-capacity N-type battery\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eUser replaceable \u003cspan style=\"font-size: small;\"\u003eFC E™ sensor\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e1 year warranty excluding FC E™ sensor, 6 months on \u003cspan style=\"font-size: small;\"\u003eFC E™\u003c\/span\u003e sensor (battery not warranted)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eApplications:\u003c\/span\u003e\u003c\/strong\u003e\u003ctable style=\"width: 421px; height: 162px;\" border=\"0\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAgriculture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eHydroponics\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAquaculture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003ePharmaceutical\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eBoilers\/Cooling Towers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eWastewater\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eHorticulture\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003ePool\/Spa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eFood\/Beverage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eIrrigation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eReverse Osmosis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003ctable frame=\"border\" rules=\"all\" style=\"border-color: #000000; border-width: 1px;\" border=\"1\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"background-color: #c3dffc;\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eFC E\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 10.0 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003e0.01 ppm\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u0026lt; 5.00 ppm ± 0.3 ppm\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e≥ 5.00 ppm ± 0.5 ppm\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0-71 °C or 32-160 °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 °C or 0.1 °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.1 °C or ± 0.1 °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCompensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic in calibration modefrom 15 to 30 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eOperating\/Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0-55 °C or 32-131 °F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTime to Reading Stabilization\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e10 to 45 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower Consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eActive Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e37 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSleep Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e2 µA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eDimensions, Length x Diameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e17.15 x 1.59 cm or 6.75 x 0.625 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e50.4 g or 1.78 oz (without soaker cap \u0026amp; lanyard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCase Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003eAnodized aluminum with \u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003eUV protective coating\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eN-type, alkaline\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1.5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration Solutions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003epH 4, pH 7, pH 10, ORP80, ORP260, ORP470\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWater Resistance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eIP67 and NEMA 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCertification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\n\u003cspan style=\"font-size: small;\"\u003eEN61236-1: 2006 — Annex A: 2008; 0995\/5\/EC Annex III:\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003eElectrostatic discharge to case of insturment may cause PT3 to spontaneously power ON\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003eIn this case, the PT1 will power OFF after several seconds\u003c\/span\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111033438523,"sku":"91-2624-04-EA","price":288.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2624-04_c1c32bf8-e370-4512-a7d3-e26b757e2587.png?v=1784707321"},{"product_id":"dual-star-ph-ise-mv-orp-and-temperature-dual-channel-benchtop-meter-with-ross-ultra-glass-body-ph-electrode-atc-probe-solutions-and-standards-orion-2115001","title":"Dual Star pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter with ROSS Ultra Glass-Body pH Electrode, ATC Probe, Solutions and Standards, Orion, 2115001","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter with ROSS Ultra Glass-Body pH Electrode, ATC Probe, Solutions and Standards, Orion, 2115001\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo channels provides double measurement capabilities — record accurate and reliable pH, ion concentration, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in lab\u003c\/li\u003e\n\u003cli\u003eShows results of both channels simultaneously on its large, backlit display or toggle to single channel measurement showing\u003c\/li\u003e\n\u003cli\u003eCollect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable\u003c\/li\u003e\n\u003cli\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface\u003c\/li\u003e\n\u003cli\u003eEZ Startup menu facilitates quick and easy first-time meter setup — numeric keypad and menu-specific function keys speeds meter setup and data entry\u003c\/li\u003e\n\u003cli\u003eSelectable read modes include \u003cem\u003eAuto-Read\u003c\/em\u003e, \u003cem\u003eOn-Ready\u003c\/em\u003e, \u003cem\u003eAt Timed Intervals\u003c\/em\u003e, \u003cem\u003eContinuous\u003c\/em\u003e, \u003cem\u003eValue Change\u003c\/em\u003e \u003cem\u003ein Measurement\u003c\/em\u003e and \u003cem\u003eTimed\u003c\/em\u003e for a variety of measurement collection methods for different analytical methods\u003c\/li\u003e\n\u003cli\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/li\u003e\n\u003cli\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/li\u003e\n\u003cli\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/li\u003e\n\u003cli\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual Star Meter with Electrode Stand\u003c\/li\u003e\n\u003cli\u003eUniversal Power Adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (8102BNUWP) ROSS Ultra Glass Refillable pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e Stainless Steel ATC Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2668-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 810001) ROSS Storage Solution\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-910104\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 910104) pH 4.01 Buffer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-910107\u003c\/span\u003e\u003c\/span\u003e (Orion 910107) pH 7.00 Buffer\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-910110\u003c\/span\u003e\u003c\/span\u003e (Orion 910110) pH 10.01 Buffer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e1000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e2 to 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01, 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD with Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH (adjustable), 1.000 ISE (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eNumeric with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE\/mV\/RmV\/ORP\/Temperature Dual Channel Benchtop Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes \u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (8102BNUWP) ROSS Ultra pH electrode, \u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e 927007MD Orion ATC probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Temperature)\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSmart Stability and Smart Averaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184539238715,"sku":"91-2638-15-EA","price":2650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2638-15_25455745-d7d0-4d98-8355-d35437c695ba.png?v=1784707331"},{"product_id":"star-a214-ph-ise-mv-temperature-benchtop-meter-kit-with-stand-and-universal-power-adapter-orion-stara2140","title":"Star A214 pH\/ISE\/mV\/Temperature Benchtop Meter Kit, with Stand and Universal Power Adapter Orion STARA2140","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A214 pH\/ISE\/mV\/Temperature Benchtop Meter Kit, with Stand and Universal Power Adapter, STARA2140\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft keys update for easy selection\u003c\/li\u003e\n\u003cli\u003eSamples can be mixed without a stir plate with direct control of the Orion™ Star™ stirrer probe \u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion 096019), sold separately\u003c\/li\u003e\n\u003cli\u003eElectrode arm and newly designed probe holder included makes it easier to maintain and place probes into samples\u003c\/li\u003e\n\u003cli\u003eMeter works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable if table space is a problem\u003c\/li\u003e\n\u003cli\u003eMultilanguage interface supports English, Spanish, French, Italian, German and Chinese\u003c\/li\u003e\n\u003cli\u003eAUTO-READ locks in the stable reading on your screen, indicator alerts user when readings are stable and timed reading gathers data in specific time intervals\u003c\/li\u003e\n\u003cli\u003eMeter offers up to five point pH calibration with automatic recognition for USA\/NIST and DIN buffers\u003c\/li\u003e\n\u003cli\u003eISE can be used infrequently or multiple times every day with advanced features such as timed end point, linear point-to-point, nonlinear selectable auto-blank and low-concentration range stability\u003c\/li\u003e\n\u003cli\u003eUser can fix errors without a complete recalibration with the calibration editing function\u003c\/li\u003e\n\u003cli\u003eNonvolatile memory holds up to 2000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eUser can easily transfer data and keep meter software up-to-date with the USB and RS232 ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A214 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003eElectrode stand\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111033700667,"sku":"91-2638-67-EA","price":2030.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2638-67_cf721341-15d0-4160-bdca-0e22a056733e.png?v=1784707333"},{"product_id":"star-a214-ph-ise-mv-temperature-multiparameter-benchtop-meter-kit-with-stand-probes-solutions-orion-stara2145","title":"Star A214 pH\/ISE\/mV\/Temperature Multiparameter Benchtop Meter Kit, with Stand, Probes \u0026 Solutions, Orion STARA2145","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A214 pH\/ISE\/mV\/Temperature Multiparameter Benchtop Meter Kit, with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra™ Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 096019 Stirrer Probe; 810199 ROSS pH Buffer Kit, Orion STARA2145J\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft keys update for easy selection\u003c\/li\u003e\n\u003cli\u003eSamples can be mixed without a stir plate with direct control of the Orion™ Star™ stirrer probe \u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion 096019), sold separately\u003c\/li\u003e\n\u003cli\u003eElectrode arm and newly designed probe holder included makes it easier to maintain and place probes into samples\u003c\/li\u003e\n\u003cli\u003eMeter works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable if table space is a problem\u003c\/li\u003e\n\u003cli\u003eMultilanguage interface supports English, Spanish, French, Italian, German and Chinese\u003c\/li\u003e\n\u003cli\u003eAUTO-READ locks in the stable reading on your screen, indicator alerts user when readings are stable and timed reading gathers data in specific time intervals\u003c\/li\u003e\n\u003cli\u003eMeter offers up to five point pH calibration with automatic recognition for USA\/NIST and DIN buffers\u003c\/li\u003e\n\u003cli\u003eISE can be used infrequently or multiple times every day with advanced features such as timed end point, linear point-to-point, nonlinear selectable auto-blank and low-concentration range stability\u003c\/li\u003e\n\u003cli\u003eUser can fix errors without a complete recalibration with the calibration editing function\u003c\/li\u003e\n\u003cli\u003eNonvolatile memory holds up to 2000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eUser can easily transfer data and keep meter software up-to-date with the USB and RS232 ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A214 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-61\u003c\/span\u003e\u003c\/span\u003e (Orion™ STARA-BEA) Electrode stand\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-68\u003c\/span\u003e\u003c\/span\u003e (Orion™ 1010003) Universal power adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (Orion™ 8102BNUWP) ROSS Ultra™ Glass Refillable pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 927007MD) Stainless Steel ATC Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion™ 096019) Stirrer Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2662-42\u003c\/span\u003e\u003c\/span\u003e (Orion™ 810199 ROSS pH Buffer Kit\n\u003cul\u003e\n\u003cli\u003e1 pint (475 mL) bottle of pH 4.01 buffer \u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-910104\u003c\/span\u003e\u003c\/span\u003e (Orion™ 910104)\u003c\/li\u003e\n\u003cli\u003e1 pint (475 mL) bottle of pH 7.00 buffer \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-910107\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™\u003c\/li\u003e\n\u003cli\u003e910107)\u003c\/li\u003e\n\u003cli\u003e1 pint (475 mL) bottle of pH 10.01 buffer \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-910110\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 910110)\u003c\/li\u003e\n\u003cli\u003e1 pint (475 mL) bottle of ROSS™ pH electrode storage solution \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2668-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 810001)\u003c\/li\u003e\n\u003cli\u003e1 oz. (30 mL) bottle of general pH electrode cleaning solution \u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2673-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 900023)\u003c\/li\u003e\n\u003cli\u003eOne 12 mm diameter pH electrode storage bottle \u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2403-02\u003c\/span\u003e\u003c\/span\u003e (Orion™ 910003)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184545890619,"sku":"91-2639-14-EA","price":2830.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-14_d6c904fe-4bdc-43d0-a5a1-77b98a3c0569.png?v=1784707429"},{"product_id":"star-a214-ph-ise-mv-temperature-multiparameter-benchtop-meter-and-ammonia-ise-kit-with-stand-probes-solutions-orion-stara2146","title":"Star A214 pH\/ISE\/mV\/Temperature Multiparameter Benchtop Meter and Ammonia ISE Kit, with Stand, Probes \u0026 Solutions, Orion STARA2146","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A214 pH\/ISE Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 9512HPBNWP High-Performance Ammonia Electrode; 096019 Stirrer Probe; 951007 Ammonia 1000 ppm Standard; 951210 Low-level Ammonia ISA; 951213 Ammonia ISE Storage Solution; Electrode Arm with Holder, STARA2146\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft keys update for easy selection\u003c\/li\u003e\n\u003cli\u003eSamples can be mixed without a stir plate with direct control of the Orion™ Star™ stirrer probe \u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion 096019), sold separately\u003c\/li\u003e\n\u003cli\u003eElectrode arm and newly designed probe holder included makes it easier to maintain and place probes into samples\u003c\/li\u003e\n\u003cli\u003eMeter works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable if table space is a problem\u003c\/li\u003e\n\u003cli\u003eMultilanguage interface supports English, Spanish, French, Italian, German and Chinese\u003c\/li\u003e\n\u003cli\u003eAUTO-READ locks in the stable reading on your screen, indicator alerts user when readings are stable and timed reading gathers data in specific time intervals\u003c\/li\u003e\n\u003cli\u003eMeter offers up to five point pH calibration with automatic recognition for USA\/NIST and DIN buffers\u003c\/li\u003e\n\u003cli\u003eISE can be used infrequently or multiple times every day with advanced features such as timed end point, linear point-to-point, nonlinear selectable auto-blank and low-concentration range stability\u003c\/li\u003e\n\u003cli\u003eUser can fix errors without a complete recalibration with the calibration editing function\u003c\/li\u003e\n\u003cli\u003eNonvolatile memory holds up to 2000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eUser can easily transfer data and keep meter software up-to-date with the USB and RS232 ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A214 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-61\u003c\/span\u003e\u003c\/span\u003e (Orion™ STARA-BEA) Electrode stand\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-68\u003c\/span\u003e\u003c\/span\u003e (Orion™ 1010003) Universal power adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (Orion™ 8102BNUWP) ROSS Ultra™ Glass Refillable pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 927007MD) Stainless Steel ATC Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion™ 096019) Stirrer Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2475-20\u003c\/span\u003e\u003c\/span\u003e (Orion™ 9512HPBNWP) High-Performance Ammonia Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e21-2476-03\u003c\/span\u003e\u003c\/span\u003e (Orion™ 951007) Ammonia 1000 ppm Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e96-0077-01\u003c\/span\u003e\u003c\/span\u003e (Orion™ 951210) Low-level Ammonia ISA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2475-60\u003c\/span\u003e\u003c\/span\u003e (Orion™ 951213) Ammonia ISE Storage Solution\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184546349371,"sku":"91-2639-15-EA","price":3790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-15.png?v=1784707432"},{"product_id":"star-a214-ph-ise-benchtop-meter-kit-with-fluoride-electrode-and-solutions-ross-ultra-glass-body-ph-electrode-atc-probe-stirrer-probe-and-stand-orion-stara2147","title":"Star A214 pH\/ISE Benchtop Meter Kit with Fluoride Electrode and Solutions, ROSS Ultra Glass-Body pH Electrode, ATC Probe, Stirrer Probe and Stand, Orion, STARA2147","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ Star A214 pH\/ISE Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 9609BNWP Fluoride Electrode; 096019 Stirrer Probe; 040906 Fluoride 1 ppm with TISAB II Standard; 040907 2 ppm with TISAB II Standard; 040908 Fluoride 10 ppm with TISAB II Standard; 940909 TISAB II Solution; STARA2147\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft keys update for easy selection\u003c\/li\u003e\n\u003cli\u003eSamples can be mixed without a stir plate with direct control of the Orion™ Star™ stirrer probe \u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion 096019), sold separately\u003c\/li\u003e\n\u003cli\u003eElectrode arm and newly designed probe holder included makes it easier to maintain and place probes into samples\u003c\/li\u003e\n\u003cli\u003eMeter works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable if table space is a problem\u003c\/li\u003e\n\u003cli\u003eMultilanguage interface supports English, Spanish, French, Italian, German and Chinese\u003c\/li\u003e\n\u003cli\u003eAUTO-READ locks in the stable reading on your screen, indicator alerts user when readings are stable and timed reading gathers data in specific time intervals\u003c\/li\u003e\n\u003cli\u003eMeter offers up to five point pH calibration with automatic recognition for USA\/NIST and DIN buffers\u003c\/li\u003e\n\u003cli\u003eISE can be used infrequently or multiple times every day with advanced features such as timed end point, linear point-to-point, nonlinear selectable auto-blank and low-concentration range stability\u003c\/li\u003e\n\u003cli\u003eUser can fix errors without a complete recalibration with the calibration editing function\u003c\/li\u003e\n\u003cli\u003eNonvolatile memory holds up to 2000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eUser can easily transfer data and keep meter software up-to-date with the USB and RS232 ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A214 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-61\u003c\/span\u003e\u003c\/span\u003e (Orion™ STARA-BEA) Electrode stand\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-68\u003c\/span\u003e\u003c\/span\u003e (Orion™ 1010003) Universal power adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (Orion™ 8102BNUWP) ROSS Ultra™ Glass Refillable pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 927007MD) Stainless Steel ATC Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion™ 096019) Stirrer Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2512-22\u003c\/span\u003e\u003c\/span\u003e (Orion™ 9609BNWP) Fluoride Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e22-4510-01\u003c\/span\u003e\u003c\/span\u003e (Orion™ 040906) Fluoride 1 ppm with TISAB II Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e22-4510-02\u003c\/span\u003e\u003c\/span\u003e (Orion™ 040907) 2 ppm with TISAB II Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e22-4510-04\u003c\/span\u003e\u003c\/span\u003e (Orion™ 040908) Fluoride 10 ppm with TISAB II Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2597-15\u003c\/span\u003e\u003c\/span\u003e (Orion™ 940909) TISAB II Solution\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184546775355,"sku":"91-2639-16-EA","price":4070.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-16_e371afdc-9e8c-4119-9cf4-8d9ff4095236.png?v=1784707437"},{"product_id":"star-a214-ph-ise-benchtop-meter-kit-with-ross-sodium-electrode-and-solutions-ross-ultra-glass-body-ph-electrode-atc-probe-stirrer-probe-and-stand-orion-stara2148","title":"Star A214 pH\/ISE Benchtop Meter Kit with ROSS Sodium Electrode and Solutions, ROSS Ultra Glass-Body pH Electrode, ATC probe, Stirrer Probe and Stand, Orion, STARA2148","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A214 pH\/ISE Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 8611BNWP ROSS Sodium Electrode with Sodium Standards, Reagents and Solutions; 096019 Stirrer Probe; Electrode Arm with Redesigned Holder, STARA2148\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft keys update for easy selection\u003c\/li\u003e\n\u003cli\u003eSamples can be mixed without a stir plate with direct control of the Orion™ Star™ stirrer probe \u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion 096019), sold separately\u003c\/li\u003e\n\u003cli\u003eElectrode arm and newly designed probe holder included makes it easier to maintain and place probes into samples\u003c\/li\u003e\n\u003cli\u003eMeter works with almost every AC power source with the included universal power adapter or with four AA batteries (sold separately) to run the meter on DC power\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable if table space is a problem\u003c\/li\u003e\n\u003cli\u003eMultilanguage interface supports English, Spanish, French, Italian, German and Chinese\u003c\/li\u003e\n\u003cli\u003eAUTO-READ locks in the stable reading on your screen, indicator alerts user when readings are stable and timed reading gathers data in specific time intervals\u003c\/li\u003e\n\u003cli\u003eMeter offers up to five point pH calibration with automatic recognition for USA\/NIST and DIN buffers\u003c\/li\u003e\n\u003cli\u003eISE can be used infrequently or multiple times every day with advanced features such as timed end point, linear point-to-point, nonlinear selectable auto-blank and low-concentration range stability\u003c\/li\u003e\n\u003cli\u003eUser can fix errors without a complete recalibration with the calibration editing function\u003c\/li\u003e\n\u003cli\u003eNonvolatile memory holds up to 2000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eUser can easily transfer data and keep meter software up-to-date with the USB and RS232 ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A214 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-61\u003c\/span\u003e\u003c\/span\u003e (Orion™ STARA-BEA) Electrode stand\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e91-2639-68\u003c\/span\u003e\u003c\/span\u003e (Orion™ 1010003) Universal power adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-42\u003c\/span\u003e\u003c\/span\u003e (Orion™ 8102BNUWP) ROSS Ultra™ Glass Refillable pH Electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2646-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 927007MD) Stainless Steel ATC Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e (Orion™ 096019) Stirrer Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-56\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 8611BNWP ROSS Sodium Electrode with Sodium Standards\n\u003cul\u003e\n\u003cli\u003eOne ROSS™ sodium electrode filling solution \u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2668-23\u003c\/span\u003e\u003c\/span\u003e (Orion™ 900010): 60 mL\u003c\/li\u003e\n\u003cli\u003eOne sodium ionic strength adjustor (ISA) \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-57\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841111): 475 mL\u003c\/li\u003e\n\u003cli\u003eOne sodium known addition standard, 1000 ppm, \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-58\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841109): 475 mL\u003c\/li\u003e\n\u003cli\u003eOne 1000 ppm sodium standard with ISA \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-58\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841109): 475 mL\u003c\/li\u003e\n\u003cli\u003eOne 1000 ppm sodium standard \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-59\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841108): 475 mL\u003c\/li\u003e\n\u003cli\u003eOne Sodium reconditioning solution \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-60\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841113): 475 mL\u003c\/li\u003e\n\u003cli\u003eOne Sodium electrode storage solution \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-62\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 841101): 475 mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (purchase separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184547266875,"sku":"91-2639-17-EA","price":3510.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-17_e23b8eb5-b66e-48c4-b969-e71fdb1c6430.png?v=1784707442"},{"product_id":"star-a324-ph-ise-portable-multiparameter-meter-orion-stara3240","title":"Star A324 pH\/ISE Portable Multiparameter Meter, Orion STARA3240","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™\u003c\/strong\u003e \u003cstrong\u003eStar™ A324 pH\/ISE Multiparameter Meter, STARA3240\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH, ion concentration, mV, relative mV or ORP with temperature\u003c\/li\u003e\n\u003cli\u003eExpect high accuracy and premium performance in most demanding locations with waterproof, multiparameter meter with IP67-rated housing\u003c\/li\u003e\n\u003cli\u003eDesigned for wide range of pH, ion concentration, mV, ORP and temperature testing and field applications\u003c\/li\u003e\n\u003cli\u003ePerform up to 5 point pH calibrations with automatic buffer recognitionof NIST or DIN buffer groups with choice to manually enter custom buffer values and up to a 5 point ISE (Ion Selective Electrode) calibration with selectable units of ppm, M, mg\/L, %, ppb or none\u003c\/li\u003e\n\u003cli\u003eCalibration editing option allows individual points to be fixed without full recalibration\u003c\/li\u003e\n\u003cli\u003eLog up to 5000 data point sets with time\/date stamp with sample and user ID options and easily transfer calibration and high\/low alarm data logs via USB or RS232 to a printer or computer with free downloadable Orion Star™ Com software\u003c\/li\u003e\n\u003cli\u003eInformation-rich, easy-to-read backlit graphic display with clear onscreen instructions enables user-friendly operation\u003c\/li\u003e\n\u003cli\u003eAdvanced ISE features include non-linear selectable auto-blank and low range stability\u003c\/li\u003e\n\u003cli\u003eSupports wide variety of Orion™ ion selective electrodes including electrodes that measure ammonia, ammonium, bromide, cadmium, calcium, carbon dioxide, chloride, chlorine, cupric, cyanide, fluoride, fluoroborate, iodide, lead, nitrate, potassium, silver, sodium, sulfate, surfactant and thiocyanate concentrations\u003c\/li\u003e\n\u003cli\u003eCapture your critical readings with measurement stability indicator and selectable read modes — \u003cem\u003eAuto-Read\u003c\/em\u003e holds a stable reading, \u003cem\u003eContinuous\u003c\/em\u003e shows changing readings with hold option and \u003cem\u003eTimed\u003c\/em\u003e logs data at specific intervals\u003c\/li\u003e\n\u003cli\u003eCalibration log stores 10 most recent calibrations\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory ensures your data and settings are protected, even with loss of power\u003c\/li\u003e\n\u003cli\u003eOrion Star Com software facilitates data transfer to a computer via USB or RS232 connections\u003c\/li\u003e\n\u003cli\u003eFlexible power options with AA batteries or optional universal power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A324 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003eFour AA batteries (installed)\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide and literature CD\u003c\/li\u003e\n\u003cli\u003eUSB computer cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\t\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e5000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe (includes 8107UWMMD ROSS Ultra™ Triode pH\/ATC electrode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111036059963,"sku":"91-2639-36-EA","price":1480.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-36_56cd92c8-5381-4b2d-b129-e69e5435bcfb.png?v=1784707473"},{"product_id":"ph-ise-orion-star-a3245-portable-meter-kit-with-electrodes-and-solutions-stara3245","title":"pH\/ISE Orion Star A3245 Portable Meter Kit with Electrodes and Solutions, STARA3245","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™\u003c\/strong\u003e \u003cstrong\u003eStar™ A324 pH\/ISE Multiparameter Meter Kit, Electrode, Solutions, Armor and Case, STARA3245\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH, ion concentration, mV, relative mV or ORP with temperature\u003c\/li\u003e\n\u003cli\u003eExpect high accuracy and premium performance in most demanding locations with waterproof, multiparameter meter with IP67-rated housing\u003c\/li\u003e\n\u003cli\u003eDesigned for wide range of pH, ion concentration, mV, ORP and temperature testing and field applications\u003c\/li\u003e\n\u003cli\u003ePerform up to 5 point pH calibrations with automatic buffer recognitionof NIST or DIN buffer groups with choice to manually enter custom buffer values and up to a 5 point ISE (Ion Selective Electrode) calibration with selectable units of ppm, M, mg\/L, %, ppb or none\u003c\/li\u003e\n\u003cli\u003eCalibration editing option allows individual points to be fixed without full recalibration\u003c\/li\u003e\n\u003cli\u003eLog up to 5000 data point sets with time\/date stamp with sample and user ID options and easily transfer calibration and high\/low alarm data logs via USB or RS232 to a printer or computer with free downloadable Orion Star™ Com software\u003c\/li\u003e\n\u003cli\u003eInformation-rich, easy-to-read backlit graphic display with clear onscreen instructions enables user-friendly operation\u003c\/li\u003e\n\u003cli\u003eAdvanced ISE features include non-linear selectable auto-blank and low range stability\u003c\/li\u003e\n\u003cli\u003eSupports wide variety of Orion™ ion selective electrodes including electrodes that measure ammonia, ammonium, bromide, cadmium, calcium, carbon dioxide, chloride, chlorine, cupric, cyanide, fluoride, fluoroborate, iodide, lead, nitrate, potassium, silver, sodium, sulfate, surfactant and thiocyanate concentrations\u003c\/li\u003e\n\u003cli\u003eCapture your critical readings with measurement stability indicator and selectable read modes — \u003cem\u003eAuto-Read\u003c\/em\u003e holds a stable reading, \u003cem\u003eContinuous\u003c\/em\u003e shows changing readings with hold option and \u003cem\u003eTimed\u003c\/em\u003e logs data at specific intervals\u003c\/li\u003e\n\u003cli\u003eCalibration log stores 10 most recent calibrations\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory ensures your data and settings are protected, even with loss of power\u003c\/li\u003e\n\u003cli\u003eOrion Star Com software facilitates data transfer to a computer via USB or RS232 connections\u003c\/li\u003e\n\u003cli\u003eFlexible power options with AA batteries or optional universal power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A324 pH\/ISE meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-53\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 8107UWMMD) Ultra Triode gel-filled epoxy-body pH\/ATC electrode, 3 m cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-04\u003c\/span\u003e \u003c\/span\u003e(Orion 910410-WA) pH 4.01 Buffer pouches, 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 910710) pH 7.00 Buffer pouches, 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-10\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 911010) pH 10.01 Buffer pouches, 10\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e 91-2668-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion 810001) ROSS electrode storage solution\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-21\u003c\/span\u003e\u003c\/span\u003e (Orion 911110) Electrode rinse solution pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2639-63\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion STARA-AR) Protective armor with electrode holder and storage sleeve\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e 91-2639-60\u003c\/span\u003e\u003c\/span\u003e (STARA-CS)Hard-sided field case\u003c\/li\u003e\n\u003cli\u003eFour AA batteries (installed)\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide and literature CD\u003c\/li\u003e\n\u003cli\u003eUSB computer cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\t\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e5000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe (includes 8107UWMMD ROSS Ultra™ Triode pH\/ATC electrode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184551985467,"sku":"91-2639-37-EA","price":2110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-37_0fe0d969-bd73-444a-8fd8-b3029547e429.png?v=1784707478"},{"product_id":"orion-versa-star-benchtop-meter-with-ph-ise-mv-orp-and-temperature-module-stand-thermo-scientific-vstar40a","title":"Orion Versa Star Benchtop Meter with pH, ISE, mV, ORP and Temperature Module\/Stand, Thermo Scientific, VSTAR40A","description":"\u003cp\u003e\u003cstrong\u003eOrion™ Versa Star™ Benchtop Meter with pH\/ISE\/mV\/ORP\/Temperature module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eGet high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE Module. Meet your most challenging applications for pH, ion concentration, mV, ORP and temperature. Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules. Perform up to six point pH and ISE calibrations, log up to 2000 data point sets with time\/date stamp and transfer calibration and data logs via USB or RS232 to a printer or computer. Select systems with one or two pH\/ISE modules.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/li\u003e\n\u003cli\u003eVSTAR-ISE pH\/ISE\/Temperature Module\u003c\/li\u003e\n\u003cli\u003eElectrode Stand\u003c\/li\u003e\n\u003cli\u003eUniversal Power Adapter\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted Quick Start Guide\u003c\/li\u003e\n\u003cli\u003eComputer Interface Cable\u003c\/li\u003e\n\u003cli\u003eMeter Test Certificate\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111036879163,"sku":"91-2639-87-EA","price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-87_4ace7d33-8ca4-4771-9765-21c789cae880.png?v=1784707541"},{"product_id":"orion-versa-star-benchtop-meter-with-ph-ise-mv-orp-and-temperature-module-ross-ultra-glass-ph-electrode-stainless-steel-atc-probe-stirrer-probe-solutions-stand-thermo-scientific-vstar40a2","title":"Orion Versa Star Benchtop Meter with pH, ISE, mV, ORP and Temperature Module\/ROSS Ultra Glass pH Electrode\/Stainless Steel ATC Probe\/Stirrer Probe\/Solutions\/Stand, Thermo Scientific, VSTAR40A2","description":"\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star™ Benchtop Meter with pH\/ISE\/mV\/ORP\/Temperature module\/ROSS® Ultra® Glass-body pH electrode\/ATC probe\/Stirrer Probe\/Solutions\/Stand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE Module.  Meet your most challenging applications for pH, ion concentration, mV, ORP and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Perform up to six point pH and ISE calibrations, log up to 2000 data point sets with time\/date stamp and transfer calibration and data logs via USB or RS232 to a printer or computer.  Select systmes with one or two pH\/ISE modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-ISE pH\/ISE\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e8102BNUWP ROSS® Ultra® glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e927007MD Orion\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e™ Stainless Steel ATC probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e096019 \u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eOrion\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e™\u003c\/span\u003e\u003c\/span\u003e Star\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e® Stirrer probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e810199 ROSS\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e®\u003c\/span\u003e pH buffer and Solution Kit\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111036911931,"sku":"91-2639-88-EA","price":3560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-88.png?v=1784707546"},{"product_id":"ph-ise-meter-versa-star-40b-with-2-ph-ise-temp-modules-and-electrode-holder-thermo-scientific-vstar40b","title":"pH\/ISE Meter, Versa Star 40B with 2 pH\/ISE\/Temp Modules and Electrode Holder, Thermo Scientific, VSTAR40B","description":"\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star™ Benchtop Meter with two pH\/ISE\/mV\/ORP\/Temperature modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE Module.  Meet your most challenging applications for pH, ion concentration, mV, ORP and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Perform up to six point pH and ISE calibrations, log up to 2000 data point sets with time\/date stamp and transfer calibration and data logs via USB or RS232 to a printer or computer.  Select systmes with one or two pH\/ISE modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e2 VSTAR-ISE pH\/ISE\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111036944699,"sku":"91-2639-89-EA","price":3350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-89.png?v=1784707550"},{"product_id":"ph-ise-meter-versa-star-40b-kit-with-2-ph-ise-modules-ross-ultra-ph-electrode-atc-probe-stirrer-probe-2-stands-and-solutions-thermo-scientific-vstar40b2","title":"pH\/ISE Meter, Versa Star 40B Kit with 2 pH\/ISE Modules, ROSS Ultra pH Electrode, ATC Probe,Stirrer Probe, 2 Stands and Solutions, Thermo Scientific, VSTAR40B2","description":"\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star™ Benchtop Meter with two pH\/ISE\/mV\/ORP\/Temperature modules\/ROSS® Ultra® Glass-Body pH Electrode\/ATC Probe\/Stirrer Probe\/Solutions\/two Stands\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE Module.  Meet your most challenging applications for pH, ion concentration, mV, ORP and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Perform up to six point pH and ISE calibrations, log up to 2000 data point sets with time\/date stamp and transfer calibration and data logs via USB or RS232 to a printer or computer.  Select systmes with one or two pH\/ISE modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e2 VSTAR-ISE pH\/ISE\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e8102BNUWP \u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eROSS® Ultra® Glass-Body pH Electrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e927007MD Orion™ Stainless Steel ATC Probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e096019 Orion\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e™\u003c\/span\u003e\u003c\/span\u003e Star® Stirrer Probe\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e810199 ROSS\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e® pH Buffer and Solution Kit \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e2 Electrode Stands\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111036977467,"sku":"91-2639-90-EA","price":4120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-90.png?v=1784707555"},{"product_id":"ph-ise-meter-versa-star-90-with-ph-ise-temp-conductivity-do-modules-thermo-scientific-vstar90","title":"pH\/ISE Meter, Versa Star 90 with pH\/ISE\/Temp, Conductivity \u0026 DO Modules, Thermo Scientific, VSTAR90","description":"\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star Benchtop Meter with pH\/ISE\/mV Module, Conductivity\/TDS\/Salinity\/Resistivity Module and RDO\/Dissolved Oxygen Module\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy.premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE, Conductivity and Dissolved Oxygen\/RDO Modules.  Meet your most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Log up to 2000 data point sets with time\/date stamp and easily transfer logs via USB or RS232 to a printer or computer.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-ISE pH\/ISE\/mV\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-CND Conductivity\/TDS\/Salinity\/Resistivity\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-RD RDO\/DO Module\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111037436219,"sku":"91-2639-95-EA","price":4360.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-95.png?v=1784707577"},{"product_id":"ph-ise-meter-versa-star-92-with-ph-ise-temp-conductivity-do-modules-probes-thermo-scientific-vstar92","title":"pH\/ISE Meter, Versa Star 92 with pH\/ISE\/Temp, Conductivity \u0026 DO Modules \u0026 Probes, Thermo Scientific, VSTAR92","description":"\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star Benchtop Meter with pH\/ISE\/mV Module, Conductivity\/TDS\/Salinity\/Resistivity Module and RDO\/Dissolved Oxygen Module plus ROSS® Ultra® Triode pH\/ATC probe, Orion™ DuraProbe Conductivity Cell, and Orion™ polarographic DO probe, Solutions, and Stand\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy.premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE, Conductivity and Dissolved Oxygen\/RDO Modules.  Meet your most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Log up to 2000 data point sets with time\/date stamp and easily transfer logs via USB or RS232 to a printer or computer.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-ISE pH\/ISE\/mV\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-CND Conductivity\/TDS\/Salinity\/Resistivity\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-RD RDO\/DO Module\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e8157BNUMD ROSS® Ultra® Triode pH\/ATC probe\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e013005MD Orion™ DuraProbe Conductivity Cell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e083005MD Orion™ polarographic DO probe with calibration sleeve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e096019 Orion™ Star® Stirrer Probe\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e080513 DO Probe Maintenance Kit\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eBOD adapter, Funnel, and Stirrer\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e810199 ROSS pH buffer and Solution Kit (475 mL each pH 4, 7, \u0026amp; 10 Buffers, and Storage Solution, 60 mL Electrode cleaning Solution, and 12mm pH electrode storage bottle)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e011007 Orion™ 1413 μS Conductivity Standard\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111037468987,"sku":"91-2639-96-EA","price":5270.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-96_b30bcb55-e547-4412-95f2-2d93c7af1117.png?v=1784707582"},{"product_id":"ph-ise-meter-versa-star-91-with-2-ph-ise-temp-conductivity-do-modules-thermo-scientific-vstar91","title":"pH\/ISE Meter, Versa Star 91 with 2 pH\/ISE\/Temp, Conductivity \u0026 DO Modules, Thermo Scientific, VSTAR91","description":"\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star Benchtop Meter with two pH\/ISE Modules, Conductivity\/TDS\/Salinity\/Resistivity Module and RDO\/Dissolved Oxygen Module\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy.premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE, Conductivity and Dissolved Oxygen\/RDO Modules.  Meet your most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Log up to 2000 data point sets with time\/date stamp and easily transfer logs via USB or RS232 to a printer or computer.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e2 VSTAR-ISE pH\/ISE\/mV\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-CND Conductivity\/TDS\/Salinity\/Resistivity\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-RD RDO\/DO Module\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111037501755,"sku":"91-2639-97-EA","price":5780.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-97_7bb50db1-dfb1-4b42-af5b-1f13c53cbea0.png?v=1784707587"},{"product_id":"ph-ise-meter-versa-star-93-with-2-ph-ise-temp-conductivity-do-modules-probes-thermo-scientific-vstar93","title":"pH\/ISE Meter, Versa Star 93 with 2 pH\/ISE\/Temp, Conductivity \u0026 DO Modules \u0026 Probes, Thermo Scientific, VSTAR93","description":"\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: Arial,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: bold; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eOrion™ Versa Star Benchtop Meter with two pH\/ISE\/mV Modules, Conductivity\/TDS\/Salinity\/Resistivity Module and RDO\/Dissolved Oxygen Module plus ROSS® Ultra® Triode pH\/ATC probe, Orion™ DuraProbe Conductivity Cell, and Orion™ polarographic DO probe, Solutions, and Stand\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGet high accuracy.premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Benchtop Meter with pH\/ISE, Conductivity and Dissolved Oxygen\/RDO Modules.  Meet your most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature.  Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules.  Log up to 2000 data point sets with time\/date stamp and easily transfer logs via USB or RS232 to a printer or computer.\u003c\/span\u003e\u003c\/span\u003e\u003cstrong style=\"color: #000000; font-family: Arial,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: bold; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: Arial,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: bold; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eIncludes:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVersa Star\u003cstrong\u003e™\u003c\/strong\u003e Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e2 VSTAR-ISE pH\/ISE\/mV\/Temperature Modules\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-CND Conductivity\/TDS\/Salinity\/Resistivity\/Temperature Module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eVSTAR-RD RDO\/DO Module\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e8157BNUMD ROSS® Ultra® Triode pH\/ATC probe\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e013005MD Orion™ DuraProbe Conductivity Cell\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e083005MD Orion™ polarographic DO probe with calibration sleeve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e096019 Orion™ Star® Stirrer Probe\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e080513 DO Probe Maintenance Kit\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eBOD adapter, Funnel, and Stirrer\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e810199 ROSS pH buffer and Solution Kit (475 mL each pH 4, 7, \u0026amp; 10 Buffers, and Storage Solution, 60 mL Electrode cleaning Solution, and 12mm pH electrode storage bottle)\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e011007 Orion™ 1413 μS Conductivity Standard\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eElectrode Stand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUniversal Power Adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eLiterature CD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ePrinted Quick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eComputer Interface Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMeter Test Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: Arial,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: bold; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e\u003cspan style=\"font-size: small;\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111037534523,"sku":"91-2639-98-EA","price":7710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-98.png?v=1784707591"},{"product_id":"orion-pro-star-pi214-ph-ion-bench-meter-only-with-stand-thermo-scientific-pstar2140","title":"Orion Pro Star PI214 pH\/Ion Bench Meter Only with Stand, Thermo Scientific, PSTAR2140","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star PI214 pH\/Ion Bench Meter Only with Stand, PSTAR2140\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH, mV, ORP or ion concentration with temperature\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRead types\u003c\/td\u003e \u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eBNC, 8-pin MiniDin (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PI214 pH\/ion bench meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111038091579,"sku":"91-2640-29-EA","price":1630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-29_2d419e92-0e67-4ee8-ad11-f5a85407372f.png?v=1784707644"},{"product_id":"orion-pro-star-pi214-ph-ion-bench-meter-ph-kit-thermo-scientific-pstar2145","title":"Orion Pro Star PI214 pH\/Ion Bench Meter pH Kit, Thermo Scientific, PSTAR2145","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star PI214 pH\/Ion Bench Meter pH Kit, PSTAR2145\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH, mV, ORP or ion concentration with temperature\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRead types\u003c\/td\u003e \u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eBNC, 8-pin MiniDin (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PI214 pH\/ion bench meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eRefillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers\u003c\/li\u003e\n\u003cli\u003eRinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111038124347,"sku":"91-2640-30-EA","price":2260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-30_2932db8a-cf15-4638-b353-a298ed52b263.png?v=1784707647"},{"product_id":"orion-pro-star-pi214-ph-ion-bench-meter-ammonia-kit-thermo-scientific-pstar2146","title":"Orion Pro Star PI214 pH\/Ion Bench Meter Ammonia Kit, Thermo Scientific, PSTAR2146","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star PI214 pH\/Ion Bench Meter Ammonia Kit with Stand, PSTAR2146\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"border-collapse:\" collapse border=\"1\" width:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH, mV, ORP or ion concentration with temperature\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRead types\u003c\/td\u003e \u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eBNC, 8-pin MiniDin (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PI214 pH\/ion bench meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eHigh-performance ammonia ion selective electrode (9512HPBNWP)\u003c\/li\u003e\n\u003cli\u003eStainless steel ATC temperature probe (927007MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003eAmmonia 1000 ppm standard\u003c\/li\u003e\n\u003cli\u003eAmmonia ISA\u003c\/li\u003e\n\u003cli\u003eAmmonia electrode storage solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111038157115,"sku":"91-2640-31-EA","price":2540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-31.png?v=1784707650"},{"product_id":"orion-pro-star-pi214-ph-ion-bench-meter-fluoride-kit-thermo-scientific-pstar2147","title":"Orion Pro Star PI214 pH\/Ion Bench Meter Fluoride Kit, Thermo Scientific, PSTAR2147","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star PI214 pH\/Ion Bench Meter Fluoride Kit with Stand, PSTAR2147\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"border-collapse:\" collapse border=\"1\" width:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH, mV, ORP or ion concentration with temperature\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRead types\u003c\/td\u003e \u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eBNC, 8-pin MiniDin (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PI214 pH\/ion bench meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eFluoride ion selective electrode (9609BNWP)\u003c\/li\u003e\n\u003cli\u003eStainless steel ATC temperature probe (927007MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003eFluoride 100 ppm standard\u003c\/li\u003e\n\u003cli\u003eFluoride 0.5, 1 and 5 ppm standards premixed with TISAB II\u003c\/li\u003e\n\u003cli\u003eTISAB II solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111038353723,"sku":"91-2640-32-EA","price":2590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-32.png?v=1784707653"},{"product_id":"orion-pro-star-pi214-ph-ion-bench-meter-sodium-kit-thermo-scientific-pstar2148","title":"Orion Pro Star PI214 pH\/Ion Bench Meter Sodium Kit, Thermo Scientific, PSTAR2148","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star PI214 pH\/Ion Bench Meter Sodium Kit with Stand, PSTAR2148\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"border-collapse:\" collapse border=\"1\" width:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH, mV, ORP or ion concentration with temperature\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRead types\u003c\/td\u003e \u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eBNC, 8-pin MiniDin (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PI214 pH\/ion bench meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eROSS sodium ion selective electrode (8611BNWP)\u003c\/li\u003e\n\u003cli\u003eStainless steel ATC temperature probe (927007MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003eSodium 1000 ppm standard\u003c\/li\u003e\n\u003cli\u003eSodium ISA\u003c\/li\u003e\n\u003cli\u003eSodium electrode conditioning solution\u003c\/li\u003e\n\u003cli\u003eSodium electrode storage solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111038386491,"sku":"91-2640-33-EA","price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-33.png?v=1784707656"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-only-with-stand-thermo-scientific-pstar2170","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter Only with Stand, Thermo Scientific, PSTAR2170","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter Only with Stand, PSTAR2170\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039172923,"sku":"91-2640-55-EA","price":2490.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-55_bc967af6-37be-45c9-a2aa-233f1f8ebcd5.png?v=1784707681"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-standard-ph-kit-thermo-scientific-pstar2175","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter Standard pH Kit, Thermo Scientific, PSTAR2175","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter Standard pH Kit with Stand, PSTAR2175\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable glass-body pH\/ATC electrode (8302BNUMD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers\u003c\/li\u003e\n\u003cli\u003eRinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039205691,"sku":"91-2640-56-EA","price":3120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-56_ca88f8f5-5689-4086-b6b4-a3e8b2e614c7.png?v=1784707684"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-durable-ph-kit-thermo-scientific-pstar2176","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter Durable pH Kit, Thermo Scientific, PSTAR2176","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter Durable pH Kit with Stand, PSTAR2176\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers\u003c\/li\u003e\n\u003cli\u003eRinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039402299,"sku":"91-2640-57-EA","price":3120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-57_6aba18e7-8b39-49ef-a858-86b451480221.png?v=1784707688"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-ph-and-ammonia-kit-thermo-scientific-pstar2177","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter pH and Ammonia Kit, Thermo Scientific, PSTAR2177","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter pH and Ammonia Kit with Stand, PSTAR2177\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003eAmmonia ion selective electrode (9512BNWP)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers\u003c\/li\u003e\n\u003cli\u003eRinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003eAmmonia 1000 ppm standard\u003c\/li\u003e\n\u003cli\u003eAmmonia ISA\u003c\/li\u003e\n\u003cli\u003eAmmonia electrode storage solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039467835,"sku":"91-2640-58-EA","price":3800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-58_e796dfcb-7819-47aa-a073-594a7c92af4d.png?v=1784707691"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-ph-and-fluoride-kit-thermo-scientific-pstar2178","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter pH and Fluoride Kit, Thermo Scientific, PSTAR2178","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter pH and Fluoride Kit with Stand, PSTAR2178\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003eFluoride ion selective electrode (9609BNWP)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers and rinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003eFluoride 100 ppm standard\u003c\/li\u003e\n\u003cli\u003eFluoride 0.5, 1 and 5 ppm standards premixed with TISAB II\u003c\/li\u003e\n\u003cli\u003eTISAB II solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039500603,"sku":"91-2640-59-EA","price":3900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-59_6dacdac6-8e7c-402c-b9a9-56978058c982.png?v=1784707695"},{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-ph-and-sodium-kit-thermo-scientific-pstar2179","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter pH and Sodium Kit, Thermo Scientific, PSTAR2179","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter Only with Stand, PSTAR2170\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039566139,"sku":"91-2640-60-EA","price":3800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-60_b09bca8d-4000-4faf-a414-4a7283488ea3.png?v=1784707698"},{"product_id":"orion-pro-star-mp218-multiparameter-meter-ph-ion-conductivity-and-do-bench-meter-only-with-stand-thermo-scientific-pstar2180","title":"Orion Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter Only with Stand, Thermo Scientific, PSTAR2180","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter Only with Stand, PSTAR2180\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 microS\/cm to 3000 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 microS\/cm minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e100.0 microS\/cm, 1413 microS\/cm, 12.88 mS\/cm, 111.9 mS\/cm or up to 4 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.100 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.475 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.550 cm\u003csup\u003e-1\u003c\/sup\u003e, 1.000 cm\u003csup\u003e-1\u003c\/sup\u003e, 10.00 cm\u003csup\u003e-1\u003c\/sup\u003e or user-defined from 0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear (0.00 to 10.00 %\/ degrees C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP\/USP or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25 or 30 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg\/L to 500.0 g\/L (TDS factor of 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm or mg\/L minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppm to ppt; or mg\/L to g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003eLinear (0.01 to 10.00), ISO\/EN 27888, 442, NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eNatural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 ohms to 100.0 Mohs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ohms minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0% saturation; 0.01 to 90.0 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 1% saturation; 0.01, 0.1 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2% saturation; +\/-0.02 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Types\u003c\/td\u003e\n\u003ctd\u003eWater-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or\u0026gt;custom value (Winkler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Correction Range\u003c\/td\u003e\n\u003ctd\u003e400.0 to 850.0 mm Hg; or 0.533 to 1.133 bar; automatic with built-in barometer or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-6.0 mmHg; or 0.008 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Type\u003c\/td\u003e\n\u003ctd\u003ePolarographic or optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: conductivity, TDS, salinity or resistivity with temperature; Channel 3: dissolved oxygen as % saturation or concentration (mg\/L or ppm) with barometric pressure and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (30 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: 8-pin MiniDIN; Channel 3: 9-pin MiniDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039598907,"sku":"91-2640-66-EA","price":2730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-66_0ee445f1-6425-46ea-8b76-e15a8d334051.png?v=1784707701"},{"product_id":"orion-pro-star-mp218-multiparameter-meter-ph-ion-conductivity-and-do-bench-meter-ph-conductivity-and-do-kit-thermo-scientific-pstar2185","title":"Orion Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter pH, Conductivity and DO Kit, Thermo Scientific, PSTAR2185","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter Kit with Stand, PSTAR2185\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 microS\/cm to 3000 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 microS\/cm minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e100.0 microS\/cm, 1413 microS\/cm, 12.88 mS\/cm, 111.9 mS\/cm or up to 4 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.100 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.475 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.550 cm\u003csup\u003e-1\u003c\/sup\u003e, 1.000 cm\u003csup\u003e-1\u003c\/sup\u003e, 10.00 cm\u003csup\u003e-1\u003c\/sup\u003e or user-defined from 0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear (0.00 to 10.00 %\/ degrees C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP\/USP or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25 or 30 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg\/L to 500.0 g\/L (TDS factor of 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm or mg\/L minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppm to ppt; or mg\/L to g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003eLinear (0.01 to 10.00), ISO\/EN 27888, 442, NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eNatural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 ohms to 100.0 Mohs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ohms minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0% saturation; 0.01 to 90.0 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 1% saturation; 0.01, 0.1 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2% saturation; +\/-0.02 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Types\u003c\/td\u003e\n\u003ctd\u003eWater-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or\u0026gt;custom value (Winkler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Correction Range\u003c\/td\u003e\n\u003ctd\u003e400.0 to 850.0 mm Hg; or 0.533 to 1.133 bar; automatic with built-in barometer or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-6.0 mmHg; or 0.008 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Type\u003c\/td\u003e\n\u003ctd\u003ePolarographic or optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: conductivity, TDS, salinity or resistivity with temperature; Channel 3: dissolved oxygen as % saturation or concentration (mg\/L or ppm) with barometric pressure and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (30 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: 8-pin MiniDIN; Channel 3: 9-pin MiniDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003e4-cell epoxy\/graphite-body K=0.475 conductivity\/ATC electrode (013005MD)\u003c\/li\u003e\n\u003cli\u003ePolarographic DO\/ATC electrode with calibration sleeve (083005MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers\u003c\/li\u003e\n\u003cli\u003eRinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003e1413 μS\/cm conductivity standard pouches\u003c\/li\u003e\n\u003cli\u003ePolarographic DO electrode maintenance kit\u003c\/li\u003e\n\u003cli\u003eBOD adapter\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039697211,"sku":"91-2640-67-EA","price":4720.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-67.png?v=1784707704"},{"product_id":"orion-pro-star-mp218-multiparameter-meter-ph-ion-conductivity-and-do-bench-meter-ph-conductivity-and-optical-do-kit-thermo-scientific-pstar2186","title":"Orion Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter pH, Conductivity and Optical DO Kit, Thermo Scientific, PSTAR2186","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter Optical DO Kit with Stand, PSTAR2186\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 microS\/cm to 3000 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 microS\/cm minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e100.0 microS\/cm, 1413 microS\/cm, 12.88 mS\/cm, 111.9 mS\/cm or up to 4 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.100 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.475 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.550 cm\u003csup\u003e-1\u003c\/sup\u003e, 1.000 cm\u003csup\u003e-1\u003c\/sup\u003e, 10.00 cm\u003csup\u003e-1\u003c\/sup\u003e or user-defined from 0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear (0.00 to 10.00 %\/ degrees C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP\/USP or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25 or 30 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg\/L to 500.0 g\/L (TDS factor of 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm or mg\/L minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppm to ppt; or mg\/L to g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003eLinear (0.01 to 10.00), ISO\/EN 27888, 442, NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eNatural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 ohms to 100.0 Mohs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ohms minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0% saturation; 0.01 to 90.0 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 1% saturation; 0.01, 0.1 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2% saturation; +\/-0.02 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Types\u003c\/td\u003e\n\u003ctd\u003eWater-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or\u0026gt;custom value (Winkler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Correction Range\u003c\/td\u003e\n\u003ctd\u003e400.0 to 850.0 mm Hg; or 0.533 to 1.133 bar; automatic with built-in barometer or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-6.0 mmHg; or 0.008 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Type\u003c\/td\u003e\n\u003ctd\u003ePolarographic or optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: conductivity, TDS, salinity or resistivity with temperature; Channel 3: dissolved oxygen as % saturation or concentration (mg\/L or ppm) with barometric pressure and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (30 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: 8-pin MiniDIN; Channel 3: 9-pin MiniDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003e4-cell epoxy\/graphite-body K=0.475 conductivity\/ATC electrode (013005MD)\u003c\/li\u003e\n\u003cli\u003eOptical DO\/ATC electrode with calibration sleeve, guard and optical cap (087010MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers and rinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003e1413 μS\/cm conductivity standard pouches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039729979,"sku":"91-2640-68-EA","price":4830.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-68_ee42b93b-a918-4174-adcd-63d56f667fa6.png?v=1784707707"},{"product_id":"orion-pro-star-mp218-multiparameter-meter-ph-ion-conductivity-and-do-bench-meter-ph-and-conductivity-kit-thermo-scientific-pstar2187","title":"Orion Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter pH and Conductivity Kit, Thermo Scientific, PSTAR2187","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter pH and Conductivity Kit with Stand, PSTAR2187\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 microS\/cm to 3000 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 microS\/cm minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e100.0 microS\/cm, 1413 microS\/cm, 12.88 mS\/cm, 111.9 mS\/cm or up to 4 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.100 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.475 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.550 cm\u003csup\u003e-1\u003c\/sup\u003e, 1.000 cm\u003csup\u003e-1\u003c\/sup\u003e, 10.00 cm\u003csup\u003e-1\u003c\/sup\u003e or user-defined from 0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear (0.00 to 10.00 %\/ degrees C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP\/USP or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25 or 30 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg\/L to 500.0 g\/L (TDS factor of 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm or mg\/L minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppm to ppt; or mg\/L to g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003eLinear (0.01 to 10.00), ISO\/EN 27888, 442, NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eNatural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 ohms to 100.0 Mohs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ohms minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eDissolved Oxygen\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0% saturation; 0.01 to 90.0 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 1% saturation; 0.01, 0.1 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-2% saturation; +\/-0.02 mg\/L or ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Types\u003c\/td\u003e\n\u003ctd\u003eWater-saturated air (100% and 0% saturation), air-saturated water (100% and 0% saturation) or\u0026gt;custom value (Winkler)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Correction Range\u003c\/td\u003e\n\u003ctd\u003e400.0 to 850.0 mm Hg; or 0.533 to 1.133 bar; automatic with built-in barometer or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Relative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-6.0 mmHg; or 0.008 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometer Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Correction\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Type\u003c\/td\u003e\n\u003ctd\u003ePolarographic or optical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: conductivity, TDS, salinity or resistivity with temperature; Channel 3: dissolved oxygen as % saturation or concentration (mg\/L or ppm) with barometric pressure and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (30 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: 8-pin MiniDIN; Channel 3: 9-pin MiniDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preser data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star MP218 Multiparameter Meter, pH\/Ion, Conductivity and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003e4-cell epoxy\/graphite-body K=0.475 conductivity\/ATC electrode (013005MD)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers and rinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003e1413 μS\/cm conductivity standard pouches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039762747,"sku":"91-2640-69-EA","price":3910.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-69.png?v=1784707711"},{"product_id":"orion-dual-star-ph-ise-orp-benchtop-meter-with-8102bnuwp-ross-ultra-electrode-and-ss-atc-probe-orion-2115101","title":"Orion Dual Star pH\/ISE\/ORP Benchtop Meter with 8102BNUWP ROSS Ultra Electrode and SS ATC Probe, Orion 2115101","description":"\u003cdiv\u003e \u003c\/div\u003e\u003cspan style=\"\" times new roman font-family:=\"\" font-size:=\"\"\u003e  \u003cdiv\u003eThe Orion DUAL STAR\u003cspan style=\"\" font-family: times new roman font-size:\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003emeter makes it easy to do two things at once.\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/span\u003e\u003cdiv\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003e \u003c\/span\u003e\u003c\/div\u003e\u003cspan style=\"\" times new roman font-family:=\"\" font-size:=\"\"\u003e  \u003cp align=\"\" left\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eDual channel with simultaneously displayed measurements\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eLow concentration range reading stability\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eKnown addition and subtraction incremental methods\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003e5 language choices: English, Spanish, French, German and Italian\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eMeter prompts and shortcut keys\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eThermo Scientific Orion EZ Startup for quick and easy meter set up\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eE\u003cspan style=\"\" font-family: times new roman font-size:\u003e\u003cspan style=\"\" font-size:\u003eH\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003eORP calibration capability\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: times new roman font-size:\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003e10 methods stored per channel  retains calibrations among multiple electrodes           \u003cli\u003e            \u003cdiv align=\"\" left\u003e1000 point datalogging with time and date stamping\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eCalibration, high point and low point alarms\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eCalibration graph with slope data for on-screen viewing\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eStar stirrer probe controlled directly from the meter\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eAutosampler compatibility\u003c\/div\u003e\n\u003c\/li\u003e          \u003cp align=\"\" left\u003e \u003c\/p\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003epH\u003c\/strong\u003e \u003c\/p\u003e\u003c\/span\u003e          \u003cul\u003e            \u003cli\u003e              \u003cdiv align=\"\" left\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange - 2.000 to 19.999                   \u003cli\u003e                    \u003cdiv align=\"\" left\u003eResolution 0.1, 0.01, 0.001\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eRelative Accuracy  0.002\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Points 1 to 6\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eAuto-Buffer Recognition  \u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eUSA\/NIST and EURO\/DIN\u003c\/div\u003e\n\u003c\/li\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e          \u003c\/ul\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003eISE\u003c\/strong\u003e \u003c\/p\u003e\u003c\/span\u003e          \u003cul\u003e            \u003cli\u003e              \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange 0 to 19999                   \u003cli\u003e                    \u003cdiv align=\"\" left\u003eResolution 1, 2 or 3 significant digits\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eRelative Accuracy  0.2 mV or 0.05 %, whichever is greater\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eUnits ppm, ppb, M, % or unitless\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eTechnique Options    Single known addition and subtraction Double known addition and subtraction\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Points 2 to 6\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Options Linear, point to point, non-linear selectable auto-blank \u003c\/div\u003e\n\u003c\/li\u003e                  \u003cp align=\"\" left\u003e\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e\u003cstrong\u003emV\/Rel mV\/ORP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e                  \u003cul\u003e                    \u003cli\u003e                      \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange  1999.9                           \u003cli\u003e                            \u003cdiv align=\"\" left\u003eResolution 0.1\u003c\/div\u003e\n\u003c\/li\u003e                          \u003cli\u003e                            \u003cdiv align=\"\" left\u003eRelative Accuracy  0.2 mV or 0.05 %, whichever is greater\u003c\/div\u003e\n\u003c\/li\u003e                          \u003cli\u003e                            \u003cdiv align=\"\" left\u003eE\u003cspan style=\"\" font-family: universltstd-light font-size:\u003e\u003cspan style=\"\" font-size:\u003eH\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eCalibration Capability  Yes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e                  \u003c\/ul\u003e                  \u003cp\u003e \u003c\/p\u003e\u003c\/span\u003e            \u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e  \u003cp align=\"\" left\u003e\u003cstrong\u003eTemperature \u003c\/strong\u003e\u003c\/p\u003e\u003c\/span\u003e\u003cul\u003e  \u003cli\u003e    \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange - 5 to 105 C         \u003cli\u003e          \u003cdiv align=\"\" left\u003eResolution 0.1 C\u003c\/div\u003e\n\u003c\/li\u003e        \u003cli\u003e          \u003cdiv align=\"\" left\u003eRelative Accuracy  0.1 C\u003c\/div\u003e\n\u003c\/li\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e\u003c\/span\u003e\u003cdiv align=\"\" left\u003e \u003c\/div\u003e\n\u003cdiv align=\"\" left\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041171771,"sku":"91-2654-20-EA","price":3030.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-20_414aead2-91da-497a-992c-6ec5e17fd9eb.png?v=1784707760"},{"product_id":"dual-star-meter-with-electrode-stand-universal-power-adapter-8157bnumd-ross-ultra-epoxy-refillable-ph-atc-triode-electrode","title":"Dual STAR Meter with Electrode Stand; Universal Power Adapter; 8157BNUMD ROSS Ultra Epoxy Refillable pH\/ATC Triode Electrode","description":"\u003cp\u003eSPECIFICATIONS\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy (ISE) ±0.2 mV or ±0.05 of reading, whichever is greater\u003c\/li\u003e\n\u003cli\u003eAccuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater\u003c\/li\u003e\n\u003cli\u003eAccuracy (pH) ±0.002pH Data Points 1000\u003c\/li\u003e\n\u003cli\u003eDescription Orion DUAL STAR pH\/mV\/ISE\/Temperature Dual Channel Benchtop Meter Kit\u003c\/li\u003e\n\u003cli\u003eDisplay Type Graphic LCD with backlight\u003c\/li\u003e\n\u003cli\u003eInputs 2 BNC (pH or ISE), 2 x 8-pin Mini-DIN (temperature), 2 reference pin-tip, stirrer input\u003c\/li\u003e\n\u003cli\u003eOutputs USB, RS232\u003c\/li\u003e\n\u003cli\u003ePower Supply Universal 90-260 VAC (included)\u003c\/li\u003e\n\u003cli\u003eRange (ISE) 0 to 19999 in ppm, M, %, ppb or unitless\u003c\/li\u003e\n\u003cli\u003eRange (mV) ±1999.9mV\u003c\/li\u003e\n\u003cli\u003eRange (pH) -2.000 to 19.999pH\u003c\/li\u003e\n\n\u003cli\u003eResolution (ISE) Up to 3 significant digits\u003c\/li\u003e\n\u003cli\u003eResolution (mV) 0.1mV\u003c\/li\u003e\n\u003cli\u003eResolution (pH) 0.1, 0.01, 0.001pH\u003c\/li\u003e\n\u003cli\u003eTemperature (English) Operating 41Ã‚Â° to 113Ã‚Â°F\u003c\/li\u003e\n\u003cli\u003eTemperature (Metric) Operating 5 to 45Ã‚Â°C\u003c\/li\u003e\n\u003cli\u003eAccuracy (Temperature) Ã‚Â±0.1Ã‚Â°C\u003c\/li\u003e\n\u003cli\u003eRange (Temperature) -5 to +105Ã‚Â°C\u003c\/li\u003e\n\u003cli\u003eResolution (Temperature) 0.1Ã‚Â°C\u003c\/li\u003e\n\u003cli\u003eWarranty 3 year meter replacement\u003c\/li\u003e\n\u003cli\u003eCertifications\/Compliance IP-54\u003c\/li\u003e\n\u003cli\u003eAdvanced ISE Functions Linear point to point, non-linear selectable auto-blank, incremental techniques including single known addition and subtraction, double known addition and subtraction\u003c\/li\u003e\n\u003cli\u003eCalibration Points (pH) 2 to 6\u003c\/li\u003e\n\u003cli\u003eCalibration Points (ISE) 1 to 6\u003c\/li\u003e\n\u003cli\u003eCalibration pH, ORP, relative mV, ISE\u003c\/li\u003e\n\u003cli\u003eHertz 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eIncludes DUAL STAR Meter with Electrode Stand; Universal Power Adapter; 8157BNUMD ROSS Ultra Epoxy Refillable pH\/ATC Triode Electrode\u003c\/li\u003e\n\u003cli\u003eRelative Humidity 5 to 85 %, non-condensing\u003c\/li\u003e\n\u003cli\u003eVoltage 90 to 260VAC\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041270075,"sku":"91-2654-22-EA","price":2650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-22_403507ea-a20d-4687-887d-7412cbe2d879.png?v=1784707762"},{"product_id":"dual-star-meter-with-electrode-stand-universal-power-adapter-927007md-stainless-steel-atc-probe","title":"Dual STAR Meter with Electrode Stand; Universal Power Adapter; 927007MD Stainless Steel ATC Probe","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Dual STAR™ Meter with Electrode Stand; Universal Power Adapter; 927007MD Stainless Steel ATC Probe, 2115000\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eView large, individual measurements on full screen display or quickly toggle to split screen display to view two measurements at same time\u003c\/li\u003e\n\u003cli\u003eMeasure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using meter’s two BNC, reference pin-tip and ATC temperature inputs\u003c\/li\u003e\n\u003cli\u003eMeter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so meter displays more accurate results faster\u003c\/li\u003e\n\u003cli\u003eEasy-to-follow on-screen text prompts for calibration and setup menus available in multi-language user interface with English, Spanish, French, German or Italian options\u003c\/li\u003e\n\u003cli\u003eEZ Startup menu facilitates quick and easy first-time meter setup\u003c\/li\u003e\n\u003cli\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/li\u003e\n\u003cli\u003eSelectable read modes include \u003cem\u003eAuto-Read\u003c\/em\u003e, \u003cem\u003eOn-Ready\u003c\/em\u003e, \u003cem\u003eAt Timed Intervals\u003c\/em\u003e, \u003cem\u003eContinuous\u003c\/em\u003e, \u003cem\u003eValue Change\u003c\/em\u003e \u003cem\u003ein Measurement\u003c\/em\u003e and \u003cem\u003eTimed\u003c\/em\u003e for variety of measurement collection methods for different analytical methods\u003c\/li\u003e\n\u003cli\u003ePerform up to 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/li\u003e\n\u003cli\u003ePerform up to 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eEasily transfer data via USB and RS232 to printer or computer with free Orion Dual Star Com™ communication software\u003c\/li\u003e\n\u003cli\u003eStir samples with ease using meter-controlled Orion Star stirrer probe\u003c\/li\u003e\n\u003cli\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e927007MD Orion stainless steel ATC probe\u003c\/li\u003e\n\u003cli\u003eElectrode stand\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eLiterature\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e                                                                                                                                               \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Adapter\u003c\/td\u003e\n\u003ctd\u003eUniversal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (ISE)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05 of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Temperature)\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (mV)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (pH)\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eLinear point to point, non-linear selectable auto-blank, incremental techniques including single known addition and subtraction, double known addition and subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e2 to 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\/Compliance\u003c\/td\u003e\n\u003ctd\u003eIP-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, L x W x H\u003c\/td\u003e\n\u003ctd\u003e24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e90 to 260 VAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH (adjustable), 1.000 ISE (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eNumeric with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and Timed Reading; manual data logging with Continuous measurement mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE\/mV\/RmV\/ORP\/Temperature Dual Channel Benchtop Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUniversal 90-260 VAC (included), 50-60 Hertz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProbe Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (ISE)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 19999 in ppm, M, %, ppb or unitless\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (ORP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (pH)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-2.000 to 19.999 pH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Relative Humidity)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 to 85 %, non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Relative mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5.0 °C to +105.0 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (ISE)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 3 significant digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (pH)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1, 0.01, 0.001 pH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (Temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSmart Stability and Smart Averaging\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature (English) Operating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e41 to 113 °F\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature (Metric) Operating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 to 45 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Probe Calibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 point temperature offset calibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Selection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManual or automatic with ATC temperature probe\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 year meter replacement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.9 kg (2 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041302843,"sku":"91-2654-23-EA","price":2560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-23_ee2cd231-5535-484d-a857-a9493e647a53.png?v=1784707763"},{"product_id":"orion-dual-star-meter-ph-and-ammonia-kit-thermo-scientific-2115201","title":"Orion Dual Star Meter pH and Ammonia Kit, Thermo Scientific 2115201","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e9512BNWP Orion Ammonia ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e951207 Orion 100 ppm ammonia standard (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e951211 Orion ammonia ISA ionic strength adjuster (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 612px; height: 891px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eNumeric with menu-specific function keys and dual purposescroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSmart Stability and Smart Averaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,Value Change in Measurement and Timed Reading measure modes,manual data logging with Continuous measure mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e1000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Adapter\u003c\/td\u003e\n\u003ctd\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eUniversal AC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e90 to 260Vac 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity  Range\u003c\/td\u003e\n\u003ctd\u003e5 to 85%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lb. (0.9kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification Compliance\u003c\/td\u003e\n\u003ctd\u003eCE, TU 3-1, FCC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041335611,"sku":"91-2654-24-EA","price":4070.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-24_ac43fd84-b631-4abf-80ef-f99963e33846.png?v=1784707765"},{"product_id":"orion-dual-star-meter-ph-and-chloride-kit-thermo-scientific-2115202","title":"Orion Dual Star Meter pH and Chloride Kit, Thermo Scientific 2115202","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e9617BNWP Orion Chloride ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e941708 Orion 1000 ppm chloride standard (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e940011 Orion chloride ISA ionic strength adjuster (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 612px; height: 891px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric with menu-specific function keys and dual purpose\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003escroll\/shortcut keys\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeasurement Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSmart Stability and Smart Averaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Management Details\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLog Function Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,Value Change in Measurement and Timed Reading measure modes,manual data logging with Continuous measure mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAlarm Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMethods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eInputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOutputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUSB, RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLanguages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEnglish, Spanish, French, Italian and German\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ehalf-cell electrode, ATC temperature probe, stirrer probe (includes \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAC Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal AC adapter (included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e90 to 260Vac 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP-54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRelative Humidity  Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e5 to 85%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 lb. (0.9kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCertification Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCE, TU 3-1, FCC Class A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041696059,"sku":"91-2654-25-EA","price":4230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-25.png?v=1784707766"},{"product_id":"orion-dual-star-meter-ph-and-fluoride-kit-thermo-scientific-2115203","title":"Orion Dual Star Meter pH and Fluoride Kit, Thermo Scientific 2115203","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e9609BNWP Orion Fluoride ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e040908 Orion 10 ppm fluoride standard premixed with TISAB II (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e040906 Orion 1 ppm fluoride standard premixed with TISAB II (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e940909 Orion TISAB II total ionic strength adjuster buffer (3.8L)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"border: 0px solid #000000; width: 612px; height: 891px;\" border=\"0\" frame=\"box\" rules=\"groups\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric with menu-specific function keys and dual purpose\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003escroll\/shortcut keys\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeasurement Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ewith temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSmart Stability and Smart Averaging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Management Details\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTransfer single, range or all data points to printer or computer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLog Function Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eValue Change in Measurement and Timed Reading measure modes,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emanual data logging with Continuous measure mode.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1000 with date and time stamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAlarm Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eHigh\/low limit alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile memory preserves data log, calibration log and \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emeter settings\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMethods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e10 per channel with password protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eInputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eelectrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e(stirrer probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOutputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUSB, RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLanguages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEnglish, Spanish, French, Italian and German\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ehalf-cell electrode, ATC temperature probe, stirrer probe (includes \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAC Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal AC adapter (included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e90 to 260Vac 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP-54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRelative Humidity  Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e5 to 85%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 lb. (0.9kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCertification Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCE, TU 3-1, FCC Class A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041761595,"sku":"91-2654-26-EA","price":4350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-26_440249be-101d-41d2-a4fd-8e4c73810f49.png?v=1784707768"},{"product_id":"orion-dual-star-meter-ph-and-nitrate-kit-thermo-scientific-2115204","title":"Orion Dual Star Meter pH and Nitrate Kit, Thermo Scientific 2115204","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e9707BNWP Orion Nitrate ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e930707 Orion 100 ppm nitrate standard (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e930711 Orion nitrate ISA ionic strength adjuster (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 612px; height: 891px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric with menu-specific function keys and dual purpose\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003escroll\/shortcut keys\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeasurement Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ewith temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSmart Stability and Smart Averaging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Management Details\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTransfer single, range or all data points to printer or computer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLog Function Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eValue Change in Measurement and Timed Reading measure modes,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emanual data logging with Continuous measure mode.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1000 with date and time stamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAlarm Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eHigh\/low limit alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile memory preserves data log, calibration log and \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emeter settings\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMethods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e10 per channel with password protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eInputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eelectrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e(stirrer probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOutputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUSB, RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLanguages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEnglish, Spanish, French, Italian and German\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ehalf-cell electrode, ATC temperature probe, stirrer probe (includes \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAC Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal AC adapter (included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e90 to 260Vac 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP-54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRelative Humidity  Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e5 to 85%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 lb. (0.9kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCertification Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCE, TU 3-1, FCC Class A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041859899,"sku":"91-2654-27-EA","price":4430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-27.png?v=1784707770"},{"product_id":"orion-dual-star-meter-ph-and-sodium-kit-thermo-scientific-2115205","title":"Orion Dual Star Meter pH and Sodium Kit, Thermo Scientific 2115205","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8611BNWP Orion Sodium ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e841108 Orion 1000 ppm sodium standard (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e841109 \u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion KAP sodium standard \u0026amp; ISA solution (475ml)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e841111 Orion sodium \u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e ISA ionic strength adjuster (475ml)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e841113 Orion sodium electrode conditioning solution (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e841101 Orion sodium electrode storage solution (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 612px; height: 891px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric with menu-specific function keys and dual purpose\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003escroll\/shortcut keys\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeasurement Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ewith temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSmart Stability and Smart Averaging\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Management Details\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTransfer single, range or all data points to printer or computer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLog Function Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eValue Change in Measurement and Timed Reading measure modes,\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emanual data logging with Continuous measure mode.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eData Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1000 with date and time stamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAlarm Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eHigh\/low limit alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile memory preserves data log, calibration log and \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003emeter settings\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMethods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e10 per channel with password protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eInputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eelectrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e(stirrer probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOutputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUSB, RS232\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eLanguages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEnglish, Spanish, French, Italian and German\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eProbe Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ehalf-cell electrode, ATC temperature probe, stirrer probe (includes \u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAC Adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eUniversal AC adapter (included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrical Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e90 to 260Vac 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP-54\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRelative Humidity  Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e5 to 85%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDimensions (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 lb. (0.9kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCertification Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCE, TU 3-1, FCC Class A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041892667,"sku":"91-2654-28-EA","price":3850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-28.png?v=1784707772"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/7030202.jpg?v=1761842899","url":"https:\/\/preiser.com\/collections\/ise-ph-meters-combo.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}