{"title":"Sulfur Analyzers","description":"\u003cp\u003eSulfur Analyzers\u003c\/p\u003e","products":[{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-1xc-0-05-100-c-includes-analyzer-computer-and-balance-eltra-88100-4015-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 1xC 0.05-100% C - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4015 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4015\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\"CS-580A 1xC 0.05-100% C - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148486971,"sku":"92-1204-01-EA","price":20576.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-01.png?v=1784710669"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4016-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4016 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4016 Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant,construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC(steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148519739,"sku":"92-1204-02-EA","price":22402.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-02.png?v=1784710670"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-2-cell-2xc-0-005-12-c-includes-analyzer-computer-and-balance-eltra-88100-4017-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 2 Cell 2xC 0.005-12% C - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4017 (Shown with Sample Autoloader attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4017\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 2 Cell 2xC 0.005-12% C - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant,construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC(steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148552507,"sku":"92-1204-03-EA","price":22939.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-03.png?v=1784710672"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-2-cell-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4018-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4018 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4018\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148585275,"sku":"92-1204-04-EA","price":35450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-04.png?v=1784710673"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-2-cell-1xc-0-05-100-c-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4019-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4019 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4019\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A series analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogeneous materials.  The analyzer has the capability of accommodating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148650811,"sku":"92-1204-05-EA","price":23398.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-05_c68a3c60-f041-4d9e-9cec-8203dd3d3da8.png?v=1784710674"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-3-cell-1xc-0-05-100-c-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4020-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4020 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4020\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant,construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148716347,"sku":"92-1204-06-EA","price":39900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-06_5729a2ac-b047-4111-b882-869225afe167.png?v=1784710676"},{"product_id":"carbon-sulfur-analyzer-in-helios-in-cs-580a-3-cell-2xc-0-005-12-c-12-100-c-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4021-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4021 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4021\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant,construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC(steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148749115,"sku":"92-1204-07-EA","price":27363.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-07.png?v=1784710677"},{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-4-cell-2xc-0-005-12-c-12-100-c-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4022-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 4 Cell 2xC 0.005-12% C + 12-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4022 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4022\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 4 Cell 2xC 0.005-12% C + 12-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant,construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC(steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148781883,"sku":"92-1204-08-EA","price":31283.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-08.png?v=1784710679"},{"product_id":"36-position-sample-autoloader-for-eltra-cs-580a-eltra-ar14535","title":"Eltra 36 Position Sample Autoloader for Eltra CS-580A, Verder Scientific,  14535","description":"\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eModel AR14535 36-Place Sample Autoloader for Eltra CS-580A series Carbon\/Sulfur Analyzers\u003c\/strong\u003eEltra has designed their CS-580A series Carbon\/Sulfur Analyzers to operate with automatic sample loaders.  These are available in either a 36-place or 130-place configuration and allow crucibles to be loaded automatically for hours of unsupervised operation.  The autoloaders are ergonomically designed and very compact.  Combined with the vertical resistance furnace of the CS-580A and crucibles, this system provides robust and fail-safe automated analyses.  Also, the autoloaders virtually eliminate damages to the furnace, for example by incorrectly adjusted grippers.\u003c\/span\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eAdditional Models:\u003c\/strong\u003e\u003c\/span\u003e\u003ctable style=\"border-color:\" solid rules=\"all\" frame=\"border\" align=\"center\" border=\"1\" border-width:=\"\" border-style:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003eMfg. Model No.\u003c\/strong\u003e   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cspan\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e\u003cstrong\u003e92-1204-09\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eAR14535\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e36-Position Autoloader\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cspan\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e\u003cstrong\u003e92-1204-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eAR14533\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e130-Position Autoloader   \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148814651,"sku":"92-1204-09-EA","price":6667.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-09.png?v=1784710680"},{"product_id":"130-position-sample-autoloader-for-eltra-cs-580a-eltra-ar14533","title":"Eltra 130 Position Sample Autoloader for Eltra CS-580A, Verder Scientific,  14533","description":"\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eModel AR14533 130-Place Sample Autoloader for Eltra CS-580A series Carbon\/Sulfur Analyzers\u003c\/strong\u003eEltra has designed their CS-580A series Carbon\/Sulfur Analyzers to operate with automatic sample loaders.  These are available in either a 36-place or 130-place configuration and allow crucibles to be loaded automatically for hours of unsupervised operation.  The autoloaders are ergonomically designed and very compact.  Combined with the vertical resistance furnace of the CS-580A and crucibles, this system provides robust and fail-safe automated analyses.  Also, the autoloaders virtually eliminate damages to the furnace, for example by incorrectly adjusted grippers.\u003c\/span\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eAdditional Models:\u003c\/strong\u003e\u003c\/span\u003e\u003ctable style=\"border-color:\" solid rules=\"all\" frame=\"border\" align=\"center\" border=\"1\" border-width:=\"\" border-style:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003eMfg. Model No.\u003c\/strong\u003e   \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"color:\" font-family: times new roman font-size: small\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cspan\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e\u003cstrong\u003e92-1204-09\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eAR14535\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e36-Position Autoloader\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cspan\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e\u003cstrong\u003e92-1204-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eAR14533\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e130-Position Autoloader   \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148880187,"sku":"92-1204-10-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-10_cf276d49-ad08-4b49-b731-6f91c1e639e4.png?v=1784710681"},{"product_id":"carbon-sulfur-analyzer-cs-580-1xc-0-05-100-c-includes-analyzer-computer-and-balance-eltra-88100-4001","title":"Eltra Carbon\/Sulfur Analyzer CS-580 1xC 0.05-100% C - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4001","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4001 Eltra Carbon\/Sulfur Analyzer CS-580 1xC 0.05-100% C - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149175099,"sku":"92-1210-01-EA","price":21417.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-01.png?v=1784710688"},{"product_id":"carbon-sulfur-analyzer-cs-580-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4002","title":"Eltra Carbon\/Sulfur Analyzer CS-580 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4002","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4002 Eltra Carbon\/Sulfur Analyzer CS-580 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149240635,"sku":"92-1210-02-EA","price":22952.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-02.png?v=1784710689"},{"product_id":"carbon-sulfur-analyzer-cs-580-2-cell-2xc-0-05-100-c-12-100-c-includes-analyzer-computer-and-balance-eltra-88100-4003","title":"Eltra Carbon\/Sulfur Analyzer CS-580 2 Cell 2xC 0.05-100% C + 12-100% C - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4003","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4001 Eltra Carbon\/Sulfur Analyzer CS-580 2 Cell 2xC 0.05-100% C + 12-100% C - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e The sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003e The sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Al\nignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149306171,"sku":"92-1210-03-EA","price":23520.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-03.png?v=1784710691"},{"product_id":"carbon-sulfur-analyzer-cs-580-2-cell-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4004","title":"Eltra Carbon\/Sulfur Analyzer CS-580 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4004","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4004 Eltra Carbon\/Sulfur Analyzer CS-580 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e The sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003e The sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149338939,"sku":"92-1210-04-EA","price":31719.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-04.png?v=1784710692"},{"product_id":"carbon-sulfur-analyzer-cs-580-2-cell-1xc-0-05-100-c-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4005","title":"Eltra Carbon\/Sulfur Analyzer CS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4005","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4005 Eltra Carbon\/Sulfur Analyzer CS-580  2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e The sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003e The sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149371707,"sku":"92-1210-05-EA","price":23929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-05.png?v=1784710693"},{"product_id":"carbon-sulfur-analyzer-cs-580-3-cell-1xc-0-05-100-c-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4006","title":"Eltra Carbon\/Sulfur Analyzer CS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4006","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4006 Eltra Carbon\/Sulfur Analyzer CS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149470011,"sku":"92-1210-06-EA","price":27457.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-06.png?v=1784710695"},{"product_id":"carbon-sulfur-analyzer-cs-580-3-cell-2xc-0-005-12-c-12-100-c-1xs-0-005-2-s-includes-analyzer-computer-and-balance-eltra-88100-4007","title":"Eltra Carbon\/Sulfur Analyzer CS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4007","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4007 Eltra Carbon\/Sulfur Analyzer CS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e The sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003e The sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149502779,"sku":"92-1210-07-EA","price":27457.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-07_426060eb-a973-4b54-bee1-76663122e584.png?v=1784710696"},{"product_id":"carbon-sulfur-analyzer-cs-580-4-cell-2xc-0-05-100-c-12-100-c-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4008","title":"Eltra Carbon\/Sulfur Analyzer CS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific, 88100-4008","description":"\u003cp\u003e\u003cstrong\u003eModel # 88100-4008 Eltra Carbon\/Sulfur Analyzer CS-580  4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580 Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe sample is weighed into ceramic boats and the weight is transferred from the interfaced balance to the PC or the weight can be entered manually.  The sample is loaded into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic boats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plants, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 20A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 80 x 60 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~70 kg (analyzer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for low carbon measurement, TIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-01\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4001\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4002\u003c\/td\u003e\n\u003ctd\u003eCS-580 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-03\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4003\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4004\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4005\u003c\/td\u003e\n\u003ctd\u003eCS-580 2 Cell 1xC 0.05-100% C + 1xS 0.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-06\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4006\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-07\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4007\u003c\/td\u003e\n\u003ctd\u003eCS-580 3 Cell 2xC 0.005-12% C + 12-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan style=\"text-decoration: underline; color: #3366ff;\"\u003e\u003cstrong\u003e92-1210-08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4008\u003c\/td\u003e\n\u003ctd\u003eCS-580 4 Cell 2xC 0.05-100% C + 12-100% C + 2xS 0.005-2% S + 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149535547,"sku":"92-1210-08-EA","price":30945.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1210-08_74168702-5d8d-421b-a329-bb831869c357.png?v=1784710697"},{"product_id":"eltra-elementrac-cs-r-analyzer-and-pc-system-configured-as-dual-infrared-sulfur-detection-unit-2-x-s-0-001-31-4-s-350-mg-sample-weight-verder-scientific-88200-3008","title":"Eltra Elementrac CS-r Analyzer and PC System, Configured as Dual Infrared Sulfur Detection Unit, 2 x S, 0.001 - 31.4 % S, 350 mg Sample Weight, Verder Scientific, 88200-3008","description":"\u003cp\u003e\u003cstrong\u003eVerder Scientific® Eltra® Elementrac® CS-r Analyzer and PC System, Configured as Dual Infrared Sulfur Detection Unit, 2 x S, 0.001 - 31.4 % S, 350 mg Sample Weight, 88200-3008\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHigh-performance carbon and sulfur analyzer for inorganic solid materials for simultaneous measurement of carbon and sulfur\u003c\/li\u003e\n\u003cli\u003eHigh sample weight possible\u003c\/li\u003e\n\u003cli\u003eOptimized (low blank) sample port\u003c\/li\u003e\n\u003cli\u003eIR path made of solid gold for extended lifetime\u003c\/li\u003e\n\u003cli\u003eWide measuring range from 20 ppm to 100%\u003c\/li\u003e\n\u003cli\u003eGas required: oxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi)\u003c\/li\u003e\n\u003cli\u003eChemicals required: magnesium perchlorate, sodium hydroxide\u003c\/li\u003e\n\u003cli\u003eConfiguration 88200-3008: Dual infrared sulfur detection (2×S cells) for extended dynamic range and sensitivity\u003c\/li\u003e\n\u003cli\u003eSimultaneous carbon (C) and sulfur (S) determination via high-temperature combustion\u003c\/li\u003e\n\u003cli\u003eWide analytical range:\u003cul\u003e\n\u003cli\u003eCarbon: trace levels up to high percentage concentrations\u003c\/li\u003e\n\u003cli\u003eSulfur: approx. 0.001% to 30%+ (method dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-frequency induction furnace ensures rapid and complete combustion of samples\u003c\/li\u003e\n\u003cli\u003eAdvanced IR detection system with automatic range switching for accurate results across broad concentration ranges\u003c\/li\u003e\n\u003cli\u003eDesigned for analysis of metals, ores, ceramics, cement, and other inorganic materials\u003c\/li\u003e\n\u003cli\u003eFast cycle times for high-throughput laboratory environments\u003c\/li\u003e\n\u003cli\u003eIntegrated automatic cleaning system reduces maintenance and downtime\u003c\/li\u003e\n\u003cli\u003eUser-friendly software control via external PC (included or specified separately) for:\u003cul\u003e\n\u003cli\u003eMethod setup and calibration\u003c\/li\u003e\n\u003cli\u003eReal-time data acquisition\u003c\/li\u003e\n\u003cli\u003eReporting and data export\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports LIMS connectivity and data traceability requirements\u003c\/li\u003e\n\u003cli\u003eModular design allows configuration flexibility and future upgrades\u003c\/li\u003e\n\u003cli\u003eRequires external PC, monitor, balance, and gases for operation (often supplied as complete system package)\u003c\/li\u003e\n\u003cli\u003eIdeal for quality control, research, and production laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAgriculture\u003c\/li\u003e\n\u003cli\u003eBiology\u003c\/li\u003e\n\u003cli\u003eChemistry\u003c\/li\u003e\n\u003cli\u003ePlastics\u003c\/li\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003cli\u003ePower plant\u003c\/li\u003e\n\u003cli\u003eConstruction materials\u003c\/li\u003e\n\u003cli\u003eEnvironment\u003c\/li\u003e\n\u003cli\u003eRecycling\u003c\/li\u003e\n\u003cli\u003eMedicine\u003c\/li\u003e\n\u003cli\u003ePharmaceuticals\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111149109563,"sku":"92-1208-01-EA","price":43147.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1208-01_2940cfa2-d6a0-4efd-b674-bd28d6893e45.png?v=1784710686"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/imgi_6_30705_531bdf7b-37c6-4b33-b87b-76678f844afc.jpg?v=1762275924","url":"https:\/\/preiser.com\/collections\/sulfur-analyzers.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}