{"title":"Total Organic Carbon Analyzer","description":"\u003cp\u003eTotal Organic Carbon Analyzer (TOC)\u003c\/p\u003e","products":[{"product_id":"total-organic-carbon-analyzer-toc-shimadzu-toc-l","title":"Total Organic Carbon Analyzer (TOC), Shimadzu, TOC-L","description":"\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eShimadzu Total Organic Carbon Analyzer, TOC-L Series\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cspan style=\"font-size:\" small\u003eThis series of TOC analyzer utilizes the Shimadzu-designed, global standard,  680 °C combustion catalytic oxidation\/non-dispersive infrared (NDIR) detection method and offers the optimum selection of performance features and options to meet the specific requirements for your TOC testing.  Samples from aqueous samples ranging from ultrapure water, drinking water, wastewater, brine water, and seawater to solid and gaseous samples (with optional equipment) can be analyzed.  The combustion catalytic oxidation method\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e allows analysis of both easy-to-decompose, low-molecular weight organic compounds and hard-to-decompose insoluble and macromolecular organic compounds.\u003c\/span\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-size:\" small\u003eFeatures:\u003c\/span\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cp\u003e\u003c\/p\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eExtremely wide measurement range from 4 µg\/L to 30,000 mg\/L with a detection limit of 4 µg\/L\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"font-size:\" small\u003eReliable sample injection system\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e with automatic sample acidification and sparging\u003c\/span\u003e\n\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eAutomatic sample dilution function to reduce salinity, acidity, and alkalinity which extends the use of catalysts and combustion tubes\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eStat or priority samples can be added at any time without interrupting operation even with an autosampler\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eMultiple models available from stand-alone or PC-controlled, high-sensitivity or standard models\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eOptions available to enhance functionality, such as, autosamplers, stirrer unit, TN (total nitrogen) unit, carrier gas purification unit, solid combustion unit, small sample volume kit, etc.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eSpace-saving and energy-saving design\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eAutomatic settings for optimal measurement conditions, optimal calibration curve, changing conditions, re-measurement of out-of range samples, exclusion of anamolies, re-calculation of repeated measurements, and sleep\/restart modes\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eApplications:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e  \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eEffluent treatment process control for wastewater, plating, industrial processes, water recyling\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eQuality control for drinking water, ultrapure water, boiler water, electronic components, raw materials, manufacturing, pharmaceuticals\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eEnvironmental monitoring for river, lakes and marshes, underground water, sea water, soil, sludge, sediments\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eBiodegradable plastics and cement secondary products\u003c\/span\u003e\u003c\/li\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003e\u003c\/p\u003e \u003ctable align=\"center\" style=\"border:\" solid border-image: none border=\"1\" rules=\"all\" frame=\"box\"\u003e   \u003ctbody\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eItems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"background-color:\" text-align: center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eHigh-sensitivity Model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"background-color:\" text-align: center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eStandard Model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eModels Available\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eTOC-L CPH\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eTOC-L CSH\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eTOC-L CPN\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eTOC-L CSN\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eMeasurement Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003e680 °C combustion catalytic oxidation—non-dispersive\u003cbr\u003e infrared detection (NDIR) method\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eOperation \u003cbr\u003eMethod\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003ePC-controlled\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eStand-alone (PC control available)\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003ePC-controlled\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eStand-alone (PC control available)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eMeasured \u003cbr\u003eItems\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003eTC, IC, TOC (= TC - IC), NPOC (TOC measurement \u003cbr\u003evia acidification and sparging) Optional: POC,\u003cbr\u003e TOC (= NPOC + POC), TN\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e        \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eDetection \u003cbr\u003eLimit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003eTC, IC: 4 µg\/L, TN: 5 µg\/L\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003eTC: 50 µg\/L, IC: 4 µg\/L, TN: 20 µg\/L\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eReproducibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\n\u003cspan style=\"font-size:\" small\u003eTC, IC, NPOC: CV \u003cbr\u003e1.5% max. or ±4 \u003cbr\u003eµg\/L max \u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e(Optional TN: \u003cbr\u003eCV 3.0% max. or ±5 \u003cbr\u003eµg\/L max)\u003c\/span\u003e\n\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\n\u003cspan style=\"font-size:\" small\u003eTC, NPOC: CV 1.5% max. \u003cbr\u003eor ±50 µg\/L max, IC: \u003cbr\u003eCV 1.5% max. or ±4 µg\/L\u003cbr\u003e max \u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e(Optional TN: \u003cbr\u003eCV 3.0% max. or \u003cbr\u003e±20 µg\/L max)\u003c\/span\u003e\n\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eMeasuring \u003cbr\u003eTime\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003eTC: approx. 3 min, IC: \u003cbr\u003eapprox. 3 min (Optional \u003cbr\u003eTN: approx. 4 min)\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003eTC: approx. 3 min, IC: \u003cbr\u003eapprox. 4 min (Optional \u003cbr\u003eTN: approx. 4 min)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSample \u003cbr\u003eInjection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003eAutomatic sample injection using a syringe pump \u003cbr\u003eand slide type injection mechanism\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSample \u003cbr\u003eInjection \u003cbr\u003eVolume\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003e10 to 2,000 µL variable\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003eTC: 10 to 150 µL variable, \u003cbr\u003eIC: 10 to 4,500 µL variable\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eIC Removal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003eAutomatic addition of acid and sparging\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSample\u003cbr\u003e Dilution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003eDilution rate of 2x to 50x (automatic sample dilution \u003cbr\u003eby syringe pump), dilution accuracy: ±2% max.\u003cbr\u003e (2x to 20x), ±5% max. (21x to 50x)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eDisplay and Operations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eOperated by PC\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eOperation by color LCD screen and keyboard (operation by PC is also possible)\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eOperated by PC\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eOperation by color LCD screen and keyboard (operation by PC is also possible)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eExternal Memory (stand-alone\u003cbr\u003e type)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003e—\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eUSB flash memory used\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003e—\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center\u003e\u003cspan style=\"font-size:\" small\u003eUSB flash memory used\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003ePrinter (stand-alone type)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003ePortable thermal printer and PC   USB printer can be used\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eCarrier Gas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\n\u003cspan style=\"font-size:\" small\u003eHigh-purity air (CO, CO2, HC content: Each 1 ppm max., \u003cbr\u003edew point: -50 ºC max.)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:\" small\u003eSupply pressures: 200 ±10 kPa (additional use of \u003cbr\u003eoptional carrier gas regulator: 300 to 600 kPa)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-size:\" small\u003eOptional use of nitrogen gas (not possible in the TN\u003cbr\u003e measurement). With the standard model, optional \u003cbr\u003euse of pressurized gas.\u003c\/span\u003e\n\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eGas \u003cbr\u003eConsumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003e150 mL\/min (230 to 250 \u003cbr\u003emL\/min during sparging) \u003cbr\u003e(Variable flow rate)\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"2\"\u003e\u003cspan style=\"font-size:\" small\u003e230 mL\/min (A separate \u003cbr\u003e100 mL\/min is required for \u003cbr\u003esparging with ASI-L.) \u003cbr\u003e(Variable flow rate)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e         \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eDimensions, WxDxH\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003e340 x 660 x 480 mm (Excluding protrusions.  For details, \u003cbr\u003esee External Dimensions Diagram)\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e     \u003ctr\u003e       \u003ctd style=\"background-color:\"\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e       \u003ctd style=\"text-align:\" center colspan=\"4\"\u003e\u003cspan style=\"font-size:\" small\u003eApprox. 35 kg\u003c\/span\u003e\u003c\/td\u003e     \u003c\/tr\u003e   \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\u003c\/span\u003e","brand":"Shimadzu","offers":[{"title":"EA (1)","offer_id":51111191085371,"sku":"92-1632-01-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1632-01.png?v=1784711621"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/imgi_8_70708.jpg?v=1762273994","url":"https:\/\/preiser.com\/collections\/total-organic-carbon-analyzer.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}