{"title":"Turbidity Meter","description":"\u003cp\u003eTurbidity Meter\u003c\/p\u003e","products":[{"product_id":"tu5200-laboratory-laser-turbidimeter-without-rfid-epa-version-hach-lpv442-99-01012","title":"TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version, HACH, LPV442.99.01012","description":"\u003cp\u003e\u003cstrong\u003eHACH® TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version, LPV442.99.01012\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEmploys patented optical design that sees more of sample than any other turbidimeter, delivering best low level precision and sensitivity while minimizing variability from test to test\u003c\/li\u003e\n\u003cli\u003eRemove uncertainty of measurement thanks to identical 360° x 90° Detection Technology\u003c\/li\u003e\n\u003cli\u003eTU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of sample meaning no need to apply silicone oil to vial and index to ensure an accurate reading\u003c\/li\u003e\n\u003cli\u003eConsistent results in lab, from operator to operator, since impact of small interferences is minimized due to collection of light at 360°.\u003c\/li\u003e\n\u003cli\u003eOnly new TU5 Series Lab \u0026amp; Process Turbidimeters with 360° x 90° Detection delivers unprecedented confidence that change in reading is change in water quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTU5200 benchtop turbidimeter\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003cli\u003eStablcal kit (10, 20 and 600 NTU)\u003c\/li\u003e\n\u003cli\u003e2 sample vials\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003cli\u003eVial stand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2 % plus 0.01 NTU from 0 - 40 NTU; \u003cbr\u003e±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eFor Formazin and Stablcal: \u003cbr\u003e20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range\u003cbr\u003e\u003cbr\u003eCustom calibration for up to 6-point calibrations\u003cbr\u003e\u003cbr\u003eDegrees 0 - 100 mg\/L\u003cbr\u003eSDVB 0 - 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE compliant\u003cbr\u003eUS FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version\u003cbr\u003eComplies with IEC\/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)\u003cbr\u003eAustralian ACMA Marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7\" WVGA (800 x 480) color TFT-LCD with touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Construction\u003c\/td\u003e\n\u003ctd\u003ePC\/ABS Blend Plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eClass 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC\/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU5200 EPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory\u003c\/td\u003e\n\u003ctd\u003eEPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater\u003cbr\u003e\u0026gt;40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 NTU \/ FNU \/ TE\/F \/ FTU \/ EBC \/ mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eSignal averaging off: 7 seconds\u003cbr\u003eSignal averaging on: 10 seconds (when averaging time is 5 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Temperature\u003c\/td\u003e\n\u003ctd\u003e4 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Lamp\u003c\/td\u003e\n\u003ctd\u003e650 nm Class 2 Laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-30 - 60 °C (-22 - 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mNTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eNTU, FNU, TE\/F, FTU, EBC;\u003cbr\u003e\u003cbr\u003emg\/L if calibrated with Degrees calibration curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51184687808827,"sku":"92-2450-06-EA","price":6177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-06_fd724104-8cac-4086-9e97-053ab3070610.png?v=1784711968"},{"product_id":"orion-aquafast-turbidity-meter-kit-thermo-scientific-aq3010","title":"Orion AQUAfast Turbidity Meter Kit, Thermo Scientific AQ3010","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ AQUAfast™ Turbidity Meter Kit, AQ3010\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGenerate an accurate turbidity readings in seconds with simple turbidity meter that offers an impressive array of features\u003c\/li\u003e\n\u003cli\u003eResults are easy to read and record from the large, bright LCD display in a variety of work environments\u003c\/li\u003e\n\u003cli\u003eErgonomic IP67 turbidity meter for lab or field use\u003c\/li\u003e\n\u003cli\u003eAutoranging from 0 to 1000 NTUs\u003c\/li\u003e\n\u003cli\u003eUses Nephelometric principle with 90° detection\u003c\/li\u003e\n\u003cli\u003eSeparate light cap or shield is not needed in many locations\u003c\/li\u003e\n\u003cli\u003eMeets ISO 7027 and offers consistent light source for greater accuracy\u003c\/li\u003e\n\u003cli\u003eNo mixing or diluting with EPA-approved polymer bead primary standards for faster calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\t\n\n\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eISO 7027 compliant nephelometric\u003cbr\u003emethod (90 °)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eInfrared LED (for ISO 7027 Turbidity measurement) (850 nm wavelength)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1,000,000 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photovoltaic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4 digit 14 segments customized liquid crystal display with annunciators (LCD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Range Selection\u003c\/td\u003e\n\u003ctd\u003e0.01 to 19.99 NTU\u003cbr\u003e20.0 to 99.9 NTU\u003cbr\u003e100 to 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 NTU (0 to 19.99 NTU)\u003cbr\u003e0.1 NTU (20 to 99.9 NTU)\u003cbr\u003e1 NTU (100 to 1000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecision\u003c\/td\u003e\n\u003ctd\u003e±2% of reading ±1 LSD for 0-500 NTU, ±3% of reading ±1 LSD for 501-1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;6 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e0.02 NTU, 20 NTU, 100 NTU, 800 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandardization\u003c\/td\u003e\n\u003ctd\u003eEPA approved polymer-based primary\u003cbr\u003estandards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey Functions\u003c\/td\u003e\n\u003ctd\u003ePower, Cal, Scroll Up, Scroll Down, Read\/Enter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1200 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Requirement\u003c\/td\u003e\n\u003ctd\u003e10 mL (0.33 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Vials\u003c\/td\u003e\n\u003ctd\u003eGlass vials with screw caps, fill line and\u003cbr\u003eindexing mark, 51 (H) x 25 (Dia) mm ( 2 x 1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Conservation Feature\u003c\/td\u003e\n\u003ctd\u003eAuto shutoff after 20 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Diagnostics\u003c\/td\u003e\n\u003ctd\u003eYes, with trouble shooting error codes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Rating\u003c\/td\u003e\n\u003ctd\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAQUAfast™ Turbidity Meter, AQ3010\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-2450-17\u003c\/span\u003e\u003c\/span\u003e (Orion™ AC301S) Primary EPA-approved Turbidity Standards (0.02, 20.0, 100, and 800 NTU)\u003c\/li\u003e\n\u003cli\u003e4 x 25 mm standard vials\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-2450-19\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ AC3V25) 3 x 25 mm sample vials\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-2450-21\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ AC3SIL) silicone oil and lint-free cloth\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-2450-20\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ AC3CBR) vial cleaning brush\u003c\/li\u003e\n\u003cli\u003eLight shield cover\u003c\/li\u003e\n\u003cli\u003eUser guide\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184687907131,"sku":"92-2450-16-EA","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-16_5eca4f81-786c-44c1-b260-a8f5938b7c4b.png?v=1784711970"},{"product_id":"turbidity-meter-kit-portable-logging-iso-compliant-for-field-measurements-hanna-instruments-hi93703c","title":"Turbidity Meter Kit, Portable, Logging ISO Compliant, for Field Measurements, Hanna Instruments, HI93703C","description":"\u003cp\u003e\u003c\/p\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e \u003cp\u003e \u003c\/p\u003e \u003cul style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eGLP Features\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e3 point calibration\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eTwo-year warranty\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e \u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.\u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eHANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"spec_table\" style=\"color: #000000; font-family: Tahoma,Arial,FreeSans,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 18px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; word-spacing: 0px; width: 75%; border: 1px solid #000000;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.00 to 50.00 FTU;\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e50 to 1000 FTU\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.01 FTU (0.00 to 50.00 FTU);\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e1 FTU (50 to 1000 FTU)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e3 points (0 FTU, 10 FTU and 500 FTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003einfrared LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eSilicon Photocell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e510 g (1.1 lb.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703 Turbidity Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGlass Cuvette\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eBatteries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eInstructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMaintenance Kit which includes:\u003c\/span\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eRugged carrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703-0 Calibration Solution (0 FTU Solution)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93102-10 Calibration Solution (10 FTU Solution)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703-50 Cuvette Cleaning Solution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eCuvettes (2)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eCuvette Cleaning Cloth\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111210713403,"sku":"92-2450-27-EA","price":1299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-27.png?v=1784711980"},{"product_id":"turbidity-meter-epa-compliant-portable-kit-hanna-instruments-hi98703-01","title":"Turbidity Meter, EPA Compliant Portable Kit, Hanna Instruments, HI98703-01","description":"\u003cp class=\"TabbedPanelsContent\" tabbedpanelscontentvisible style=\"display:\" block\u003e\u003c\/p\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e \u003cp class=\"TabbedPanelsContent\" tabbedpanelscontentvisible style=\"display:\" block\u003e \u003c\/p\u003e \u003cul style=\"margin:\" tahoma arial freesans helvetica sans-serif normal auto start none color:=\"\" font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eHigh accuracy at low ranges (below 0.05 NTU)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eTwo, three or four point calibration\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eUSB and RS232 PC connectivity\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eLog up to 200 records\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eGLP Features\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eUser friendly, backlit  display with guidance codes\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eBattery % on startup\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eContinuous current time on display\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"TabbedPanelsContent\" tabbedpanelscontentvisible style=\"display:\" block\u003e \u003c\/p\u003e \u003cp class=\"TabbedPanelsContent\" tabbedpanelscontentvisible style=\"display:\" block\u003e\u003c\/p\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003eThe new HI 98703 portable Turbidity Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for turbidity.  The unit meets and exceeds the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water.  The instrument's EPA compliance reading mode rounds readings to meet EPA reporting requirements.  Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.\u003c\/span\u003e \u003cp class=\"TabbedPanelsContent\" tabbedpanelscontentvisible style=\"display:\" block\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eTurbidity is measured up to 1000 NTU. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging.  For advanced field operations, the HI 98703 has Fast Tracker™ and can be equipped with HANNA's Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data, up to 200 measurements, can be downloaded to a PC through either USB or RS232 connections using HANNA's optional HI 92000 software. \u003c\/span\u003e\u003c\/p\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003eA two, three or four-point calibration is available using pre-set or user defined standards. Frequent calibration isn't necessary as the system compensates for variations in the intensity of the light source. The instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instruments is equipped with backlighting. The current date and time can be displayed on the LCD.\u003c\/span\u003e \u003cp\u003e \u003c\/p\u003e \u003cp align=\"center\"\u003e \u003c\/p\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e\n\u003ctable class=\"spec_table\" style=\"width: 75%; border: 1px solid #000000;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eRange Selection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eAutomatic\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e±2% of reading plus 0.02 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e±1% of reading or 0.02 NTU, whichever is greater\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u0026lt; 0.02 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eTypical EMC Deviation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e±0.05 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eSilicon Photocell\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eRatio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eMeasuring mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eNormal, Average, Continuous\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eTurbidity Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e1, 10, 100 and 750 NTU\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eTwo, three or four-point calibration\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eTungsten filament lamp\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLamp life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGreater than 100,000 readings\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e60 x 90 mm LCD with back light\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLogging Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e200 records\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eUSB 1.1 or RS 232\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eTo 50°C (122°F); max 95% RH non-condensing\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e(4) 1.5V AA alkaline batteries or AC adapter\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eAfter 15 minutes of non-use\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e512 g (18 oz.)\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e \u003cstrong\u003eSupplied With:\u003cbr\u003e \u003c\/strong\u003e\u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 98703-01 turbidity meter (115V)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eSample cuvettes and caps (5)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 98703-11 calibration cuvettes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703-58 silicone oil\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ecuvette cleaning cloth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003ebatteries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eAC adapter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003einstruction manual\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003erugged carrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eInstrument Quality Certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 92000 tag holders and tags (5)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"display: block;\"\u003e \u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111210746171,"sku":"92-2450-34-EA","price":1299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-34.png?v=1784711981"},{"product_id":"epa-compliant-benchtop-turbidity-meter-hanna-instruments-hi88703-01","title":"EPA Compliant Benchtop Turbidity Meter, Hanna Instruments, HI88703-01","description":"\u003cp\u003e\u003cstrong\u003eHanna Instruments® EPA Compliant Benchtop Turbidity Meter, Hanna Instruments, HI88703-01\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eHigh accuracy (±2% of reading plus 0.02 NTU) Turbidity Benchtop Meter—EPA Compliant\u003c\/li\u003e \u003cli\u003eSupplied complete with HI98703-11 (\u003cspan\u003e\u003cspan style=\"text-decoration:\" underline color:\u003e91-2599-15\u003c\/span\u003e\u003c\/span\u003e) AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification\u003c\/li\u003e \u003cli\u003eTwo, three, four, or five-point turbidity calibration\u003c\/li\u003e \u003cli\u003eMeets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements\u003c\/li\u003e \u003cli\u003eBased on state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences\u003c\/li\u003e \u003cli\u003eRatio mode range: 0.00 to 4000 NTU and non-ratio mode range: 0.00 to 40.0 NTU\u003c\/li\u003e \u003cli\u003eUp to 200 measurements can be stored in the internal memory or transferred via USB to PC with Windows® compatable software\u003c\/li\u003e \u003cli\u003eOn board tutorial mode and dedicated HELP button\u003c\/li\u003e \u003cli\u003eBacklit graphic LCD display\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eNTU ratio Resolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0.01; 0.1; 1 NTU0.1; 1 Nephelos0.01; 0.1, 1 EBC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eNTU non ratio Resolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0.01; 0.1 NTU 0.1; 1 Nephelos 0.01 EBC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRange Selection\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAutomatic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTurbidity Repeatability\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.02 NTU (0.15 Nephelos; 0.01 EBC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTurbidity Light Detector\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSilicon Photocell\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTurbidity Method\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNephelometric method (90°) or Ratio Nephelometric Method (90° \u0026amp; 180°)Adaptation of the USEPA Method 180.1 and Standard Method 2130 B.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMeasuring mode\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNormal, Average, Continuous\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTurbidity Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u0026lt;0.1, 15, 100, 750 and 2000 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTwo, three, four or five-point calibration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTungsten filament lamp\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eLamp Life\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003egreater than 100,000 readings\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e40 x 70 mm graphic LCD (64 x 128 pixels) with backlight\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eLOG Memory\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e200 records\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAuto Shut-Off\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAfter 15 minutes of non-use\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111210811707,"sku":"92-2450-40-EA","price":2499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-40.png?v=1784711982"},{"product_id":"tb-300-ir-without-lithium-battery-lovibond-194000","title":"TB 300 IR Without Lithium Battery, Lovibond, 194000","description":"\u003cp\u003e\u003cstrong\u003eLovibond® Tintometer® TB 300 IR Without Lithium Battery, 194000\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMeets EN ISO 7027 by nephelometric means (90° scattered light)\u003c\/li\u003e \u003cli\u003eInfrared light-source permits measurement of colored and color-free samples\u003c\/li\u003e \u003cli\u003eAutomatic overall range adjustment Autorange) enables direct turbidity measurement from 0.01 to 1100 NTU with an accuracy of ± 2 % up to 500 NTU and ± 5 % thereafter\u003c\/li\u003e \u003cli\u003eCalibration with Standard-Set T-Cal\u003c\/li\u003e \u003cli\u003eAutoranging\u003c\/li\u003e \u003cli\u003eHigh accuracy\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInstrument in carrying case\u003c\/li\u003e \u003cli\u003e1 Set of turbidity standards T-CAL\u003c\/li\u003e \u003cli\u003eMains charger 100-240 V\u003c\/li\u003e \u003cli\u003ePC Connection cable\u003c\/li\u003e \u003cli\u003e4 Vials (ø 24 mm) with lids\u003c\/li\u003e \u003cli\u003eWarranty information\u003c\/li\u003e \u003cli\u003eCertificate of Compliance\u003c\/li\u003e \u003cli\u003eInstruction Manual\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eDrinking Water Treatment\u003c\/li\u003e \u003cli\u003ePool Water Control\u003c\/li\u003e \u003cli\u003ePool Water Treatment\u003c\/li\u003e \u003cli\u003eWaste Water Treatment\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eOptics\u003c\/td\u003e \u003ctd\u003eTurbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasuring Principle\u003c\/td\u003e \u003ctd\u003enephelometric (90° scattered light)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSuitable Vials\u003c\/td\u003e \u003ctd\u003eRound Cuvettes 24 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003eGraphic-Display\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperation\u003c\/td\u003e \u003ctd\u003eacid and solvent resistant; membrane keypad\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCalibration\u003c\/td\u003e \u003ctd\u003eautomatic overall range adjustment with Standard-Set T-Cal\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInternal Storage\u003c\/td\u003e \u003ctd\u003e1000 data sets\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e7 NiMH-battery pack (AA\/Mignon) Lithium battery must be purchased separately\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eClock\u003c\/td\u003e \u003ctd\u003eReal Time Clock\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePortability\u003c\/td\u003e \u003ctd\u003eBenchtop\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Lovibond","offers":[{"title":"EA (1)","offer_id":51184688169275,"sku":"92-2451-10-EA","price":2710.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2451-10.png?v=1784711986"},{"product_id":"turbidimeter-tb350-ir-kit-lovibond-194300","title":"Turbidimeter, TB350 IR  Kit, Lovibond, 194300","description":"\u003cp\u003e\u003cstrong\u003eLovibond® Turbidimeter, TB350 IR Kit, Portable, 194300\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eIdeal for field and environmental testing\u003c\/li\u003e \u003cli\u003eDelivers most reliable measurements for low range to high range samples without sacrificing accuracy\u003c\/li\u003e \u003cli\u003eOffers simplistic operation combined with intelligent instrument engineering to provide unparalleled level of accuracy in turbidity measurement\u003c\/li\u003e \u003cli\u003eFeaturing patent-pending Multipath 90° BLAC® sensor technology, optical system is engineered with dual detectors to deliver ratio reading which mitigates common measurement stability issues\u003c\/li\u003e \u003cli\u003eIntuitive, touchscreen interface makes it easy to perform procedures and interpret results\u003c\/li\u003e \u003cli\u003eWith function applications, user can navigate between settings and performthat function efficiently\u003c\/li\u003e \u003cli\u003eUser interface helps eliminates common frustrations and prevents errors\u003c\/li\u003e \u003cli\u003eData logging capabilities allow instrument to record testing location, operator’s identification, time and date along with measurement\u003c\/li\u003e \u003cli\u003eStored data can be transferred to a computer via USB\u003c\/li\u003e \u003cli\u003eReads up to 4000 NTU without the need for dilutions\u003c\/li\u003e \u003cli\u003eSuperior data management - easily save and recall measurement data sets\u003c\/li\u003e \u003cli\u003eISO 7027 Compliant\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eTB350 IR in case\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-34\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 197655) 2 cuvettes with lids\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-36\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 197635) Cleaning cloth for cuvettes\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-37\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 380230) Cleaning brush\u003c\/li\u003e \u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e92-2451-35\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 194295) Silicon oil, 15 mL\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-30\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 1950025) 4 Batteries (AA)\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 194154) T-Cal® Standards Set B: \u003cul\u003e \u003cli\u003e1 T-CAL®-Standard, 5 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 20 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 800 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 4000 NTU\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eScrew driver\u003c\/li\u003e \u003cli\u003eQuick Start Guide\u003c\/li\u003e \u003cli\u003eTest Certificate T-CAL®\u003c\/li\u003e \u003cli\u003eWarranty information\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eModel WM-040-1004 (IR)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLight Source\u003c\/td\u003e \u003ctd\u003eIR LED (860 nm)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRegulatory Compliance\u003c\/td\u003e \u003ctd\u003eISO 7027\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasuring Principle\u003c\/td\u003e \u003ctd\u003eNephelometric (Multipath 90° BLAC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasuring Range\u003c\/td\u003e \u003ctd\u003e0.01 - 4000 NTU (FNU)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e± 1.8 % of reading + straylight\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray Light\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.014 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Units\u003c\/td\u003e \u003ctd\u003eNTU, FNU, Degrees, mg\/L Kaolin, mg\/L PSL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReading Modes\u003c\/td\u003e \u003ctd\u003eSingle, Signal Averaging, Fast-Settling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCalibration Options\u003c\/td\u003e \u003ctd\u003eFull-range calibration from 0 - 4000 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetector\u003c\/td\u003e \u003ctd\u003eSilicon Photodiode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSample Required\u003c\/td\u003e \u003ctd\u003e10 mL (0.4 oz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003eFull-Colour Touchscreen\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Size\u003c\/td\u003e \u003ctd\u003e55 x 95 mm (W x H)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInterfaces\u003c\/td\u003e \u003ctd\u003eUSB-A, USB-C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Logger\u003c\/td\u003e \u003ctd\u003e250 measurements, all calibrations, verifications and factory-restore actions\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Transfer Format\u003c\/td\u003e \u003ctd\u003e.csv\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e4 batteries (AA), 3 NiMH-battery pack (AA) orUniversal (90 - 240 VAC), via external power supply\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCompliance\u003c\/td\u003e \u003ctd\u003eCE, CSA, FCC, RoHS, TÜV, UL, WEE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages User Interface\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Portuguese, Chinese, Japanese, Dutch, Turkish, Polish\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages Quick Start Guide\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages Full User Manual\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e6.1 x 3.27 x 8.86\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e804 g (898 g with four AA alkaline batteries)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight with Packaging\u003c\/td\u003e \u003ctd\u003e(898 g with four AA alkaline batteries)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Lovibond","offers":[{"title":"EA (1)","offer_id":51184688234811,"sku":"92-2451-26-EA","price":2031.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2451-26_f069595d-3873-4293-8414-59803b739793.png?v=1784711990"},{"product_id":"turbidimeter-tb350-wl-kit-lovibond-194310","title":"Turbidimeter, TB350 WL Kit, Lovibond, 194310","description":"\u003cp\u003e\u003cstrong\u003eLovibond® Turbidimeter, TB350 WL Kit, Portable, 194310\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eIdeal for field and environmental testing\u003c\/li\u003e \u003cli\u003eDelivers most reliable measurements for low range to high range samples without sacrificing accuracy\u003c\/li\u003e \u003cli\u003eOffers simplistic operation combined with intelligent instrument engineering to provide an unparalleled level of accuracy in turbidity measurement\u003c\/li\u003e \u003cli\u003eFeaturing patent-pending Multipath 90° BLAC® sensor technology\u003c\/li\u003e \u003cli\u003eOptical system is engineered with dual detectors to deliver ratio reading which mitigates common measurement stability issues\u003c\/li\u003e \u003cli\u003eIntuitive, touchscreen interface makes it easy to perform procedures and interpret results\u003c\/li\u003e \u003cli\u003eWith function applications, user can navigate between settings and perform function efficiently\u003c\/li\u003e \u003cli\u003eUser interface helps eliminates common frustrations and prevents errors\u003c\/li\u003e \u003cli\u003eData logging capabilities allow instrument to record testing location, operator’s identification, time and date along with measurement\u003c\/li\u003e \u003cli\u003eStored data can be transferred to computer via USB\u003c\/li\u003e \u003cli\u003eReads up to 4000 NTU without need for dilutions\u003c\/li\u003e \u003cli\u003eSuperior data management - easily save and recall measurement data sets\u003c\/li\u003e \u003cli\u003eTouchscreen interface for ease of operation\u003c\/li\u003e \u003cli\u003eUS EPA Approved\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eTB350 WL in case\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-34\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 197655) 2 cuvettes with lids\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-36\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 197635) Cleaning cloth for cuvettes\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-37\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 380230) Cleaning brush\u003c\/li\u003e \u003cli\u003e\n\u003cspan\u003e\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e92-2451-35\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 194295) Silicon oil, 15 mL\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-30\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 1950025) 4 Batteries (AA)\u003c\/li\u003e \u003cli\u003e\n\u003cspan style=\"text-decoration:\" underline\u003e\u003cspan style=\"color:\" text-decoration: underline\u003e\u003cspan\u003e92-2451-28\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Lovibond® 194152) T-Cal® Standards Set A: \u003cul\u003e \u003cli\u003e1 T-CAL®-Standard, 5 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 20 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 800 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 2000 NTU\u003c\/li\u003e \u003cli\u003e1 T-CAL®-Standard, 4000 NTU\u003c\/li\u003e \u003c\/ul\u003e \u003c\/li\u003e \u003cli\u003eScrew driver\u003c\/li\u003e \u003cli\u003eQuick Start Guide\u003c\/li\u003e \u003cli\u003eTest Certificate T-CAL®\u003c\/li\u003e \u003cli\u003eWarranty information\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eModel\u003c\/td\u003e \u003ctd\u003eModel WM-040-1001 (WL)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLight Source\u003c\/td\u003e \u003ctd\u003eWhite LED\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRegulatory Compliance\u003c\/td\u003e \u003ctd\u003eEPA approved (alternative to US EPA 180.1)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasuring Principle\u003c\/td\u003e \u003ctd\u003eNephelometric (Multipath 90° BLAC)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMeasuring Range\u003c\/td\u003e \u003ctd\u003e0.01 - 4000 NTU (FNU)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAccuracy\u003c\/td\u003e \u003ctd\u003e± 1.8 % of reading + straylight\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStray Light\u003c\/td\u003e \u003ctd\u003e\u0026lt; 0.014 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Units\u003c\/td\u003e \u003ctd\u003eNTU, FNU, Degrees, mg\/L Kaolin, mg\/L PSL\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eReading Modes\u003c\/td\u003e \u003ctd\u003eSingle, Signal Averaging, Fast-Settling\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCalibration Options\u003c\/td\u003e \u003ctd\u003eFull-range calibration from 0 - 4000 NTU\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDetector\u003c\/td\u003e \u003ctd\u003eSilicon Photodiode\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSample Required\u003c\/td\u003e \u003ctd\u003e10 mL (0.4 oz)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay\u003c\/td\u003e \u003ctd\u003eFull-Colour Touchscreen\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Size\u003c\/td\u003e \u003ctd\u003e55 x 95 mm (W x H)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInterfaces\u003c\/td\u003e \u003ctd\u003eUSB-A, USB-C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Logger\u003c\/td\u003e \u003ctd\u003e250 measurements, all calibrations, verifications and factory-restore actions\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Transfer Format\u003c\/td\u003e \u003ctd\u003e.csv\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e4 batteries (AA), 3 NiMH-battery pack (AA), or Universal (90 - 240 VAC), via external power supply\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCompliance\u003c\/td\u003e \u003ctd\u003eCE, CSA, FCC, RoHS, TÜV, UL, WEE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages User Interface\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Portuguese, Chinese, Japanese, Dutch, Turkish, Polish\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages Quick Start Guide\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLanguages Full User Manual\u003c\/td\u003e \u003ctd\u003eGerman, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions\u003c\/td\u003e \u003ctd\u003e6.1 x 3.27 x 8.86\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e804 g (898 g with four AA alkaline batteries)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight with Packaging\u003c\/td\u003e \u003ctd\u003e(898 g with four AA alkaline batteries)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Lovibond","offers":[{"title":"EA (1)","offer_id":51184688431419,"sku":"92-2451-27-EA","price":2031.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2451-27.png?v=1784711995"},{"product_id":"micro100-wl-laboratory-turbidimeter-0-1000-ntu-100-240-v-50-60-hz-hf-scientific-19950","title":"Micro100 WL Laboratory Turbidimeter, 0-1000 NTU, 100-240 V, 50-60 Hz, HF Scientific, 19950","description":"\u003cp\u003e\u003cstrong\u003eHF Scientific® Micro100 WL Laboratory Turbidimeter, 100-240 VAC, 50-60 Hz, 19950\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Micro 100 Lab Turbidimeter is an ideal and affordable tool for research as well as routine analytical measurements. It is designed to provide the accuracy demanded by today's scientist and is ready to meet the challenge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstrument senses turbidity level of sample and automatically adjusts to the appropriate measurement\u003c\/li\u003e\n\u003cli\u003eAutomatically prompts the operator when calibration of the instrument is needed\u003c\/li\u003e\n\u003cli\u003eCalibration initiated with the push of a button ensures accurate readings\u003c\/li\u003e\n\u003cli\u003eDate, time, and NTU reading can be captured with a serial printer or data recorder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"margin-left: auto; margin-right: auto;\" border=\"1px solid rgb(0, 0, 0)\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eNephelometric Non-ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eConformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eUSEPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eAuto Ranging from 0 - 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e± 2% of reading plus 0.01 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e0.01 NTU (0 - 9.99 NTU)0.1 NTU (10 - 99.9 NTU)1 NTU (100 - 1000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e≤ 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eSample Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e30 mL (27 mL minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eQuick Connect Tungsten Filament\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e32° - 122°F (0° - 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eRS-232 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e10.75 x 10 x 3.75 in. (27.3 x 25.4 x 9.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e2.9 lbs. (1.32 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eUL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete set of calibration standards (0.02, 10 and 1000 NTU)\u003c\/li\u003e\n\u003cli\u003eTwo measuring cuvettes with light shield caps\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003eOperator's manual\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111211827515,"sku":"92-2453-01-EA","price":1254.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2453-01.png?v=1784712023"},{"product_id":"oakton-model-t-100-waterproof-turbidity-meter-with-calibration-vials-cole-parmer-instrument-co-wd-35635-00","title":"Oakton Model T-100 Waterproof Turbidity Meter, with Calibration Vials, Cole Parmer Instrument Co.  WD-35635-00","description":"\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan id=\"ctl00_ctl00_ContentPlaceHolderMain_ContentPlaceHolderMainContent_lblSkuname\"\u003e\u003cspan class=\"blacktext\"\u003eCole-Parmer® Oakton®\u003c\/span\u003e\u003c\/span\u003e T-100 Turbidity Meter Kit, Handheld, Waterproof, with Standards, WD-35635-00\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e The OAKTON™ Model T-100 turbidity meter is easy to calibrate. It automatically prompts you to the next calibration standard.  This instrument was designed for portability and durability.  The microprocessor-based technology uses an infrared LED light source and delivers unprecedented repeatability and accuracy while offering resolutions as low as 0.01 NTU.  This lightweight meter is a valuable analytical tool for field-testing and quality control.  \u003cbr\u003e\u003cbr\u003eCalibration standards are provided in freeze-resistant 60 mL HDPE bottles for better shipping and longer shelf life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuto-ranging from 0 to 1000 NTU\u003c\/li\u003e\n\u003cli\u003eFour point push-button calibration for full-range accuracy\u003c\/li\u003e\n\u003cli\u003eWaterproof and dustproof with IP67 rated housing\u003c\/li\u003e\n\u003cli\u003eThe large custom LCD displays reading and units of measure\u003c\/li\u003e\n\u003cli\u003eIncludes auto-off, diagnostic error messages, and auto-ranging function\u003c\/li\u003e\n\u003cli\u003eSealed optical system with infrared light source delivers high accuracy across entire range\u003c\/li\u003e\n\u003cli\u003ePower saving function lets you take over 1000 readings on a single set of AAA batteries\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 year warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eApplications:\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChemical Industry\u003c\/li\u003e\n\u003cli\u003eFood Industry\u003c\/li\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSpecifications:\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTurbidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C \/ 32 to 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResolution, Turbidity    \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 NTU = 0.01 NTU\u003cbr\u003e20.0 to 99.9 NTU = 0.1 NTU\u003cbr\u003e100 to 1000 NTU = 1 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAccuracy, Turbidity\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 2% of measurement from 0 to 500 NTU\u003cbr\u003e± 3% of measurement from 501 to 1000 NTU  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eRepeatability, Turbidity   \u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01 NTU or ±1% of measurement, whichever is greater  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour AAA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eWaterproof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCE Compliant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeter:  2.7W x 6.1L x 1.8 H (6.8 x 15.5 x 4.6 cm)\u003cbr\u003eMeter w\/case:  6.3W x 13.8L x 4.7H (16 x 35 x 12 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeter: 7 oz (200g)\u003cbr\u003eMeter w\/case: 2.75 lbs (1.25 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003eSupplied with\u003c\/ul\u003e\n\u003cp\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 primary standards, 60 mL in HPTE bottles (0.02, 20.0, 100 and 800 NTU)\u003c\/li\u003e\n\u003cli\u003e4 labeled cuvettes for standards\u003c\/li\u003e\n\u003cli\u003e3 empty sample cuvettes\u003c\/li\u003e\n\u003cli\u003eLight shield cap\u003c\/li\u003e\n\u003cli\u003eSilicone oil, 10 mL\u003c\/li\u003e\n\u003cli\u003eLint-free cloth\u003c\/li\u003e\n\u003cli\u003e4 AAA batteries\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eInstructions Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Cole-Parmer","offers":[{"title":"EA (1)","offer_id":51111211991355,"sku":"92-2454-01-EA","price":1496.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2454-01.png?v=1784712028"},{"product_id":"model-t-100ir-portable-infrared-turbidity-meter-kit-oakton-35635-15","title":"Model T-100IR Portable Infrared Turbidity Meter Kit, Oakton, 35635-15","description":"\u003cp\u003e\u003cstrong\u003eCole-Parmer® Oakton® Model T-100IR Portable Infrared Turbidity Meter Kit, 35635-15\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuto-ranging from 0 to 1000 NTU (FNU)\u003c\/li\u003e\n\u003cli\u003eStores up to 500 sets of data\u003c\/li\u003e\n\u003cli\u003eSuitable for field use—meets IP67 water-resistant requirements\u003c\/li\u003e\n\u003cli\u003eInfrared light source delivers high accuracy across entire range\u003c\/li\u003e\n\u003cli\u003eMeets performance criteria as specified by ISO 7027 (DIN EN 27027) method\u003c\/li\u003e\n\u003cli\u003eIncludes normal and continuous measurement modes, parameter setup, data recall, real-time clock, calibration date check, automatic power off, and low voltage indication\u003c\/li\u003e\n\u003cli\u003eContinuous measure mode used to automatically generate average, maximum and minimum measured values in data storage interface, suitable for sample solutions with rapid settling and continuous measurement changes\u003c\/li\u003e\n\u003cli\u003eLarge TFT color screen displays blue background for measurement mode, green background for calibration mode, and features operation guides for easy calibration and measurement\u003c\/li\u003e\n\u003cli\u003eUSB interface cable can transfer this data to computer for future analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSix 25 x 60 mm sample test cuvettes\u003c\/li\u003e\n\u003cli\u003eFive 60-mL polymer standard calibration solutions (0.0, 20, 100, 400, and 800 NTU)\u003c\/li\u003e\n\u003cli\u003e10 mL of silicone oil\u003c\/li\u003e\n\u003cli\u003eMicrofiber wiping cloth\u003c\/li\u003e\n\u003cli\u003ePCLink software on USB flash drive\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eUSB cable with power adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Type\u003c\/td\u003e\n\u003ctd\u003ePortable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eTFT color screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01, 0.1, 1 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e≤±1 of reading or 0.02 NTU (FNU) (greater of the two)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e≤0.02 NTU (FNU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Size\u003c\/td\u003e\n\u003ctd\u003e500 sets of data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e20 hours continuous use; 40 days at 30-minute daily use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003eDistilled water or deionized water 0 NTU (FNU)\u003cbr\u003ePolymer or Formazin Solution 20 100 400 and 80 0 NTU (FNU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Record\u003c\/td\u003e\n\u003ctd\u003eCalibration date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eSilicon photovoltaic\u003cbr\u003eMeasuring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Modes\u003c\/td\u003e\n\u003ctd\u003eNormal measurement and continuous measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Vials\u003c\/td\u003e\n\u003ctd\u003e25 mm diameter ×60 mm length, high borosilicate glass with cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Cole-Parmer","offers":[{"title":"EA (1)","offer_id":51184689152315,"sku":"92-2454-11-EA","price":1695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2454-11_8538b399-a443-40e0-bf73-7003d9f1de8e.png?v=1784712033"},{"product_id":"microtpw-field-portable-turbidimeter-with-white-light-hf-scientific-20000","title":"MicroTPW Field Portable Turbidimeter with White Light, HF Scientific, 20000","description":"\u003cp\u003e\u003cstrong\u003eHF Scientific® MicroTPW Field Portable Turbidimeter with White Light, EPA Accepted, 20000\u003c\/strong\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAuto Ranging 0 to 1100NTU—self adjusts to the appropriate measurement\u003c\/li\u003e\n\u003cli\u003eRugged portable carrying case\u003c\/li\u003e\n\u003cli\u003eSimple calibration with the push of a button\u003c\/li\u003e\n\u003cli\u003eWaterproof housing allows measureing and cleaning in any environment\u003c\/li\u003e\n\u003cli\u003eSelf-contained case includes battery pack, manual, and calibration standards\u003c\/li\u003e\n\u003cli\u003eLong battery life—4-AAA batteries for over 5000 tests\u003c\/li\u003e\n\u003cli\u003eCalibration with ProCal standards makes calibration quick and easy\u003c\/li\u003e\n\u003cli\u003eMade in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"\" frame=\"\" rules=\"\" align=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSEPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto Ranging from 0 to 1100 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 NTU \u0026lt; 100 NTU0.1 NTU — 100 to 999.9 NTU1 NTU — 1000 to 1100 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 2% of reading or ± 0.01 NTU — 0 to 500 NTU± 3% of reading — 500 to 1100 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 - AAA alkaline batteries (over 5000 tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 digit — 7-segment LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrinciple of Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNephelometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, NEMA 4X, Designed to meet IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite light—Tungsten\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eProCal calibration standards\u003c\/li\u003e\n\u003cli\u003eIndexing rings\u003c\/li\u003e\n\u003cli\u003e4-AAA alkaline batteries\u003c\/li\u003e\n\u003cli\u003e2-Measuring cuvettes with light shield caps\u003c\/li\u003e\n\u003cli\u003eLens cloth\u003c\/li\u003e\n\u003cli\u003eInstruction manual and card\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111212450107,"sku":"92-2456-01-EA","price":2007.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2456-01_9249ec3c-37c5-4f9e-9a25-93d1a95351a6.png?v=1784712054"},{"product_id":"2100q-portable-turbidimeter-epa-0-1000-ntu-hach","title":"2100Q Portable Turbidimeter (EPA), 0-1000 NTU, HACH","description":"\u003cp\u003e\u003cstrong\u003eHACH® 2100Q Portable Turbidimeter (EPA), 0-1000 NTU, \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTungsten filament lamp\u003c\/li\u003e\n\u003cli\u003eEasiest calibration and verification with accurate results every time\u003c\/li\u003e\n\u003cli\u003eMeasuring and monitoring turbidity is crucial for various industrial and municipal applications\u003c\/li\u003e\n\u003cli\u003e2100Q Portable Turbidimeter provides unsurpassed ease of use and accuracy\u003c\/li\u003e\n\u003cli\u003eHach is a leader in turbidity measurement and has consistently developed reliable and durable instruments for customers.\u003c\/li\u003e\n\u003cli\u003eIdeal for use in field or around plant —easy to carry around and take multiple measurements from various collection points in treatment process\u003c\/li\u003e\n\u003cli\u003eWith its intuitive user interface, it easy to take measurements, perform calibration and verification, storing and transferring data\u003c\/li\u003e\n\u003cli\u003eOptional USB+Power module for the 2100Q Portable Turbidimeter, which allows transfer of data directly to computer\u003c\/li\u003e\n\u003cli\u003eCompliant with USEPA Method 180.1 design criteria\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2100Q Instrument\u003c\/li\u003e\n\u003cli\u003eCase assembly\u003c\/li\u003e\n\u003cli\u003e4 AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003e6 sample cells\u003c\/li\u003e\n\u003cli\u003eStablcal® ampule kit\u003c\/li\u003e\n\u003cli\u003eSilicone oil\u003c\/li\u003e\n\u003cli\u003eOiling cloth\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e500 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e240 x 160 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eNo USB and Power Cord\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eTungsten Filament Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Languages\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eRatio turbidimetric determination using a primary nephelometric light scatter signal (90°) and transmitted light scatter signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003eNormal (Push to Read), Signal Averaging, Rapidly Settling Turbidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBatteries (see Battery Requirements) or Optional Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eNormal (Push to Read)\u003cbr\u003eSignal Averaging\u003cbr\u003eRapidly Setting Turbidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory\u003c\/td\u003e\n\u003ctd\u003eEPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e± 1 % of reading or 0.01 NTU , whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e6 s in normal reading mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cell Compatibility\u003c\/td\u003e\n\u003ctd\u003e25 mm x 60 mm round\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e15 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Averaging\u003c\/td\u003e\n\u003ctd\u003eSelectable on\/off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Lamp\u003c\/td\u003e\n\u003ctd\u003eTungsten filament lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.02 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eNTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eButton Graphic User Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface Languages\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Spanish, Portuguese (BR), Portuguese (PT), Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111212482875,"sku":"92-2456-02-EA","price":2149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2456-02_e7ffd371-1e3d-4c8b-8085-483c4b8a9915.png?v=1784712057"},{"product_id":"tl2350-tungsten-lamp-turbidimeter-epa-approved-0-to-10000-ntu-hach-lpv444-99-00310","title":"TL2350 Tungsten Lamp Turbidimeter, EPA Approved, 0 to 10000 NTU, HACH, LPV444.99.00310","description":"\u003cp\u003e\u003cstrong\u003eHACH® TL2350 Tungsten Lamp Turbidimeter, EPA Approved, 0 to 10000 NTU, LPV444.99.00310\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge full color touch screen display and intuitive user interface accelerate setup, calibration and measurement\u003c\/li\u003e\n\u003cli\u003eEasy interface and guided procedures give reliable results\u003c\/li\u003e\n\u003cli\u003eUSB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance —  Hach\u003csup\u003e®\u003c\/sup\u003e makes it easy to Be Right\u003c\/li\u003e\n\u003cli\u003eEnsures stable readings and accurate analysis by capturing turbidity readings once device detects sample stability — quality step removes subjectivity and  need for repeated measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL2350 Turbidimeter\u003c\/li\u003e\n\u003cli\u003eSilicone oil\u003c\/li\u003e\n\u003cli\u003eOiling cloth\u003c\/li\u003e\n\u003cli\u003eUSEPA filter assembly\u003c\/li\u003e\n\u003cli\u003e1-inch sample cells (30 mL) with caps (6x)\u003c\/li\u003e\n\u003cli\u003eGelex secondary turbidity standardization kit\u003c\/li\u003e\n\u003cli\u003eStablcal calibration kit\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRatio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU ±10 % of reading from 4000 - 10000 NTU\u003c\/p\u003e\n\u003cp\u003eRatio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy 3\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAbsorbance: ±0.01 Abs from 0 - 0.5 Abs at 455 nm, ±2% Abs from 0.5 - 1 Abs at 455 nm\u003c\/p\u003e\n\u003cp\u003eTransmittance: 2% T from 10 - 100% T at 455 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Purge\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDry nitrogen or instrument grade air (ANSI MC 11.1, 1975)\u003c\/p\u003e\n\u003cp\u003e0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max\u003c\/p\u003e\n\u003cp\u003eHose barb connection for 1\/8-inch tubing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e2000 total logs, includes reading log, verification log and calibration log\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e17.8 mm (7 in.) color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eTungsten filament lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eNephelometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTL2350 EPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eSingle, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory\u003c\/td\u003e\n\u003ctd\u003eMeets EPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eSignal averaging off: 6.8 seconds \/ Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cell Compatibility\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRound cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Requirements\u003c\/td\u003e\n\u003ctd\u003e25 mm sample cell: 20 mL minimum\u003cbr\u003e0 to 70 °C (32 to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Lamp\u003c\/td\u003e\n\u003ctd\u003eTungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRatio on: 30 minutes after start-up\u003c\/p\u003e\n\u003cp\u003eRatio off: 60 minutes after start-up\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eNTU, EBC, Abs (absorbance), %T (% transmittance) and mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111212548411,"sku":"92-2456-03-EA","price":6814.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2456-03.png?v=1784712058"},{"product_id":"micro-100-laboratory-turbidimeter-0-1000-ntu-120-v-60-hz-hf-scientific-20001","title":"Micro 100 Laboratory Turbidimeter, 0 - 1000 NTU, 120 V 60 Hz, HF Scientific, 20001","description":"\u003cp\u003e\u003cstrong\u003eHF Scientific® Micro100 Laboratory Turbidimeter, 120 VAC, 60 Hz, 20001\u003c\/strong\u003eThe Micro 100 Lab Turbidimeter is an ideal and affordable tool for research as well as routine analytical measurements. It is designed to provide the accuracy demanded by today's scientist and is ready to meet the challenge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstrument senses turbidity level of sample and automatically adjusts to the appropriate measurement\u003c\/li\u003e\n\u003cli\u003eAutomatically prompts the operator when calibration of the instrument is needed\u003c\/li\u003e\n\u003cli\u003eCalibration initiated with the push of a button ensures accurate readings\u003c\/li\u003e\n\u003cli\u003eDate, time, and NTU reading can be captured with a serial printer or data recorder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"margin-left: auto; margin-right: auto;\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eMeasurement Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eNephelometric Non-ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eConformance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eUSEPA Method 180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eAuto Ranging from 0 - 1000 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e± 2% of reading plus 0.01 NTU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e0.01 NTU (0 - 9.99 NTU)0.1 NTU (10 - 99.9 NTU)1 NTU (100 - 1000 NTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e≤ 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eSample Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e30 mL (27 mL minimum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eQuick Connect Tungsten Filament\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e32° - 122°F (0° - 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eRS-232 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e10.75 x 10 x 3.75 in. (27.3 x 25.4 x 9.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e2.9 lbs. (1.32 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003eUL, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete set of calibration standards (0.02, 10 and 1000 NTU)\u003c\/li\u003e\n\u003cli\u003eTwo measuring cuvettes with light shield caps\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003eOperator's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cspan\u003e \u003cbr\u003e\u003c\/span\u003e\u003c\/div\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111584071995,"sku":"HFS-20001-EA","price":1240.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/HFS-20001_acb5be1f-6ede-484a-a77a-7b8512721d15.png?v=1784719651"},{"product_id":"turbidimeter-m100-laboratory-white-light-tungsten-filament-hf-scientific-28060","title":"Turbidimeter, M100+ Laboratory, White Light (Tungsten Filament), HF Scientific, 28060","description":"\u003cp\u003e\u003cstrong\u003eHF Scientific® Turbidimeter, M100+ Laboratory, White Light (Tungsten Filament), 28060\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAuto Ranging from 0 to 4000 NTU Instrument senses turbidity level of sample and automatically adjusts measurement range\u003c\/li\u003e\n\u003cli\u003eCalibration alert prompts operator when calibration is required\u003c\/li\u003e\n\u003cli\u003eSimple calibration procedure - insert calibration standard and initiate calibration with press of button\u003c\/li\u003e\n\u003cli\u003eData logging - download historical NTU readings through USB connection or send to printer or data recorder\u003c\/li\u003e\n\u003cli\u003eWhite light model is EPA 180.1 compliant (Also available is ISO 7027 infrared model)\u003c\/li\u003e\n\u003cli\u003eReusable ProCal Calibration Standards offer quick, easy calibration across all ranges without need to mix Formazin\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProCal Calibration Kit for the full 0–4000 NTU range (standards), 39940 \u003c\/li\u003e\n\u003cli\u003eTwo measuring cuvettes with light-shield caps\u003c\/li\u003e\n\u003cli\u003ePower adapter\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111211860283,"sku":"92-2453-02-EA","price":2890.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2453-02.png?v=1784712025"},{"product_id":"turbidimeter-model-tl2300-tungsten-lamp-epa-approved-0-to-4000-ntu-hach-lpv444-99-00210","title":"Turbidimeter, Model TL2300, Tungsten Lamp, EPA Approved, 0 to 4000 NTU, HACH, LPV444.99.00210","description":"\u003cp\u003e\u003cstrong\u003eHACH® Turbidimeter, Model TL2300, Tungsten Lamp, EPA Approved, 0 to 4000 NTU, LPV444.99.002\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAchieve precise turbidity measurements across wide range of water qualities fro 0 to 4000 NTU while ensuring it meets EPA Method 180.1\u003c\/li\u003e\n\u003cli\u003eDesigned for simplicity, accuracy, and reliability\u003c\/li\u003e\n\u003cli\u003eEquipped with tungsten lamp\u003c\/li\u003e\n\u003cli\u003eReduce errors and eliminate uncertainty with automatic sample stability detector for acurate turbidity measurements\u003c\/li\u003e\n\u003cli\u003eIntuitive color touchscreen and clear, step-by-step instructions allows every user to follow best practices and achieve consistent measurements\u003c\/li\u003e\n\u003cli\u003eReduce downtime and improve efficiency with quick USB data export and proactive self-diagnostics\u003c\/li\u003e\n\u003cli\u003eReading modes: Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off \u003c\/li\u003e\n\u003cli\u003eUnits: NTU and EBC\u003c\/li\u003e\n\u003cli\u003eMeasurement method: Nephelometric\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSilicone oil\u003c\/li\u003e\n\u003cli\u003eOiling cloth\u003c\/li\u003e\n\u003cli\u003eUSEPA filter assembly\u003c\/li\u003e\n\u003cli\u003e1-inch sample cells (30 mL) with caps (6x)\u003c\/li\u003e\n\u003cli\u003eGelex secondary turbidity standardization kit\u003c\/li\u003e\n\u003cli\u003eStablcal calibration kit\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003cli\u003ePower cord\u003c\/li\u003e\n\u003cli\u003eDust cover\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111212646715,"sku":"92-2456-04-EA","price":4273.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2456-04.png?v=1784712059"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/collections\/imgi_4_70709.jpg?v=1762201847","url":"https:\/\/preiser.com\/collections\/turbidity-meter.oembed","provider":"Preiser Scientific","version":"1.0","type":"link"}