{"product_id":"barnstead-genpure-xcad-plus-uv-uf-toc-water-purification-system-wall-version-thermo-scientific-50136172","title":"Barnstead GenPure xCAD Plus UV\/UF - TOC Water Purification System (Wall Version), Thermo Scientific 50136172","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Barnstead™ GenPure™ xCAD Plus UV\/UF - TOC (wall version), Type 1 Water System, 50136172\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003exCAD (Extended Control and Dispenser):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSystem provides more flexibility for ultrapure water dispensing with an action radius of 32 in. (80 cm)\u003c\/li\u003e\n\u003cli\u003eErgonomic dispensing arm provides precise volume dosing at the press of a button\u003c\/li\u003e\n\u003cli\u003eFlexible dispenser offers positions including turned, height adjusted or extended toward your vessel\u003c\/li\u003e\n\u003cli\u003eOne-of-a-kind design provides access to all system controls at your fingertips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSimultaneously dispense from up to three dispensers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEach system ships with single xCAD Plus remote dispenser\u003c\/li\u003e\n\u003cli\u003eFor increased flexibility, add one or two more xCAD Plus dispensers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntegrated feed water monitoring:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional measuring cell monitors feed water conductivity\u003c\/li\u003e\n\u003cli\u003eIf quality of feed water drops below the set value, fault message will immediately be displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnline TOC measurement with UV intensity monitoring (available on systems with optional TOC only):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time TOC monitoring offers continual measurement of organic substances present in water\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of UV intensity removes risk of false TOC values due to diminished UV intensity\u003c\/li\u003e\n\u003cli\u003eFault message alerts user when UV lamp intensity is no longer sufficient for accurate TOC measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUV Photo-oxidation 185\/254 nm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh performance UV assembly reliably reduces content of microorganisms and their metabolites\u003c\/li\u003e\n\u003cli\u003eUV oxidation also reduces organic compounds in water to ultra-low levels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLeak detection:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn error message is displayed when internal leaks are detected\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReady to use:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile filter, all are included in one part number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMeasurement of conductivity\/resistivity:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature measurements are made by a platinum chip sensor with ± 0.1 °C accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eQuick-connect cartridge replacement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAquastop quick-connect capability enables cartridge replacement within seconds even mid-operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExact dosing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectronic dosing yields fully automatic volume control of 0.01-65 L with \u0026lt;2% accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGLP-compliant documentation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time clock and code-protected operating system prevents unauthorized changes to system settings\u003c\/li\u003e\n\u003cli\u003eRS-232 interface with adjustable send-interval offers safe data transfer of all measured data, faults, date and time to a PC computer or log printer\u003c\/li\u003e\n\u003cli\u003eDigital microprocessor control automatically monitors and stores faults from the last four weeks\u003c\/li\u003e\n\u003cli\u003eUSP-compliant conductivity measurement with temperature compensation can be switched on or off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eBarnstead GenPure xCAD Plus UV\/UF – TOC (wall version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacterial Content\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.01 CFU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndotoxin Concentration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.001 EU\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedwater Connector\u003c\/td\u003e\n\u003ctd\u003e3\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed Water Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Water Type\u003c\/td\u003e\n\u003ctd\u003eType 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Dispenser\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTOC Monitor with UV Intensity Monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eWater Purification System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eBarnstead GenPure xCAD Plus UV\/UF - TOC (wall version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd\u003e0.1 to 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticles \u0026gt;0.2µM\/mL\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111223492923,"sku":"92-2747-08-EA","price":17200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2747-08_caa15e55-bb02-4332-92bc-9df8cdd71e07.png?v=1784712375","url":"https:\/\/preiser.com\/products\/barnstead-genpure-xcad-plus-uv-uf-toc-water-purification-system-wall-version-thermo-scientific-50136172","provider":"Preiser Scientific","version":"1.0","type":"link"}