{"product_id":"barnstead-genpure-xcad-plus-uv-uf-water-purification-system-bench-version-thermo-scientific-50136151","title":"Barnstead GenPure xCAD Plus UV\/UF Water Purification System (Bench Version), Thermo Scientific 50136151","description":" \u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eAll GenPure™ systems exceed international standards ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW  \u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e  \u003cstrong\u003exCAD (Extended Control and Dispenser):\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eSystem proves more flexibility for ultrapure water dispensing with an action radius of 32\" (80 cm)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eErgonomic dispensing arm provides precise volume dosing at the press of a button\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eFlexible dispenser offers positions including turned, height adjusted or extended toward you vessel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eOne-of-a-kind design provides access to all system controls at your fingertips.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Simultaneously dispense from up to three dispensers:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eEach system ships with a single xCAD Plus remote dispenser\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eFor increased flexibility, add one or two more xCAD Plus dispensers\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Integrated feed water monitoring:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eAdditional measuring cell monitors feed water conductivity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eIf the quality of the feed water drops below the set value, a fault message will immediately be displayed\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Online TOC measurement with UV intensity monitoring (available on systems with optional TOC only):\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eReal-time TOC monitoring offers continual measurement of organic substances present in the water\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eContinuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eFault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e \u003cstrong\u003eUV Photo-oxidation 185\/254 nm:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eHigh performance UV assembly reliably reduces the content of microorganisms and their metabolites\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eUV oxidation also reduces organic compounds in the water to ultra-low levels\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e \u003cstrong\u003eLeak detection:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eAn error message is displayed when internal leaks are detected\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Ready to use:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eFeed water pressure switch, wall bracket, UV lamp, ultrapure cartridge sterile filter, all are included in one part number\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Measurement of conductivity\/resistivity:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eConductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01 cm¯¹\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eTemperature measurements are made by a platinum chip sensor with ±0.1ºC accuracy\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Quick-connect cartridge replacement:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eAquastop quick-connect capability enables cartridge replacement within seconds even mid-operation\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003e Exact dosing:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eElectronic dosing yields fully automatic volume control of 0.01-65 L with \u0026lt;2% accuracy.\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003c\/span\u003e\u003cdiv style=\"margin-top: 0.5em;\"\u003e\n\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cstrong\u003eGLP-compliant documentation:\u003c\/strong\u003e \u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eReal-time clock and code-protected operating system prevents unauthorized changes to system settings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eRS-232 interface with adjustable send-interval for safe data transfer of all measured data, faults, date and time to a PC computer or log printer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eDigital microprocessor control automatically monitors and stores faults from the last four weeks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eUSP-compliant conductivity measurement with temperature compensation can be switched on or off\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e  \u003c\/span\u003e\u003ctable style=\"border-collapse: collapse; width: 506px; height: 309px;\" align=\"left\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt; color: #444444; font-family: Times New Roman;\"\u003e\u003c\/span\u003eFlow Rate, min. \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt; color: #444444; font-family: Times New Roman;\"\u003e\u003c\/span\u003eUp to 2 L\/min. \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr startcont=\"this\"\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eOperating Pressure min. and max \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e0.1 to 6 bars \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-size: 10pt; font-family: Times New Roman;\"\u003eTotal Organic Carbon \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-size: 10pt; font-family: Times New Roman;\"\u003e1 to 5 ppb \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eBacterial content \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u0026lt;0.01 CFU\/mL \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eParticles \u0026gt; 0.2µm\/mL \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u0026lt; 1 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-size: 10pt; font-family: Times New Roman;\"\u003eFeed Water Monitoring \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-size: 10pt; font-family: Times New Roman;\"\u003eIntegrated \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt; color: #444444; font-family: Times New Roman;\"\u003e\u003c\/span\u003eFeed Water Connector \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-size: 10pt; color: #444444; font-family: Times New Roman;\"\u003e\u003c\/span\u003e3\/4 in. NPT \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eDimensions (D x W x H) \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: #000000 1px solid;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e13 x 14.6 x 24 in. (330 x 372 x 615 mm) \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\" colspan=\"1\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eConductivity \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\" colspan=\"1\"\u003e\n\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e0.055µ\u003c\/span\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eS\/cm \u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: #000000; background-color: #c3dffc; border-style: solid; border-width: 1px;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003eResistance @ 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #000000;\"\u003e\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e18.2MΩ-cm\u003c\/span\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111223329083,"sku":"92-2747-05-EA","price":16300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2747-05.png?v=1784712371","url":"https:\/\/preiser.com\/products\/barnstead-genpure-xcad-plus-uv-uf-water-purification-system-bench-version-thermo-scientific-50136151","provider":"Preiser Scientific","version":"1.0","type":"link"}