{"product_id":"carbon-sulfur-analyzer-helios-cs-580a-2-cell-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4018-shown-with-sample-autoloader-attached","title":"Eltra Carbon\/Sulfur Analyzer - Helios, CS-580A 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance, Verder Scientific,  88100-4018 (Shown with Sample Autoloader Attached)","description":"\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eModel # 88100-4018\u003c\/strong\u003e Eltra Carbon \/ Sulfur Analyzer \"Helios\" CS-580A 2 Cell 2xS 0.005-2% S + 2-20% S - Includes Analyzer, Computer, and Balance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Eltra CS-580A Analyzer offers the ideal in simultaneous determination of carbon and sulfur for organic samples.  All CS-580A seriers analyzers come equipped with an automatic sample loader.  Loaders come in two size options to accommodate 36 or 130 crucibles to meet user demand.  This unit is based on the same technology as the CS-580 but features a vertical resistance furnace with ceramic tube.  The temperature can be set in steps of 1 ºC to a maximum of 1550 ºC. Because of sample weights of up to 500 mg and more, this analyzer can reliably analyze even inhomogenous materials.  The analyzer has the capability of accommadating up to four independent infrared cells to allow for use in a variety of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePossible Applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAshes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eLimestone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoils\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBuilding Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eOil\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSoot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003ePlant Materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eTobacco\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eCoke\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eRubber\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eWaste\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eGypsum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eSand\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eand Others\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous carbon and sulfur determination with minimal sample preparation\u003c\/li\u003e\n\u003cli\u003eWide range of organic materials can be analyzed\u003c\/li\u003e\n\u003cli\u003eRapid, precise, accurate and reliable element determination\u003c\/li\u003e\n\u003cli\u003eResistance furnace can be set up to 1550 ºC in steps of 1 ºC\u003c\/li\u003e\n\u003cli\u003eCustomized infrared cells provide wide, dynamic measuring range\u003c\/li\u003e\n\u003cli\u003eDue to gold IR path, increased cell life time for analysis of halogen or acid containing samples\u003c\/li\u003e\n\u003cli\u003ePowerful software (multilingual, customized display, export of results)\u003c\/li\u003e\n\u003cli\u003eSingle and multipoint calibration\u003c\/li\u003e\n\u003cli\u003eLow maintenance\u003c\/li\u003e\n\u003cli\u003eRobust design allows usage in production control and laboratory\u003c\/li\u003e\n\u003cli\u003eFor sulfur coal analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFunction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation \u003c\/strong\u003eThe samples are weighed into crucibles. Then a gripper places the samples from the Autoloader on the pedestal.  The samples are loaded consecutively into the furnace for combustion.  The average analysis time is 60 to 120 seconds.  Detector signals and instrument parameters are displayed during analysis.  Evaluation of the signals and display of the results are done automatically; data can be transferred to a laboratory information management system (LIMS).  The analyzers require minimal maintenance.  Particle filters and chemicals needed are easily accessible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasuring \u003c\/strong\u003eThe sample is burnt in an oxygen atmosphere at temperatures of up to 1550 ºC.  Furnace temperature can be freely selected in 1 ºC steps.  The combustion gases (CO\u003csub\u003e2\u003c\/sub\u003e, H\u003csub\u003e2\u003c\/sub\u003eO, SO\u003csub\u003e2\u003c\/sub\u003e) coming from the furnace pass through a dust filter.  After the water vapor is chemically absorbed, the dried CO\u003csub\u003e2\u003c\/sub\u003e and SO\u003csub\u003e2\u003c\/sub\u003e gas is detected in the additional infrared cells.  Depending on the configuration, it is possible to combine up to four infrared cells with different sensitivities.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasure elements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCarbon, sulfur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrganic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace Allignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Carrier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCeramic crucibles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField of Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgriculture, biology, chemistry\/plastics, coal\/power plant, construction materials, environment\/recycling, medicine\/pharmaceuticals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFurnace\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance furnace (ceramic tube) adjustable up to 1550 ºC (steps of 1 ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolid state infrared absorption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of IR Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of IR Path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Analysis Time  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60-120 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemicals Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnesium perchlorate, sodium hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eoxygen 99.5 % pure (2 - 4 bar \/ 30 - 60 psi) compressed air (4 - 6 bar \/ 60 - 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V, 50\/60 Hz, max. heat up current 2000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55 x 100 x 60 cm (analyzer); 85 x 35 x 45 cm (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~90 kg (analyzer); ~15kg (Autoloader for 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequried Equipment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalance (resolution 0.0001g), monitor, PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRequired Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutoloader (for 36 or 130 crucibles)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTIC module, voltage stabilizer 5 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eOther Models Available\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable border=\"1\" frame=\"border\" rules=\"all\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreiser Part No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMfg. Model No. \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-01\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4015\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xC 0.05-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-02\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4016\u003c\/td\u003e\n\u003ctd\u003eCS-580A 1 Cell 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-03\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4017\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xC 0.005-12% C | 12-100% C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-04\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4018\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-05\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4019\u003c\/td\u003e\n\u003ctd\u003eCS-580A 2 Cell 1xC 0.05-100% C + 1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-06\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4020\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 1xC 0.05-100% C + 2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-07\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4021\u003c\/td\u003e\n\u003ctd\u003eCS-580A 3 Cell 2xC 0.005-12% C | 12-100% C +1xS 0.005-2% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e92-1204-08\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e88100-4022\u003c\/td\u003e\n\u003ctd\u003eCS-580A 4 Cell 2xC 0.005-12% C | 12-100% C +2xS 0.005-2% S | 2-20% S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Verder Scientific","offers":[{"title":"EA (1)","offer_id":51111148585275,"sku":"92-1204-04-EA","price":35450.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1204-04.png?v=1784710673","url":"https:\/\/preiser.com\/products\/carbon-sulfur-analyzer-helios-cs-580a-2-cell-2xs-0-005-2-s-2-20-s-includes-analyzer-computer-and-balance-eltra-88100-4018-shown-with-sample-autoloader-attached","provider":"Preiser Scientific","version":"1.0","type":"link"}