{"product_id":"detonation-calorimeter-parr-instrument-company-6790","title":"Detonation Calorimeter, Parr Instrument Company, 6790","description":"\u003cp\u003e\u003cstrong\u003eParr Instrument Company® Detonation Calorimeter, Model 6790\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrdinary oxygen bomb combustion calorimetry\u003c\/strong\u003e is used to measure the heat of combustion or reaction of materials in oxygen or inert atmospheres. Even for high strength vessels, such as the Parr 1104 Oxygen Combustion Bomb, the conditions necessary to detonate small amounts of highly reactive materials are often difficult to achieve and can result in unpredictable consequences. For example, the conventional heat of combustion of pentaerythritol tetranitrate (PETN) [C\u003csub\u003e5\u003c\/sub\u003eH\u003csub\u003e8\u003c\/sub\u003eN\u003csub\u003e4\u003c\/sub\u003eO\u003csub\u003e12\u003c\/sub\u003e] in oxygen is 1957 cal\/g while the heat of detonation in vacuum is 1490 cal\/g (a 24% difference).\u003c\/p\u003e\u003cp\u003eAdditionally, it is well known that the degree of confinement of explosive materials significantly influences the released energy. For unconfined or lightly confined charges, the released energy is largely retained in the products. When the charge is heavily confined, the detonation energy, for the most part, is converted to kinetic and internal energy of the confining case. For example, the conventional heat of combustion of 2,4,6-trinitrotoluene (TNT) in oxygen is 3590 cal\/g. The heat of detonation for TNT at a charge density of 1.53 g\/cc is 1093 cal\/g and at a charge density of 0.998 g\/cc is 870 cal\/g. In contrast, an unconfined reaction yields approximately 600 cal\/g.\u003c\/p\u003e\u003cp\u003ePrecise fundamental information about the detonation process can be obtained by combining calorimetric and dynamic pressure measurements. These measurements can be used ultimately to predict explosives performance. The Parr Detonation Calorimeter has been designed to aid research in this area. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDetonation calorimeter accepts up to 25 g high explosive charge with nominal total energy release per charge of ~160kJ\u003c\/li\u003e\n\u003cli\u003eDetonation is achieved using small commerical EBW style detonator incorporating 80 mg of PETN and 450 mg of RDX with binder\u003c\/li\u003e\n\u003cli\u003eFiring is initiated using one-microfarad - 4000 V capacitance discharge firing set\u003c\/li\u003e\n\u003cli\u003eComplete calorimetric measurement can be made over few hours with precision of several tenths of percent\u003c\/li\u003e\n\u003cli\u003eDigital calorimetric thermometer is available separately to use with Parr calorimeters\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eBomb:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBomb can be optionally fitted with high-speed pressure transducer that allows user to gain further insight into dynamics of detonation process\u003c\/li\u003e\n\u003cli\u003eDistinctive spherical bomb is made of 3.2 cm thick stainless steel with inside diameter of 21.6 cm providing internal volume of 5.3 liters\u003c\/li\u003e\n\u003cli\u003e9 cm opening is covered by lid 3.8 cm thick at center\u003c\/li\u003e\n\u003cli\u003eLid is secured by 12 x 1.3 cm diameter, high strength bolts inserted through lid flange and sealed with o-ring\u003c\/li\u003e\n\u003cli\u003eLid incorporates bomb lift fitting at center, surrounded by inlet \/ outlet valve and two high-voltage style insulated electrodes\u003c\/li\u003e\n\u003cli\u003eOptional port can be provided on lid for fast responding pressure transducer\u003c\/li\u003e\n\u003cli\u003eMass of the bomb (cylinder and lid) is 55 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCalorimeter Stand:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDetonation calorimeter uses classic design incorporating compensated static jacket which has been used successfully for many years in two generations of Parr calorimeters (Models 1356 \u0026amp; 6100)\u003c\/li\u003e\n\u003cli\u003eCalorimeter stand houses calorimeter jacket and also includes bomb lift hoist as well as conveniently placed bomb support and bomb head stand\u003c\/li\u003e\n\u003cli\u003eCalorimeter lid is stored on lower shelf, below bomb workstation, when not in use\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parr Instrument Company","offers":[{"title":"EA (1)","offer_id":51110876315963,"sku":"90-4056-01-EA","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-4056-01.png?v=1784703221","url":"https:\/\/preiser.com\/products\/detonation-calorimeter-parr-instrument-company-6790","provider":"Preiser Scientific","version":"1.0","type":"link"}