{"product_id":"digi-sense-type-t-kapton-insulated-thermocouple-probe-miniconnector-6-pk-cole-parmer-instrument-company-wd-08505-85","title":"Digi-Sense Type T Kapton-Insulated Thermocouple Probe, Miniconnector, 6\/PK, Cole-Parmer Instrument Company, WD-08505-85","description":"\u003cspan style=\"color: #000000; font-family: Verdana; font-size: 13px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 16px; orphans: auto; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: auto; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none;\"\u003e\u003cspan style=\"color: #000000; font-family: Verdana; font-size: 13px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 16px; orphans: auto; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: auto; word-spacing: 0px; -webkit-text-stroke-width: 0px; display: inline !important; float: none;\"\u003e\u003cspan style=\"font-family: Times New Roman; font-size: 10pt;\"\u003e\u003cspan style=\"font-family: arial, helvetica, sans-serif; font-size: small;\"\u003e\u003cspan id=\"ctl00_ctl00_ContentPlaceHolderMain_ContentPlaceHolderMainContent_LblMarketingtext\" itemprop=\"description\" style=\"color: #000000; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 16px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; word-spacing: 0px;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cspan id=\"ctl00_ctl00_ContentPlaceHolderMain_ContentPlaceHolderMainContent_LblMarketingtext\" itemprop=\"description\" style=\"color: #000000; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 16px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; widows: 1; word-spacing: 0px;\"\u003e\u003cspan style=\"font-size: small; font-family: arial, helvetica, sans-serif;\"\u003e\u003cstrong\u003eCole-Parmer® Digi-Sense® Type-T, Kapton-Insultated Probe, Mini-Connector, Exposed Tip, 5 ft., 30-Gauge, 6\/PK, WD-08505-85Features:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eFlexible Kapton-insulated probe has fast response time of 0.35 seconds or greater making it ideal for checking food temperatures\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eStraight insulated cable with no handle\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eANSI color-coded blue mini connector for Type-T probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size: small;\"\u003eExposed junction not recommended for use with aqueous solutions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable frame=\"border\" rules=\"all\" style=\"border-color: #000000; border-width: 1px;\" border=\"1\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e-200 to 260 °C (-328 to 500 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature Accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAbove 100 °C (212 °F): ± 1.1 °C (±3 °F) or ±0.4% reading;Between -50 to 99 °C (-58 to 211 °F):  ±2.2 °C (±3.6 °F) or ±2% of reading;Between -51 to -150 °C (-60 to -238 °F):  ±4 °C (±7.2 °F) or ±4% of reading\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eJunction Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eExposed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eConnector Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMini-Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSheath Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eKapton-insulated wire\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSheath Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e60 in.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSheath Diameter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.01 in.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCable Wire Gauge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eProbe Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eType-T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e","brand":"Cole-Parmer","offers":[{"title":"PK (1)","offer_id":51111030260027,"sku":"91-2612-20-PK","price":171.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2612-20_79e53d99-90bc-4d7d-abeb-b31b0bd52dbe.png?v=1784707234","url":"https:\/\/preiser.com\/products\/digi-sense-type-t-kapton-insulated-thermocouple-probe-miniconnector-6-pk-cole-parmer-instrument-company-wd-08505-85","provider":"Preiser Scientific","version":"1.0","type":"link"}