{"product_id":"dr6000-uv-vis-spectrophotometer-without-rfid-100-240-v-hach-lpv441-99-00002","title":"DR6000 UV VIS Spectrophotometer without RFID, 100 - 240 V, HACH, LPV441.99.00002","description":"\u003cp\u003e\u003cstrong\u003eHACH® DR6000 UV VIS Spectrophotometer without RFID, 100 - 240 V, HACH, LPV441.99.00002\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry's most advanced laboratory spectrophotometer for water testing\u003c\/li\u003e\n\u003cli\u003eHigh-speed wavelength scanning across the UV and Visible Spectrum\u003c\/li\u003e\n\u003cli\u003eOver 250 pre-programmed methods which include most common water and environmental testing methods\u003c\/li\u003e\n\u003cli\u003eOptional accessories allowfor high-volume testing via carousel sample changer, and increased accuracy with sample delivery system that eliminates optical difference errors\u003c\/li\u003e\n\u003cli\u003eAdditional accuracy can be attained by using HACH's patented TNTplus™ test kits\u003c\/li\u003e\n\u003cli\u003eMakes scratched, flawed or dirty glassware a non-issue due to averaging 10 readings and discarding outliers\u003c\/li\u003e\n\u003cli\u003eRFID technology automatically alerts user when TNTplus test kits have expired, while detecting coefficient factors to avoid errors which can occur in lot-to-lot variations in the chemistries\u003c\/li\u003e\n\u003cli\u003eIntegrated quality assurance software package allows for scheduling, documenting and interpreting required quality measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1x DR6000 UV VIS Spectrophotometer\u003c\/li\u003e\n\u003cli\u003e1x Power Cord (US, EU)\u003c\/li\u003e\n\u003cli\u003e1x Universal-Adapter\u003c\/li\u003e\n\u003cli\u003e1x Dust Cover\u003c\/li\u003e\n\u003cli\u003eMatched pair of 1 inch glass sample cells\u003c\/li\u003e\n\u003cli\u003ePrinted multilingual basic user manual (en, fr, es, pt, zh, jp, ko)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logger\u003c\/td\u003e\n\u003ctd\u003e5000 data points (result, date, time, sample-ID, user-ID)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eTFT 7 inch WVGA color touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Languages\u003c\/td\u003e\n\u003ctd\u003een, es, fr, ja, ko, pt, zh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eTransmittance (%), absorbance and concentration (wavelength, time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eReference beam, spectral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric Linearity\u003c\/td\u003e\n\u003ctd\u003e0.005 - 2 Abs\u003cbr\u003e≤ 0.01 at \u0026gt; 2 Abs with neutral glass at 546 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreprogrammed Methods\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cell Compatibility\u003c\/td\u003e\n\u003ctd\u003eRectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch, Optional 100 mm rectangular cell with additional adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource Lamp\u003c\/td\u003e\n\u003ctd\u003eTungsten (visible range), deuterium (UV range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Technology\u003c\/td\u003e\n\u003ctd\u003eRFID for easy method update, sample ID and Certificate of Analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd\u003e2 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 °C \/ max. 80% relative humidity (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003eKI-solution at 220 nm \u0026lt; 3.3 Abs\/ \u0026lt; 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface Languages\u003c\/td\u003e\n\u003ctd\u003ebg, cn, cz, da, en, es, fr, gr, hr, hu, it, jp, kr, nl, pl, pt, ro, ru, sl, sl, sv, tr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Programs\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Reproducibility\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Selection\u003c\/td\u003e\n\u003ctd\u003eAutomatic, based on method selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51110906560827,"sku":"90-4770-50-EA","price":14618.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-4770-50.png?v=1785308658","url":"https:\/\/preiser.com\/products\/dr6000-uv-vis-spectrophotometer-without-rfid-100-240-v-hach-lpv441-99-00002","provider":"Preiser Scientific","version":"1.0","type":"link"}