{"product_id":"dual-star-meter-with-electrode-stand-universal-power-adapter-927007md-stainless-steel-atc-probe","title":"Dual STAR Meter with Electrode Stand; Universal Power Adapter; 927007MD Stainless Steel ATC Probe","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Dual STAR™ Meter with Electrode Stand; Universal Power Adapter; 927007MD Stainless Steel ATC Probe, 2115000\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eView large, individual measurements on full screen display or quickly toggle to split screen display to view two measurements at same time\u003c\/li\u003e\n\u003cli\u003eMeasure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using meter’s two BNC, reference pin-tip and ATC temperature inputs\u003c\/li\u003e\n\u003cli\u003eMeter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so meter displays more accurate results faster\u003c\/li\u003e\n\u003cli\u003eEasy-to-follow on-screen text prompts for calibration and setup menus available in multi-language user interface with English, Spanish, French, German or Italian options\u003c\/li\u003e\n\u003cli\u003eEZ Startup menu facilitates quick and easy first-time meter setup\u003c\/li\u003e\n\u003cli\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/li\u003e\n\u003cli\u003eSelectable read modes include \u003cem\u003eAuto-Read\u003c\/em\u003e, \u003cem\u003eOn-Ready\u003c\/em\u003e, \u003cem\u003eAt Timed Intervals\u003c\/em\u003e, \u003cem\u003eContinuous\u003c\/em\u003e, \u003cem\u003eValue Change\u003c\/em\u003e \u003cem\u003ein Measurement\u003c\/em\u003e and \u003cem\u003eTimed\u003c\/em\u003e for variety of measurement collection methods for different analytical methods\u003c\/li\u003e\n\u003cli\u003ePerform up to 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/li\u003e\n\u003cli\u003ePerform up to 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/li\u003e\n\u003cli\u003eEasily transfer data via USB and RS232 to printer or computer with free Orion Dual Star Com™ communication software\u003c\/li\u003e\n\u003cli\u003eStir samples with ease using meter-controlled Orion Star stirrer probe\u003c\/li\u003e\n\u003cli\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e927007MD Orion stainless steel ATC probe\u003c\/li\u003e\n\u003cli\u003eElectrode stand\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter\u003c\/li\u003e\n\u003cli\u003eLiterature\u003c\/li\u003e\n\u003cli\u003eComputer interface cable\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e                                                                                                                                               \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Adapter\u003c\/td\u003e\n\u003ctd\u003eUniversal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (ISE)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05 of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Temperature)\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (mV)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (pH)\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eLinear point to point, non-linear selectable auto-blank, incremental techniques including single known addition and subtraction, double known addition and subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e2 to 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\/Compliance\u003c\/td\u003e\n\u003ctd\u003eIP-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions, L x W x H\u003c\/td\u003e\n\u003ctd\u003e24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e90 to 260 VAC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH (adjustable), 1.000 ISE (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eNumeric with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and Timed Reading; manual data logging with Continuous measurement mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOrion Dual Star pH\/ISE\/mV\/RmV\/ORP\/Temperature Dual Channel Benchtop Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUniversal 90-260 VAC (included), 50-60 Hertz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProbe Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (ISE)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 19999 in ppm, M, %, ppb or unitless\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (ORP)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (pH)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-2.000 to 19.999 pH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Relative Humidity)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 to 85 %, non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Relative mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±1999.9 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (Temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-5.0 °C to +105.0 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (ISE)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUp to 3 significant digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (mV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 mV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (pH)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1, 0.01, 0.001 pH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution (Temperature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSmart Stability and Smart Averaging\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature (English) Operating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e41 to 113 °F\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature (Metric) Operating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 to 45 °C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Probe Calibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 point temperature offset calibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemperature Selection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManual or automatic with ATC temperature probe\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWarranty\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e3 year meter replacement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.9 kg (2 lb)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041302843,"sku":"91-2654-23-EA","price":2560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-23_ee2cd231-5535-484d-a857-a9493e647a53.png?v=1784707763","url":"https:\/\/preiser.com\/products\/dual-star-meter-with-electrode-stand-universal-power-adapter-927007md-stainless-steel-atc-probe","provider":"Preiser Scientific","version":"1.0","type":"link"}