{"product_id":"genesys-40-visible-spectrophotometer-thermo-scientific-840-297000","title":"GENESYS 40 Visible Spectrophotometer, Thermo Scientific, 840-297000","description":"\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eThermo Scienitific™ GENESYS™ 40 Visible Spectrophotometer, 840-297000Features:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003e\u003c\/strong\u003eVisible spectral range\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eDual-beam\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eSingle-cell configuration\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eMeets all specifications for precise chemical measurements as well as critical quality control applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003e7 in. high-resolution touchscreen user interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eNo PC required — controlled locally for speed and reliability\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eWi-Fi ready for networking capabilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eLarge, washable sample compartment with front access for easy use and maintenance\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eSloping top surface designed to shed spills\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eData resolutions from 0.2 to 5 nm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003e2-year standard warranty — warranty will be extended 1 more year if instrument is registered with Thermo Scienitific™ within 6 months of purchase\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eChemistry laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eRoutine measurements\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-size:\" small\u003eModerate throughput requirements\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003ctable frame=\"border\" rules=\"all\" style=\"border-color:\" align=\"center\" border=\"1\" border-width:=\"\" width:=\"\" height:=\"\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eBaseline Flatness\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e± 0.005 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eCompartments\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size:\" small\u003eAccessible from top, front, or side;\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003eAble to accommodate up to 100 mm cells;\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003eAvailable accessory for up to 25 mm diameter x 150 mm height test tubes;\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003eRemovable, washable sample compartment liner with magnetic hold-down and placement\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eConnections\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size:\" small\u003eSingle USB-A supports flash memory devices for method and data storage\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003eDuplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, and mouse;\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003eExport data to network or PC via USB, Ethernet, or Wi-Fi\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDescription\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eGENESYS™ 40 Visible Spectrophotometer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDetector Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eDual Silicon Photodiodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDimensions, \u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003e(L x W x H)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e35.5 x 38.5 x 19.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e7-inch color touchscreen, fixed, high definition, 800 x 1280 pixels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDrift\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e\u0026lt; 0.0005 A\/Hr (At 500 nm after 1 hour warmup)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eKeypad\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eTouchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eLamp\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eTungsten-Halogen (\u0026gt; 1000 hours)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eNoise\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e(RMS at 500 nm 60 consecutive measurements)\u003c\/span\u003e\u0026lt;\/= 0.00020 A @ 0 A @ 260 and 500 nm\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e\u0026lt;\/= 0.00030 A @ 1 A @ 260 and 500 nm\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e\u0026lt;\/= 0.00040 A @ 2 A @ 260 and 500 nm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eOptical Design\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eDual beam\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003ePhotometric\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color:\"\u003e\n\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eInstrument\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size:\" small\u003e± 0.002 A @ 0.5 A\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e± 0.004 A @ 1.0 A\u003c\/span\u003e\u003cspan style=\"font-size:\" small\u003e± 0.008 A @ 2.0 A\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e- 3 A to + 5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e- 3 A to + 3.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e± 0.001 A @ 1 A (measured at 1.0 A at 546 nm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003ePower Requirements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eExternal AC to DC converter, Voltage and Frequency (Hz) are selected automatically, 100 to 240 V, 50 to 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003ePrinter\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003eSnap-on printer (optional—purchase separately)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e0.2 nm. 0.5 nm, 1 nm, 2 nm, 5 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eSpectral Bandwidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e5 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eStray Light\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e\u0026lt; 0.05% T at 340 nm and 400 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eWavelength\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e± 0.5 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e325 nm to 1100 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e\u0026lt; ± 0.2 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eScan Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003eAutomatic — up to 1800 nm\/min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background-color:\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size:\" small\u003e7.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51110907117883,"sku":"90-4770-78-EA","price":5150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-4770-78.png?v=1784704157","url":"https:\/\/preiser.com\/products\/genesys-40-visible-spectrophotometer-thermo-scientific-840-297000","provider":"Preiser Scientific","version":"1.0","type":"link"}