{"product_id":"hq2200-2-channel-portable-multi-meter-ph-conductivity-tds-salinity-dissolved-oxygen-do-orp-without-electrodes-hach-lev015-53-2200a","title":"HQ2200 2-Channel Portable Multi-Meter pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP, without Electrodes, HACH,  LEV015.53.2200A","description":"\u003cp\u003e\u003cstrong\u003eHACH® HQ2200 2-Channel Portable Multi-Meter pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP, without Electrodes, LEV015.53.2200A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIllustrated, step-by-step, on-screen calibration procedures to make calibration a breeze\u003c\/li\u003e\n\u003cli\u003eIntelliCAL\u003csup\u003e?\u003c\/sup\u003e smart sensors available separately with HQ Series to measure wide variety of parameters including Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature, Conductivity, and pH — purchase the sensors to customize instrument for your application\u003c\/li\u003e\n\u003cli\u003eIntelliCAL\u003csup\u003e? \u003c\/sup\u003esensors are automatically recognized by meter and retain their calibration history and methods settings and can be switched between multiple meters as needed\u003c\/li\u003e\n\u003cli\u003eThese sensors deliver superior accuracy and response times\u003c\/li\u003e\n\u003cli\u003eData from your lab or field work can be safely transferred from meter to computer via USB\u003c\/li\u003e\n\u003cli\u003eHACH has over 80 years electrochemistry expertise and provide reliable technical support and field service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHQ2200 Portable pH\/ORP\/EC\/TDS\/DO Multi-Meter, 2 channels\u003c\/li\u003e\n\u003cli\u003eManuals\u003c\/li\u003e\n\u003cli\u003eLi-Ion batteries, rechargeable\u003c\/li\u003e\n\u003cli\u003eUSB charger with cable for USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature correction\u003c\/td\u003e\n\u003ctd\u003eNone; Linear; NaCl Non-Linear Natural Water.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories Included\u003c\/td\u003e\n\u003ctd\u003eUSB charger, power cable, and clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Buffer Recognition\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Measurement\u003c\/td\u003e\n\u003ctd\u003eAutomatic compensation of DO when using an LDO or LBOD probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eDemal (1 D\/ 0.1 D\/ 0.01 D); Molar (0.1 M\/ 0.01 M\/0.001 M); NaCl (0.05%; 25 µS\/cm; 1000 µS\/cm; 18 mS\/cm); Standard sea water; User defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Intervals\/Alerts\/Reminder\u003c\/td\u003e\n\u003ctd\u003eOff, selectable from 2 hours to 7 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Measurement Range\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom Calibration Standards\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e10,000 data points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003eAutomatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eUp to 3 parameters at a time, dependent on HQ model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e536 x 336 Mono-TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP67 (with battery compartment installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP Features\u003c\/td\u003e\n\u003ctd\u003eDate; Time; Sample ID; Operator ID, Calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument\u003c\/td\u003e\n\u003ctd\u003ePortable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Direct Measurement Range\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Electrode Calibration\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit?\u003c\/td\u003e\n\u003ctd\u003eMeter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT \u0026amp; BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLock Function\u003c\/td\u003e\n\u003ctd\u003eContinuous \/ Auto-stabilization (\"press to read\") \/ At Interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eProbe specific programmed method settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHQ2200 Multi\/2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Measurement at Stable Reading\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Measurement Range\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Error Messages\u003c\/td\u003e\n\u003ctd\u003eClear text error messages displayed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003eSoft Touch Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode Calibration\u003c\/td\u003e\n\u003ctd\u003ePredefined ORP standards (including Zobell's solution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003epH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eColour-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45; DIN: 1.09, 4.65, 9.23; User-defined custom buffer sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode calibration\u003c\/td\u003e\n\u003ctd\u003e1 - 3 Calibration points\u003cbr\u003eCalibration summary data logged and displayed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003eSelectable:\u003cbr\u003e0.001\/0.01\/0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003eIntellical Standard Laboratory or Rugged Field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbes included\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIEC Class III (SELV (Separated\/Safety Extra-Low Voltage) powered); external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 (ppt) (‰)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor A\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor B\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor C\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Conditions\u003c\/td\u003e\n\u003ctd\u003e-20 - 60 °C, max. 90% relative humidity (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L - 0.1 g\/L upon measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic Temperature compensation for pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd\u003e°C or °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of measurement\u003c\/td\u003e\n\u003ctd\u003eField Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111188988219,"sku":"92-1625-41-EA","price":1744.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-1625-41.png?v=1784711537","url":"https:\/\/preiser.com\/products\/hq2200-2-channel-portable-multi-meter-ph-conductivity-tds-salinity-dissolved-oxygen-do-orp-without-electrodes-hach-lev015-53-2200a","provider":"Preiser Scientific","version":"1.0","type":"link"}