{"product_id":"humidity-test-chamber-24-7-cu-ft-700-l-200-240-v-50-60-hz-binder-inc-9020-0325","title":"Humidity Test Chamber, 24.7 Cu Ft (700 L), 200 - 240 V (50\/60 Hz), Binder Inc, 9020-0325","description":"\u003cp\u003e\u003cstrong\u003eBinder® Humidity Test Chamber, 24.7 Cu Ft (700 L), 200 - 240 V (50\/60 Hz), 9020-0325\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafe thanks to climatic homogeneity that far exceeds accuracy required by ICH guidelines, even with fully loaded unit\u003c\/li\u003e\n\u003cli\u003eReliable thanks to fail-safe operation without compromise\u003c\/li\u003e\n\u003cli\u003eIinterior and long-life evaporator plate made entirely from stainless steel\u003c\/li\u003e\n\u003cli\u003eSmart – wide range of accessories makes it highly compatible for adaptation to specific customer requirements\u003c\/li\u003e\n\u003cli\u003eEconomical thanks to maximum effective volume which allows for 30% larger load compared to competition\u003c\/li\u003e\n\u003cli\u003eTemperature range: 0 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003eHumidity range: 10 % to 80 % RH\u003c\/li\u003e\n\u003cli\u003eAPT.line™ preheating chamber technology\u003c\/li\u003e\n\u003cli\u003eHumidity regulation with capacitive humidity sensor and vapor humidification\u003c\/li\u003e\n\u003cli\u003eIntuitive touchscreen controller with time-segment and real-time programming\u003c\/li\u003e\n\u003cli\u003eBINDER Multi Management Software APT-COM™ Basic Edition\u003c\/li\u003e\n\u003cli\u003eInternal data logger, measured values can be read out in open format via USB\u003c\/li\u003e\n\u003cli\u003eUnit self-test for comprehensive status analysis\u003c\/li\u003e\n\u003cli\u003eTight-sealing inner door made of safety glass (ESG)\u003c\/li\u003e\n\u003cli\u003eAvoidance of glass corrosion by special TIMELESS coating\u003c\/li\u003e\n\u003cli\u003eInner chamber made of stainless steel\u003c\/li\u003e\n\u003cli\u003e2 stainless steel racks\u003c\/li\u003e\n\u003cli\u003eAccess port with silicone plug, 30 mm, left\u003c\/li\u003e\n\u003cli\u003e4 stable castors, two with brakes, from 240 liters\u003c\/li\u003e\n\u003cli\u003eClass 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm\u003c\/li\u003e\n\u003cli\u003eComputer interface: Ethernet\u003c\/li\u003e\n\u003cli\u003eDoor heating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption model\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder number\u003c\/td\u003e\n\u003ctd\u003e9020-0325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. heat compensation at 40 °C [W]\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature fluctuation [± K]\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range [°C]\u003c\/td\u003e\n\u003ctd\u003e0…70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature variation at 40 °C [± K]\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity fluctuation at 25 °C and 60 % RH\u003c\/td\u003e\n\u003ctd\u003e1,5 ± % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity fluctuation at 40 °C and 75 % RH\u003c\/td\u003e\n\u003ctd\u003e1,5 ± % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity range\u003c\/td\u003e\n\u003ctd\u003e10…80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery time after 30 seconds door open at 25 °C and 60 % RH [min]\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery time after 30 seconds door open at 40 °C and 75 % RH [min]\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature fluctuation at 25 °C and 60 % RH [± K]\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature fluctuation at 40 °C and 75 % RH [± K]\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range [°C]\u003c\/td\u003e\n\u003ctd\u003e10…70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature variation at 25 °C and 60 % RH [± K]\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature variation at 40 °C and 75 % RH [± K]\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal power [kW]\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase (Nominal voltage)\u003c\/td\u003e\n\u003ctd\u003e1~\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower frequency [Hz]\u003c\/td\u003e\n\u003ctd\u003e50\/60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage [V]\u003c\/td\u003e\n\u003ctd\u003e200…240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit fuse [A]\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner doors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit doors\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth net [in]\u003c\/td\u003e\n\u003ctd\u003e35.07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight net [in]\u003c\/td\u003e\n\u003ctd\u003e75.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth net [in]\u003c\/td\u003e\n\u003ctd\u003e49.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth [in]\u003c\/td\u003e\n\u003ctd\u003e22.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight [in]\u003c\/td\u003e\n\u003ctd\u003e49.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth [in]\u003c\/td\u003e\n\u003ctd\u003e38.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior volume [cu.ft.]\u003c\/td\u003e\n\u003ctd\u003e24.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad per rack [lbs]\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight of the unit (empty) [lbs]\u003c\/td\u003e\n\u003ctd\u003e688\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted load [lbs]\u003c\/td\u003e\n\u003ctd\u003e331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall clearance back [in]\u003c\/td\u003e\n\u003ctd\u003e3.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall clearance sidewise [in]\u003c\/td\u003e\n\u003ctd\u003e11.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound-pressure level [dB(A)]\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy consumption at 40 °C and 75 % RH [Wh\/h]\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of shelves (std.\/max.)\u003c\/td\u003e\n\u003ctd\u003e2\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111047201083,"sku":"91-2677-26-EA","price":24228.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2677-26_880ba3a8-4325-4b2f-8877-e82e23d0b924.png?v=1784707956","url":"https:\/\/preiser.com\/products\/humidity-test-chamber-24-7-cu-ft-700-l-200-240-v-50-60-hz-binder-inc-9020-0325","provider":"Preiser Scientific","version":"1.0","type":"link"}