{"product_id":"intellical-lbod101-luminescent-optical-dissolved-oxygen-ldo-sensor-for-bod-measurements-1-m-cable","title":"Intellical LBOD101 Luminescent\/Optical Dissolved Oxygen (LDO) Sensor for BOD Measurements, 1 m Cable","description":"\u003cp\u003e\u003cstrong\u003eHACH™ Intellical LBOD101 Luminescent\/Optical Dissolved Oxygen (LDO) Sensor for BOD Measurements, 1 m Cable, LBOD10101\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"overviewSection\"\u003e\n\u003cdiv class=\"productDescription\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntellical™ LBOD101 is the latest embodiment of Hach’s patented Luminescent Dissolved Oxygen (LDO) technology\u003c\/li\u003e\n\u003cli\u003eA digital, luminescent dissolved oxygen (LDO) sensor with a replaceable, integrated stirring system\u003c\/li\u003e\n\u003cli\u003eMeasures the dissolved oxygen for BOD (Biochemical Oxygen Demand) determination in BOD bottles in BOD\u003csub\u003e5\u003c\/sub\u003e testing applications\u003c\/li\u003e\n\u003cli\u003eUsed for initial and final dissolved oxygen measurements\u003c\/li\u003e\n\u003cli\u003eFitted with an automatic pressure sensor module\u003c\/li\u003e\n\u003cli\u003eDO sensing cap comes with an iButton to track days in use and remind remaining life of the sensing cap element\u003c\/li\u003e\n\u003cli\u003eImproves confidence in the BOD5 testing procedure by reducing variance and maintenance while increasing stability, accuracy, precision, and efficiency (tests per unit time)\u003c\/li\u003e\n\u003cli\u003eLow maintenance requirements keeps lab down-time to a minimum\u003c\/li\u003e\n\u003cli\u003eProvides ultimate traceability in measurement history\u003c\/li\u003e\n\u003cli\u003eProbes can be moved between meters without the need to re-calibrate or re-enter measurement settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"height: 438px; width: 61.1704%; border-collapse: collapse; margin-left: auto; margin-right: auto;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 36px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 36px;\"\u003e±0.05 mg\/L from 0 to 10 mg\/L; ±0.1 mg\/L for greater than 10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e1.8 m (5.91 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eProbe Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e215 mm (8.46 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003ePressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e±3 mbar (0.3 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003ePressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e5 mbar (0.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e0.05 to 20.0 mg\/L; 1 to 200% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e0.01\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eMinimum Sample Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e10 mm (0.394 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eSaturation Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e±0.59% or reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eSaturation Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eSensor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003ePolycarbonate\/ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eSensor Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003eLumiphore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eSpecial Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003eIntegrated stirring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e±0.3 °C (±0.54 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003e0.1 °C (0.18 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 34.6591%; height: 18px;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%; height: 18px;\"\u003eATC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6591%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%;\"\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 34.6591%;\"\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 65.3409%;\"\u003eLDO Sensor, DO cap with its iButton (already mounted), test certificate and basic user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111579582779,"sku":"HAH-LBOD10101-EA","price":1755.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/HAH-LBOD10101.png?v=1784719473","url":"https:\/\/preiser.com\/products\/intellical-lbod101-luminescent-optical-dissolved-oxygen-ldo-sensor-for-bod-measurements-1-m-cable","provider":"Preiser Scientific","version":"1.0","type":"link"}