{"product_id":"intellical-water-quality-laboratory-refillable-ph-electrode-1-m-cable-hach-phc28101","title":"IntelliCAL Water Quality Laboratory Refillable pH Electrode, 1 m Cable, HACH, PHC28101","description":"\u003cp\u003e\u003cstrong\u003eHACH® IntelliCAL® Water Quality Laboratory Refillable pH Electrode, 1 m Cable, PHC28101\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital combination electrode with built-in temperature sensor\u003c\/li\u003e\n\u003cli\u003eDesigned for premium performance, refillable electrode is ideal even in difficult samples such as Low Ionic Strength (LIS), Ultrapure, dirty samples and samples with high solids content\u003c\/li\u003e\n\u003cli\u003eHigh electrolyte flow rate and large open junction design provide fast response and stabilization\u003c\/li\u003e\n\u003cli\u003eShockproof with its Zeonor plastic body protecting down to glass bulb sensing element\u003c\/li\u003e\n\u003cli\u003eAlerts user when re-calibration is needed — no guesswork need for accurate, reliable results\u003c\/li\u003e\n\u003cli\u003eStores time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number all for the ultimate in traceability\u003c\/li\u003e\n\u003cli\u003eIntelliCAL® electrodes can be moved between meters without need to re-calibrate or re-enter measurement settings\u003c\/li\u003e\n\u003cli\u003eNot suitable for use in organic solvents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntelliCAL PHC281 Laboratory pH electrode\u003c\/li\u003e\n\u003cli\u003eStorage soaker bottle\u003c\/li\u003e\n\u003cli\u003e1 m cable\u003c\/li\u003e\n\u003cli\u003e59-mL bottle reference electrolyte filling solution (2.44 M KCl solution)\u003c\/li\u003e\n\u003cli\u003eTest certificate\u003c\/li\u003e\n\u003cli\u003eBasic User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eLow Ionic Strength \u0026amp; Dirty Samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Type\u003c\/td\u003e\n\u003ctd\u003eRefillable Reference Element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilling Solution\u003c\/td\u003e\n\u003ctd\u003e2.44 M KCl solution (#2965026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction\u003c\/td\u003e\n\u003ctd\u003eOpen Junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit?\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod Type\u003c\/td\u003e\n\u003ctd\u003eLaboratory: Refillable Reference Element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Kit\u003c\/td\u003e\n\u003ctd\u003eModel: PHC281\u003cbr\u003eAccessories Included: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Type\u003c\/td\u003e\n\u003ctd\u003eAg\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001\/0.01\/0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample depth\u003c\/td\u003e\n\u003ctd\u003e15 mm (0.59 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor material\u003c\/td\u003e\n\u003ctd\u003eZeonor™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003epH Glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Features\u003c\/td\u003e\n\u003ctd\u003eDouble junction reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C (0.18 degrees F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest requirements\u003c\/td\u003e\n\u003ctd\u003eParameter Needed: pH\u003cbr\u003eMinimum Sample Depth (mm): 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor\u003c\/td\u003e\n\u003ctd\u003eATC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhat's included?\u003c\/td\u003e\n\u003ctd\u003eIntelliCAL PHC281 Laboratory pH electrode with storage soaker bottle, 1 m cable, 59-mL bottle reference electrolyte filling solution (2.44 M KCl solution), Test certificate, and Basic User Manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"HACH","offers":[{"title":"EA (1)","offer_id":51111043498299,"sku":"91-2661-71-EA","price":737.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2661-71_4a5d95c4-477f-4442-b96c-6a9a34c27398.png?v=1784707832","url":"https:\/\/preiser.com\/products\/intellical-water-quality-laboratory-refillable-ph-electrode-1-m-cable-hach-phc28101","provider":"Preiser Scientific","version":"1.0","type":"link"}