{"product_id":"lindberg-blue-m-lgo-box-furnace-with-digital-with-over-temperature-protection-single-set-point-controller-100-degrees-c-to-1200-degrees-c-55-3-l-bf51841bc-1","title":"Lindberg\/Blue M LGO Box Furnace with Digital with Over Temperature Protection, Single Set-Point Controller, 100 degrees C to 1200 degrees C, 55.3 L, BF51841BC-1","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ \u003c\/strong\u003e\u003cstrong\u003eLindberg\/Blue M™ LGO Box Furnace with Digital with Over Temperature Protection, Single Set-Point Controller, 100 degrees C to 1200 degrees C, 55.3 L, BF51841BC-1\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFeature propretary light gauge overbend (LGO) heating elements\u003c\/li\u003e\n\u003cli\u003eChoice of side hinge or vertical lift door\u003c\/li\u003e\n\u003cli\u003eAir vent (1 in. diameter, top) and air inlet (0.375 in. diameter, rear) for inert atmosphere exchange (may experience some leakage at door)\u003c\/li\u003e\n\u003cli\u003eSelf-tuning, digital instrumentation for precise temperature setpoint and display\u003c\/li\u003e\n\u003cli\u003ePlatinel II™ thermocouple for long-term stability\u003c\/li\u003e\n\u003cli\u003e0.6 cu. ft. models feature vertical lift door; 2 cu. ft. models feature horizontal side swing door, hot side facing away from operator for protection\u003c\/li\u003e\n\u003cli\u003eMicroprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot\u003c\/li\u003e\n\u003cli\u003eControl panel designed for easy access and maintenance\u003c\/li\u003e\n\u003cli\u003eMain power ON\/OFF switch on control panel\u003c\/li\u003e\n\u003cli\u003eAdjustable high-limit overtemperature protection\u003c\/li\u003e\n\u003cli\u003eSimultaneous LED display of actual temperature vs. setpoint\u003c\/li\u003e\n\u003cli\u003eCan be configured to display temperature in either degrees C or degrees F\u003c\/li\u003e\n\u003cli\u003eSafety door switch interrupts power to heating element when door is opened; protects heating elements and minimizes exposure to end-user\u003c\/li\u003e\n\u003cli\u003eRemovable shelves for versatility\u003c\/li\u003e\n\u003cli\u003eMoldatherm™ hearthplate supports load and prevents damage due to spillage\u003c\/li\u003e\n\u003cli\u003eAvailable controllers:\u003cul\u003e\n\u003cli\u003eDigital single segment, single setpoint, one ramp to setpoint\u003c\/li\u003e\n\u003cli\u003eDigital single program with multiple segments for ramp (up and down) and dwell (timed hold) temperature control\u003c\/li\u003e\n\u003cli\u003eDigital multiple programs and segments for ramp (up and down) and dwell (timed hold) temperature control (models with (P) suffix\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable digital overtemperature control (OTC)*, available on selected models with (B) suffix\u003cul\u003e\n\u003cli\u003eProtects furnace and load in event of primary control circuit failure\u003c\/li\u003e\n\u003cli\u003eOverrides main controller and shuts off power to furnace if high limit is reached\u003c\/li\u003e\n\u003cli\u003eManual reset required for safety\u003c\/li\u003e\n\u003cli\u003eOperates via magnetic contacts through signal from independent thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlowmeter Option (FM suffix models) Inert atmosphere only\u003cul\u003e\n\u003cli\u003eGas flowmeter, adjustable, located on front control panel\u003c\/li\u003e\n\u003cli\u003eAdjustable flowrate, range 1.0 to 10.0 cu. ft.\/hr. standard\u003c\/li\u003e\n\u003cli\u003eSuitable for inert gas or airflow to chamber\u003c\/li\u003e\n\u003cli\u003eAllows fresh air exchange for ashing applications Not suitable for combustible or volatile gases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eOne two-part shelf (0.6 cu. ft. models have one shelf position at center position; 2.0 cu. ft. models have three shelf positions)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRequired power cord and hardwiring not included\u003c\/li\u003e\n\u003cli\u003eOptional RS485 Digital Communications Port allows controller to be connected to a PC for remote monitoring and control of the furnace; up to 30 units can be connected to one PC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e*Specify Option B when ordering\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e\u003csmall\u003e Actual product may differ from image shown\u003c\/small\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51110986580283,"sku":"90-8545-72-EA","price":14400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-8545-72.png?v=1785310555","url":"https:\/\/preiser.com\/products\/lindberg-blue-m-lgo-box-furnace-with-digital-with-over-temperature-protection-single-set-point-controller-100-degrees-c-to-1200-degrees-c-55-3-l-bf51841bc-1","provider":"Preiser Scientific","version":"1.0","type":"link"}