{"product_id":"myron-l-ds-meter-conductivity-meter-0-5-000-microsiemens-or-micromhos-cm-becker-equipment-512m5","title":"Myron L DS Meter Conductivity Meter, 0-5,000 Microsiemens (or Micromhos)\/cm, Becker Equipment, 512M5","description":"\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eMyron L® DS Meter™ Conductivity Meter, 0-5,000 Microsiemens (or Micromhos)\/cm, Model \u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e512M5\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eDS Meter™ Conductivity Meters provide fast, accurate, on-the-spot measurements of conductivity in water.  This handheld instrument may be used to monitor impurities in industrial, commercial or natural source waters that can contribute to scale, corrosion, poor taste, or environmental pollution effecting animal and plant life.  Readings from the highly stable circuitry help assure product quality, prevent equipment damage or failure, and verify in-line instrumentation.Breakage is one the major causes of sensor failure in a typical conductivity instrument.  The \u003cspan style=\"font-size: small;\"\u003eDS Meter™ electrode has maximum protection inside the cell cup.  \u003c\/span\u003eThe lighweight and compact, yet durable, field-tested design places these instruments among the world's most reliable and should provide years of rough field service with reliability, accuracy, and simplicity.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003c\/strong\u003eBoilers \u0026amp; Cooling towers\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eDeionization\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eReverse osmosis\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eChemical concentrations\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003ePrinting fountain solutions\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eSwimming pools \u0026amp; spas\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eWater polution control\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003eWastewater\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003ctable frame=\"border\" rules=\"all\" style=\"border-color: #000000; border-width: 1px; width: 588px; height: 421px;\" align=\"center\" border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eConductivity range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e 0-5,000 micromhos (M)\/cm or 0-5,000 microsiemens (S)\/cm; also in ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSingle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e2-1\/2 in. Taut-band shock-resistant meter; Analog\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e ± 2% full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e ± 1% \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eTemperature compensation \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic (to 25 °C \/ 77°F) for conductivity samples between 10-71 °C \/ 50-160 °F  \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eCell cup material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003echip and crack-resistant polyethylene\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003ePowered by\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eSingle 9 volt battery (included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e \u0026gt; 2000 tests or 1 year)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eConductivity Electrode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eBuilt-in: never needs re-platinizing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eMinimal due to very stable circuitry; internal standard for easy field conductivity calibration and range doubling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e3.4\" W x 4.5\" D x 4.0\" H \/ 86 mm W x 114 mm D x 102 mm \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 lb \/ 0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-family: Arial;\" face=\"Arial\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51111216873787,"sku":"92-2651-19-EA","price":243.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2651-19.png?v=1784712184","url":"https:\/\/preiser.com\/products\/myron-l-ds-meter-conductivity-meter-0-5-000-microsiemens-or-micromhos-cm-becker-equipment-512m5","provider":"Preiser Scientific","version":"1.0","type":"link"}