{"product_id":"orion-conductivity-tds-salinity-resistivity-benchtop-meter-kit-with-duraprobe-4-cell-conductivity-sensor-solutions-and-stand-thermo-scientific-stara2125","title":"Orion Conductivity\/TDS\/Salinity\/Resistivity Benchtop Meter Kit with DuraProbe 4-cell Conductivity Sensor, Solutions and Stand, Thermo Scientific, STARA2125","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Conductivity\/TDS\/Salinity\/Resistivity Benchtop Meter Kit with DuraProbe 4-cell Conductivity Sensor, Solutions and Stand, STARA2125\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerform up to a five-point conductivity calibration with calibration editing option that allows individual points to be fixed without full recalibration\u003c\/li\u003e\n\u003cli\u003eAuto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate\u003c\/li\u003e\n\u003cli\u003eUse linear, non-linear, EP (USP) or off conductivity temperature compensation with 5, 10, 15, 20 or 25 °C reference temperatures\u003c\/li\u003e\n\u003cli\u003eInformative, easy-to-read, backlit graphic display with clear onscreen instructions simplifies operation\u003c\/li\u003e\n\u003cli\u003eCapture your critical readings with measurement stability indicator and selectable read modes — \u003cem\u003eAuto-Read\u003c\/em\u003e holds a stable reading, \u003cem\u003eContinuous\u003c\/em\u003e shows changing readings with hold option and \u003cem\u003eTimed\u003c\/em\u003e logs data at specific intervals\u003c\/li\u003e\n\u003cli\u003eEliminate need for magnetic stir bars using optional meter-controlled stirrer probe (catalog number 096019) to uniformly mix solutions\u003c\/li\u003e\n\u003cli\u003eData log collects and date\/time stamps up to 2000 measurement sets with optional sample ID and user ID\u003c\/li\u003e\n\u003cli\u003eCalibration log stores 10 most recent calibrations\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory ensures your data and settings are protected, even with loss of power\u003c\/li\u003e\n\u003cli\u003eOrion Star Com software facilitates data transfer to  computer via USB or RS232 connections\u003c\/li\u003e\n\u003cli\u003eFlexible power options with universal power adapter or optional AA batteries\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing resists dust and splashes, and can be wall-mounted if table space is limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A212 conductivity meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e91-2638-91\u003c\/span\u003e DuraProbe 4-cell conductivity sensor (Orion™ P\/N 013005MD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e17-7109-02\u003c\/span\u003e 1413 μS conductivity standard, 5 x 60 mL (Orion™ P\/N 011007)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e91-2639-61\u003c\/span\u003e Electrode stand Orion™ P\/N STARA-BEA\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e91-2639-68\u003c\/span\u003e Universal power adapter (Orion™ P\/N 1010003)\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e91-2639-13\u003c\/span\u003e Computer interface cable (Orion™ P\/N 1010053)\u003c\/li\u003e\n\u003cli\u003eMeter test certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Probes\u003c\/td\u003e\n\u003ctd\u003e2-cell or 4-cell conductivity sensors with built-in temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eConductivity with calibration editing option and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.001 μS minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit \u0026gt; 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Metric) Reference\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.01 psu or 0.01 ppt minimum, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Modes\u003c\/td\u003e\n\u003ctd\u003ePractical salinity (psu) or natural sea water (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor Range\u003c\/td\u003e\n\u003ctd\u003eLinear (0.02 to 9.99)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Temperature)\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Temperature)\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD with Backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous mode with hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003eConductivity sensor, stirrer probe (includes 013005MD Orion DuraProbe 4-cell conductivity sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eOrion Star A212 Conductivity\/TDS\/Salinity\/Resistivity\/Temperature Benchtop Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e1 ohm or 0.1 megohm, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eUniversal AC adapter (included) or 4 AA batteries (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111035928891,"sku":"91-2639-25-EA","price":2130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-25_41738678-c354-4000-b0ea-9abba9e2d6fc.png?v=1784707470","url":"https:\/\/preiser.com\/products\/orion-conductivity-tds-salinity-resistivity-benchtop-meter-kit-with-duraprobe-4-cell-conductivity-sensor-solutions-and-stand-thermo-scientific-stara2125","provider":"Preiser Scientific","version":"1.0","type":"link"}