{"product_id":"orion-dual-star-meter-ph-and-ammonia-kit-thermo-scientific-2115201","title":"Orion Dual Star Meter pH and Ammonia Kit, Thermo Scientific 2115201","description":"\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTwice the measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter.  Record accurate and reliable pH, ion concentrate, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab.  Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time\/date stamp and easily transfer to a printer or computer.  Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each sample separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThe Orion™ Dual Star™ pH\/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display. Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs. Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable. The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFeatures\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eView large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEZ Startup menu facilitates quick and easy first time meter setup\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNumeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eSelectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point pH calibration with automatic recognition for USA\/NIST and EURO\/DIN buffers with option to manually input custom buffer values\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003ePerform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single\/double known addition and single\/double known subtraction\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eNon-volatile meter memory holds up to 1000 data points with time and date stamp\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eEasily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eStir samples with ease using the meter-controlled Orion Star stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eMeter-attachable electrode stand assists with moving and maintaining electrodes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIP54-rated housing handles splashes and is wall-mountable to save space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eThree-year meter replacement warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKit Includes\u003c\/span\u003e\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eOrion Dual Star pH\/ISE benchtop meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e9512BNWP Orion Ammonia ion selective electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e8172BNWP ROSS Sure-Flow glass-body pH electrode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e927007MD Orion stainless steel ATC probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e096019 Orion Star series stirrer probe\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e951207 Orion 100 ppm ammonia standard (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e951211 Orion ammonia ISA ionic strength adjuster (475ml)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e810199 ROSS pH buffer and solution kit\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eElectrode stand, USB cable, universal power supply, literature and meter test certificate\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable style=\"width: 612px; height: 891px;\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-2.000 to 19.999pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.002pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1, 0.01, 0.001pH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Relative mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ORP)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±1999.9mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (mV)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, % or unit-less\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.2mV or ±0.05% of reading, whichever is greater\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003epH with calibration editing option, ion concentration (ISE) with calibration\u003c\/span\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eediting option, relative mV (RmV), ORP and temperature\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (pH)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points (ISE)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2 to 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eIsopotential Point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e7.000pH (adjustable), 1.000 ISE (adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eRange (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e-5.0° to 105.0°C, 22.0° to 221.0°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eResolution (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e0.1°C, 0.1°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eAccuracy (Temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e±0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Selection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eManual or automatic with ATC temperature probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eTemperature Probe Calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e1 point temperature offset calibration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eBacklight Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eYes, adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eDisplay Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eGraphic LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: arial,helvetica,sans-serif; font-size: small;\"\u003eKeypad\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eNumeric with menu-specific function keys and dual purposescroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV), ORP or ion concentration (ISE)with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSmart Stability and Smart Averaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read, On Ready, At Timed Intervals,Value Change in Measurement and Timed Reading measure modes,manual data logging with Continuous measure mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e1000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian and German\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003epH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Adapter\u003c\/td\u003e\n\u003ctd\u003eUniversal 50-60 Hz, 100-240 Vac power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eUniversal AC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Requirements\u003c\/td\u003e\n\u003ctd\u003e90 to 260Vac 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e41° to 113°F \/ 5° to 45°C (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity  Range\u003c\/td\u003e\n\u003ctd\u003e5 to 85%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e24 x 17 x 9cm (9.5 x 6.7 x 3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 lb. (0.9kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification Compliance\u003c\/td\u003e\n\u003ctd\u003eCE, TU 3-1, FCC Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041335611,"sku":"91-2654-24-EA","price":4070.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-24_ac43fd84-b631-4abf-80ef-f99963e33846.png?v=1784707765","url":"https:\/\/preiser.com\/products\/orion-dual-star-meter-ph-and-ammonia-kit-thermo-scientific-2115201","provider":"Preiser Scientific","version":"1.0","type":"link"}