{"product_id":"orion-dual-star-ph-ise-orp-benchtop-meter-with-8102bnuwp-ross-ultra-electrode-and-ss-atc-probe-orion-2115101","title":"Orion Dual Star pH\/ISE\/ORP Benchtop Meter with 8102BNUWP ROSS Ultra Electrode and SS ATC Probe, Orion 2115101","description":"\u003cdiv\u003e \u003c\/div\u003e\u003cspan style=\"\" times new roman font-family:=\"\" font-size:=\"\"\u003e  \u003cdiv\u003eThe Orion DUAL STAR\u003cspan style=\"\" font-family: times new roman font-size:\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003emeter makes it easy to do two things at once.\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/span\u003e\u003cdiv\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003e \u003c\/span\u003e\u003c\/div\u003e\u003cspan style=\"\" times new roman font-family:=\"\" font-size:=\"\"\u003e  \u003cp align=\"\" left\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eDual channel with simultaneously displayed measurements\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eLow concentration range reading stability\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eKnown addition and subtraction incremental methods\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003e5 language choices: English, Spanish, French, German and Italian\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eMeter prompts and shortcut keys\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eThermo Scientific Orion EZ Startup for quick and easy meter set up\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003eE\u003cspan style=\"\" font-family: times new roman font-size:\u003e\u003cspan style=\"\" font-size:\u003eH\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003eORP calibration capability\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e    \u003cli\u003e      \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: times new roman font-size:\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: times new roman font-size:\u003e10 methods stored per channel  retains calibrations among multiple electrodes           \u003cli\u003e            \u003cdiv align=\"\" left\u003e1000 point datalogging with time and date stamping\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eCalibration, high point and low point alarms\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eCalibration graph with slope data for on-screen viewing\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eStar stirrer probe controlled directly from the meter\u003c\/div\u003e\n\u003c\/li\u003e          \u003cli\u003e            \u003cdiv align=\"\" left\u003eAutosampler compatibility\u003c\/div\u003e\n\u003c\/li\u003e          \u003cp align=\"\" left\u003e \u003c\/p\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003epH\u003c\/strong\u003e \u003c\/p\u003e\u003c\/span\u003e          \u003cul\u003e            \u003cli\u003e              \u003cdiv align=\"\" left\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange - 2.000 to 19.999                   \u003cli\u003e                    \u003cdiv align=\"\" left\u003eResolution 0.1, 0.01, 0.001\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eRelative Accuracy  0.002\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Points 1 to 6\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eAuto-Buffer Recognition  \u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eUSA\/NIST and EURO\/DIN\u003c\/div\u003e\n\u003c\/li\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/li\u003e          \u003c\/ul\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e            \u003cp align=\"\" left\u003e\u003cstrong\u003eISE\u003c\/strong\u003e \u003c\/p\u003e\u003c\/span\u003e          \u003cul\u003e            \u003cli\u003e              \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange 0 to 19999                   \u003cli\u003e                    \u003cdiv align=\"\" left\u003eResolution 1, 2 or 3 significant digits\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eRelative Accuracy  0.2 mV or 0.05 %, whichever is greater\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eUnits ppm, ppb, M, % or unitless\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eTechnique Options    Single known addition and subtraction Double known addition and subtraction\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Points 2 to 6\u003c\/div\u003e\n\u003c\/li\u003e                  \u003cli\u003e                    \u003cdiv align=\"\" left\u003eCalibration Options Linear, point to point, non-linear selectable auto-blank \u003c\/div\u003e\n\u003c\/li\u003e                  \u003cp align=\"\" left\u003e\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e\u003cstrong\u003emV\/Rel mV\/ORP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e                  \u003cul\u003e                    \u003cli\u003e                      \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e\u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange  1999.9                           \u003cli\u003e                            \u003cdiv align=\"\" left\u003eResolution 0.1\u003c\/div\u003e\n\u003c\/li\u003e                          \u003cli\u003e                            \u003cdiv align=\"\" left\u003eRelative Accuracy  0.2 mV or 0.05 %, whichever is greater\u003c\/div\u003e\n\u003c\/li\u003e                          \u003cli\u003e                            \u003cdiv align=\"\" left\u003eE\u003cspan style=\"\" font-family: universltstd-light font-size:\u003e\u003cspan style=\"\" font-size:\u003eH\u003c\/span\u003e \u003c\/span\u003e\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eCalibration Capability  Yes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e                  \u003c\/ul\u003e                  \u003cp\u003e \u003c\/p\u003e\u003c\/span\u003e            \u003cspan style=\"\" font-family: universltstd-boldcn font-size:\u003e  \u003cp align=\"\" left\u003e\u003cstrong\u003eTemperature \u003c\/strong\u003e\u003c\/p\u003e\u003c\/span\u003e\u003cul\u003e  \u003cli\u003e    \u003cdiv align=\"\" left\u003e\n\u003cspan style=\"\" font-family: universltstd-light font-size:\u003eRange - 5 to 105 C         \u003cli\u003e          \u003cdiv align=\"\" left\u003eResolution 0.1 C\u003c\/div\u003e\n\u003c\/li\u003e        \u003cli\u003e          \u003cdiv align=\"\" left\u003eRelative Accuracy  0.1 C\u003c\/div\u003e\n\u003c\/li\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e        \u003cdiv align=\"\" left\u003e \u003c\/div\u003e\u003c\/span\u003e\u003cdiv align=\"\" left\u003e \u003c\/div\u003e\n\u003cdiv align=\"\" left\u003e \u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111041171771,"sku":"91-2654-20-EA","price":3030.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2654-20_414aead2-91da-497a-992c-6ec5e17fd9eb.png?v=1784707760","url":"https:\/\/preiser.com\/products\/orion-dual-star-ph-ise-orp-benchtop-meter-with-8102bnuwp-ross-ultra-electrode-and-ss-atc-probe-orion-2115101","provider":"Preiser Scientific","version":"1.0","type":"link"}