{"product_id":"orion-ph-ise-conductivity-dissolved-oxygen-portable-multiparameter-meter-kit-thermo-scientific-stara3295","title":"Orion pH\/ISE\/Conductivity\/Dissolved Oxygen Portable Multiparameter Meter Kit, Thermo Scientific, STARA3295","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A329 pH\/ISE\/Conductivity\/RDO\/DO Portable Meter Kit with ROSS Ultra Triode™ Low Maintenance Gel pH\/ATC Electrode, DuraProbe™ 4-cell Conductivity Sensor, RDO Optical DO Sensor, Solutions, Meter Armor and Field Case, STARA3295\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCombined convenience with benefits of pH\/ISE meter, conductivity meter and dissolved oxygen meter in one easy-to-use system\u003c\/li\u003e\n\u003cli\u003eMeasure pH, ion concentration, mV, relative mV or ORP with temperature on channel one; measure conductivity, TDS, salinity or resistivity with temperature on channel two; and measure dissolved oxygen in percent saturation or mg\/L with temperature using RDO optical DO probes or polarographic DO probes on channel three\u003c\/li\u003e\n\u003cli\u003eEasily view individual measurements on full screen display and quickly toggle to split screen display to view multiple measurements simultaneously\u003c\/li\u003e\n\u003cli\u003ePerform up to five point pH and ISE calibrations with calibration editing option that allows individual points to be fixed without a full recalibration\u003c\/li\u003e\n\u003cli\u003ePerform up to five point conductivity calibration\u003c\/li\u003e\n\u003cli\u003eAuto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate\u003c\/li\u003e\n\u003cli\u003eUse linear, non-linear, EP (USP) or off conductivity temperature compensation with 5 °C, 10 °C, 15 °C, 20 °C or 25 °C reference temperatures\u003c\/li\u003e\n\u003cli\u003eCalibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options\u003c\/li\u003e\n\u003cli\u003eAutomatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings\u003c\/li\u003e\n\u003cli\u003eInformative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation\u003c\/li\u003e\n\u003cli\u003eCapture your critical readings with measurement stability indicator and selectable read modes — \u003cem\u003eAuto-Read\u003c\/em\u003e holds stable reading, \u003cem\u003eContinuous\u003c\/em\u003e shows changing readings with hold option and \u003cem\u003eTimed\u003c\/em\u003e logs data at specific intervals\u003c\/li\u003e\n\u003cli\u003eData log collects and date\/time stamps up to 5000 measurement sets with optional sample ID and user ID\u003c\/li\u003e\n\u003cli\u003eCalibration log stores 10 most recent calibrations\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory ensures your data and settings are protected, even with loss of power\u003c\/li\u003e\n\u003cli\u003eOrion™ Star™ Com software facilitates data transfer to computer via USB or RS232 connections\u003c\/li\u003e\n\u003cli\u003eFlexible power options with AA batteries or optional universal power adapter\u003c\/li\u003e\n\u003cli\u003eIP67-rated housing is waterproof for rugged field operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar™ A329 pH\/ISE\/Conductivity\/RDO\/DO Meter with Batteries\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-53\u003c\/span\u003e\u003c\/span\u003e (8107UWMMD) ROSS™ Gel-filled Epoxy pH\/ATC Triode with 3 Meter Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-49\u003c\/span\u003e\u003c\/span\u003e (013010MD) DuraProbe™ Epoxy 4-Probe (K=0.475) Conductivity Probe with 3 Meter Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2661-52\u003c\/span\u003e\u003c\/span\u003e (087010MD) RDO Optical DO Probe with 3 Meter Cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-04\u003c\/span\u003e\u003c\/span\u003e (910410) Orion™ pH 4.01 Buffer, 10 pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-07\u003c\/span\u003e\u003c\/span\u003e (910710) Orion™ pH 7.00 Buffer, 10 pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-10\u003c\/span\u003e\u003c\/span\u003e (911010) Orion™ pH 10.01 Buffer, 10 pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2668-06\u003c\/span\u003e\u003c\/span\u003e (810001) Orion™ ROSS™ electrode storage solution, 475 mL\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e17-7109-06\u003c\/span\u003e\u003c\/span\u003e (01100710) Orion™ 1413 µS conductivity standard, 10 pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e21-2112-21\u003c\/span\u003e\u003c\/span\u003e (911110) rinse solution, 10 pouches\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2639-63\u003c\/span\u003e\u003c\/span\u003e (STARA-AR) protective armor with probe holders\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline; color: #0000ff;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2639-60\u003c\/span\u003e\u003c\/span\u003e (STARA-CS) hard carrying case\u003c\/li\u003e\n\u003cli\u003eFour AA batteries (installed)\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide\u003c\/li\u003e\n\u003cli\u003eLiterature CD\u003c\/li\u003e\n\u003cli\u003eUSB computer cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Barometer)\u003c\/td\u003e\n\u003ctd\u003e±6 mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit \u0026gt; 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (ISE)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (mV)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (pH)\u003c\/td\u003e\n\u003ctd\u003e±0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Polarographic DO)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mg\/L or ±2% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (RDO)\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L up to 8 mg\/L, ±0.2 mg\/L from 8 to 20 mg\/L, ±10% of reading up to 50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced ISE Functions\u003c\/td\u003e\n\u003ctd\u003eSegmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Correction\u003c\/td\u003e\n\u003ctd\u003e400 to 850 mm Hg, automatic using built-in barometer or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Modes\u003c\/td\u003e\n\u003ctd\u003eWater-saturated air, air-saturated water, manual (Winkler titration), zero point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (Conductivity)\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (ISE)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e5000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Range Polarographic DO\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.06 to 80.00 psu, 0.05 to 42.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.001 to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 3 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.01\/0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eBNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Range (Polarographic DO)\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Relative Accuracy (RDO)\u003c\/td\u003e\n\u003ctd\u003e±2 % saturation ≤ 200 % saturation, ±10 % saturation \u0026gt; 200 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Resolution (Polarographic DO)\u003c\/td\u003e\n\u003ctd\u003e0.1, 1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Range (RDO)\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Relative Accuracy (Polarographic DO)\u003c\/td\u003e\n\u003ctd\u003e±2 % saturation or ±2% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePercent Saturation Resolution (RDO)\u003c\/td\u003e\n\u003ctd\u003e0.1, 1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e400 to 850 mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange (ISE)\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19900 with selectable units of ppm, Molar, mg\/L, %, ppb or none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.001 μS minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Polarographic DO)\u003c\/td\u003e\n\u003ctd\u003e0.01, 0.1mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (RDO)\u003c\/td\u003e\n\u003ctd\u003e0.01, 0.1mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e1 ohm or 0.1 meg-ohm, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.01 psu or 0.01 ppt minimum, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Factor\u003c\/td\u003e\n\u003ctd\u003e0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Modes\u003c\/td\u003e\n\u003ctd\u003ePractical salinity (psu) or natural sea water (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor Range\u003c\/td\u003e\n\u003ctd\u003eLinear (0.02 to 9.99)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Metric) Reference\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C, 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51184556474683,"sku":"91-2639-45-EA","price":3630.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-45_e03d03ee-3b41-4258-9abf-3beb87ec3f70.png?v=1784707499","url":"https:\/\/preiser.com\/products\/orion-ph-ise-conductivity-dissolved-oxygen-portable-multiparameter-meter-kit-thermo-scientific-stara3295","provider":"Preiser Scientific","version":"1.0","type":"link"}