{"product_id":"orion-pro-star-ec212-conductivity-bench-meter-standard-kit-thermo-scientific-pstar2125","title":"Orion Pro Star EC212 Conductivity Bench Meter Standard Kit, Thermo Scientific, PSTAR2125","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Pro Star EC212 Conductivity Bench Meter Standard Kit, PSTAR2125\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: Conductivity, TDS, salinity or resistivity with temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConductivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 microS\/cm to 3000 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 microS\/cm minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e100.0 microS\/cm, 1413 microS\/cm, 12.88 mS\/cm, 111.9 mS\/cm or up to 4 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.100 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.475 cm\u003csup\u003e-1\u003c\/sup\u003e, 0.550 cm\u003csup\u003e-1\u003c\/sup\u003e, 1.000 cm\u003csup\u003e-1\u003c\/sup\u003e, 10.00 cm\u003csup\u003e-1\u003c\/sup\u003e or user-defined from 0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear (0.00 to 10.00 %\/ degrees C), nLFn (non-linear natural water), nLFu (non-linear ultra-pure water), EP\/USP or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25 or 30 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTDS\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 ppm to 500.0 ppt (TDS factor of 1.00); or 0.010 mg\/L to 500.0 g\/L (TDS factor of 1.00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm or mg\/L minimum, auto-ranging, up to 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppm to ppt; or mg\/L to g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003eLinear (0.01 to 10.00), ISO\/EN 27888, 442, NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSalinity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.010 to 80.00 ppt; 0.01 to 42.00 PSU; or 0.01 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppt minimum; 0.01 PSU minimum; or 0.01% NaCl minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd\u003eNatural Seawater (ppt), Practical Salinity Units (PSU), or % NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eResistivity\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1.0 ohms to 100.0 Mohs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ohms minimum, auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eConductivity, TDS, salinity or resistivity with temperature  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead Types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003e8-pin MiniDin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProStar EC212 Series Conductivity Meter\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable\u003c\/li\u003e\n\u003cli\u003e100-240V 50\/60Hz universal power adapter\u003c\/li\u003e\n\u003cli\u003eStand with Weighted Base\u003c\/li\u003e\n\u003cli\u003e4-cell epoxy\/graphite-body K=0.475 conductivity\/ATC electrode (013005MD)\u003c\/li\u003e\n\u003cli\u003e1413 μS\/cm conductivity standard pouches\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111037894971,"sku":"91-2640-14-EA","price":2180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-14_420fe661-8fdd-46b8-8eff-c49748815b83.png?v=1784707623","url":"https:\/\/preiser.com\/products\/orion-pro-star-ec212-conductivity-bench-meter-standard-kit-thermo-scientific-pstar2125","provider":"Preiser Scientific","version":"1.0","type":"link"}