{"product_id":"orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-ph-and-fluoride-kit-thermo-scientific-pstar2178","title":"Orion Pro Star PI217 Dual Channel pH\/Ion Bench Meter pH and Fluoride Kit, Thermo Scientific, PSTAR2178","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific (Trademark) Orion (Trademark) Dual Channel pH\/Ion Bench Meter pH and Fluoride Kit with Stand, PSTAR2178\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eParameters: pH, mV, ORP, temperature\u003c\/li\u003e\n\u003cli\u003eLarge 7-inch, high-resolution color display\u003c\/li\u003e\n\u003cli\u003eResponsive capacitive touchscreen operable with gloves\u003c\/li\u003e\n\u003cli\u003eAngled display to help ensure ergonomic viewing\u003c\/li\u003e\n\u003cli\u003eStreamlined, easy to operate user interface\u003c\/li\u003e\n\u003cli\u003eVertical meter orientation helps optimize bench space\u003c\/li\u003e\n\u003cli\u003eSupports GLP compliance\u003c\/li\u003e\n\u003cli\u003eSelect 1 to 5 point calibrations\u003c\/li\u003e\n\u003cli\u003eStores 20 calibration logs per parameter with date and time\u003c\/li\u003e\n\u003cli\u003eStores 10,000 data log sets with date and time\u003c\/li\u003e\n\u003cli\u003eOutputs to printer, computer, or USB flash drive for long-term data retention\u003c\/li\u003e\n\u003cli\u003eInputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse\u003c\/li\u003e\n\u003cli\u003eOptional meter-controlled and meter-powered stirrer probe\u003c\/li\u003e\n\u003cli\u003eStand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1, 0.01 or 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic buffer recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffer Sets\u003c\/td\u003e\n\u003ctd\u003eUSA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eRelative mV\/ORP\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or ±0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eORP or EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Offset\u003c\/td\u003e\n\u003ctd\u003e+\/-250 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIon\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 mV or +\/-0.05% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003eppt, ppm, ppb, mg\/L, M, mM, %, none or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic standard recognition, manual entry option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standards\u003c\/td\u003e\n\u003ctd\u003e1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope Type\u003c\/td\u003e\n\u003ctd\u003eLinear or segmented\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Summary\u003c\/td\u003e\n\u003ctd\u003eSlope and EO offset, option to view as point-to-point graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e1.000, user adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlank Correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Level Stability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncremental Techniques\u003c\/td\u003e\n\u003ctd\u003eSingle known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e–30.0 to 130.0 degrees C \/ –22.0 to 266.0 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 degrees C \/ 0.1 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.3 degrees C \/ +\/-0.5 degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOffset Adjustment\u003c\/td\u003e\n\u003ctd\u003eUp to 5.0 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Source\u003c\/td\u003e\n\u003ctd\u003eAutomatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeasurement Functions\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Parameters\u003c\/td\u003e\n\u003ctd\u003eChannel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRead types\u003c\/td\u003e\n\u003ctd\u003eContinuous, Auto-Read or Timed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimed Reading Intervals\u003c\/td\u003e\n\u003ctd\u003e3 seconds to 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Layout\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic, advanced or user-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic, fast, medium or slow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental or manual, up to 25 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraph\/Chart View\u003c\/td\u003e\n\u003ctd\u003eSingle parameter with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet Value Alarm\u003c\/td\u003e\n\u003ctd\u003e1 high and 1 low value per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLast Calibration Details\u003c\/td\u003e\n\u003ctd\u003eCalibration summary with date and time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eMeter Features\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch, high-resolution color graphic LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Type\u003c\/td\u003e\n\u003ctd\u003eCapacitive with lab glove compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnscreen Prompts\u003c\/td\u003e\n\u003ctd\u003eOn-demand information screens; onscreen user guide and step-by-step calibration guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime and Date\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Format\u003c\/td\u003e\n\u003ctd\u003e12 or 24 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eSelectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Name\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecure Mode\u003c\/td\u003e\n\u003ctd\u003e3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsername\u003c\/td\u003e\n\u003ctd\u003eUp to 20 alphanumeric characters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 (20 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003eUSB flash drive, computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output Format\u003c\/td\u003e\n\u003ctd\u003eCSV or print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log\u003c\/td\u003e\n\u003ctd\u003e10,000 data sets with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log\u003c\/td\u003e\n\u003ctd\u003e20 per parameter with time and date\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Log Export\u003c\/td\u003e\n\u003ctd\u003eCustomizable options for basic (short), intermediate, advanced or all data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003e1 alarm per parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Alarm Interval\u003c\/td\u003e\n\u003ctd\u003e1 hour to 30 days or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Signal\u003c\/td\u003e\n\u003ctd\u003eUser set for notifications and alarms, stable reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaintenance Reminder\u003c\/td\u003e\n\u003ctd\u003eUp to 5 electrode maintenance reminders and up to 5 solution maintenance reminders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSleep Mode\u003c\/td\u003e\n\u003ctd\u003eSelectable time interval of 5, 10, 20, 30, 60 minutes or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter tests\u003c\/td\u003e\n\u003ctd\u003eSelf-test, stability test and pH electrode check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter Tour and Guides\u003c\/td\u003e\n\u003ctd\u003eCalibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Inputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Probe Speeds\u003c\/td\u003e\n\u003ctd\u003e5 selectable speeds from 250 RPM to 3600 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Inputs\u003c\/td\u003e\n\u003ctd\u003eChannel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Outputs\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory Input\u003c\/td\u003e\n\u003ctd\u003e1 USB-A port for USB mouse, USB keyboard or USB barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile, to preserve data and settings in case of power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Languages\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePro Star PD217 Dual Channel pH\/Ion and DO Bench Meter\u003c\/li\u003e\n\u003cli\u003eStand with weighted base\u003c\/li\u003e\n\u003cli\u003eUSB flash drive\u003c\/li\u003e\n\u003cli\u003eComputer cable, 100-240V 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eUniversal power adapter (purchase electrodes separately)\u003c\/li\u003e\n\u003cli\u003eROSS Ultra Triode refillable epoxy-body pH\/ATC electrode (8157BNUMD)\u003c\/li\u003e\n\u003cli\u003eFluoride ion selective electrode (9609BNWP)\u003c\/li\u003e\n\u003cli\u003eStirrer probe (096019-WA)\u003c\/li\u003e\n\u003cli\u003epH 4, 7, 10 buffers and rinse solution pouches\u003c\/li\u003e\n\u003cli\u003epH electrode storage solution\u003c\/li\u003e\n\u003cli\u003eCleaning solution\u003c\/li\u003e\n\u003cli\u003epH electrode storage sleeve\u003c\/li\u003e\n\u003cli\u003eFluoride 100 ppm standard\u003c\/li\u003e\n\u003cli\u003eFluoride 0.5, 1 and 5 ppm standards premixed with TISAB II\u003c\/li\u003e\n\u003cli\u003eTISAB II solution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111039500603,"sku":"91-2640-59-EA","price":3900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2640-59_6dacdac6-8e7c-402c-b9a9-56978058c982.png?v=1784707695","url":"https:\/\/preiser.com\/products\/orion-pro-star-pi217-dual-channel-ph-ion-bench-meter-ph-and-fluoride-kit-thermo-scientific-pstar2178","provider":"Preiser Scientific","version":"1.0","type":"link"}