{"product_id":"orion-star-a215-ph-conductivity-benchtop-meter-with-stand-stara2150","title":"Orion Star A215 pH\/Conductivity Benchtop Meter with Stand, STARA2150","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion™ Star™ A215 pH\/Conductivity Benchtop Meter; Orion™ ROSS Ultra™ Triode™ Refillable, Epoxy-Body pH\/ATC Electrode; Orion™ DuraProbe™ Conductivity Probe; ROSS™ pH Buffer and Solution Kit; Orion™ 1413 μS Conductivity Standard, STARA2155\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecord accurate and reliable pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature measurements with easy-to-use, reliable multiparameter meter\u003c\/li\u003e\n\u003cli\u003eIdeal for wide range of applications and advanced pH and conductivity analysis in lab\u003c\/li\u003e\n\u003cli\u003eTwo meter channels to measure pH and conductivity simultaneously or view each channel separately by a simple toggle\u003c\/li\u003e\n\u003cli\u003ePerform up to 5 point calibration, log up to 2000 data point sets with time\/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer\u003c\/li\u003e\n\u003cli\u003eSelectable read modes and stability indicator gives flexibility and control over testing\u003c\/li\u003e\n\u003cli\u003eAll critical data is shown including temperature, date and time, read type, measurement stability, active calibration information and electrode condition icon\u003c\/li\u003e\n\u003cli\u003eOnscreen calibration and setup instructions can be displayed in several local languages with new languages added through software updates\u003c\/li\u003e\n\u003cli\u003eFast and simple navigation due to comprehensive keypad with menu-specific function keys, dual purpose scroll\/shortcut keys, plus power, measure, log view and stirrer keys that ensure easy operation\u003c\/li\u003e\n\u003cli\u003eDirect access to all setup menus in one location using single shortcut key to allow user to quickly access, evaluate and change measurement and instrument settings.\u003c\/li\u003e\n\u003cli\u003eCombined convenience with the benefits of a pH meter and conductivity meter in one easy-to-use system\u003c\/li\u003e\n\u003cli\u003eCalibration editing option allows individual points to be fixed without a full recalibration\u003c\/li\u003e\n\u003cli\u003eAuto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate\u003c\/li\u003e\n\u003cli\u003eUse linear, non-linear, EP (USP) or off conductivity temperature compensation with 5 °C, 10 °C, 15 °C, 20 °C or 25 °C reference temperatures\u003c\/li\u003e\n\u003cli\u003eCapture critical readings with measurement stability indicator and selectable read modes — \u003cem\u003eAuto-Read\u003c\/em\u003e holds a stable reading, \u003cem\u003eContinuous\u003c\/em\u003e shows changing readings with hold option and \u003cem\u003eTimed\u003c\/em\u003e logs data at specific intervals\u003c\/li\u003e\n\u003cli\u003eEliminate the need for magnetic stir bars using the meter-controlled stirrer probe \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003eORN-096019\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 096019) to uniformly mix solutions (purchase separately)\u003c\/li\u003e\n\u003cli\u003eData log collects and date\/time stamps up to 2000 measurement sets with optional sample ID and user ID\u003c\/li\u003e\n\u003cli\u003eCalibration log stores 10 most recent calibrations\u003c\/li\u003e\n\u003cli\u003eNon-volatile meter memory ensures your data and settings are protected, even with loss of power\u003c\/li\u003e\n\u003cli\u003eOrion™ Star Com™ software facilitates data transfer to a computer via USB or RS232 connections\u003c\/li\u003e\n\u003cli\u003eIP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStar A215 pH\/Conductivity Benchtop Meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2639-61\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ STARA-BEA) Attached electrode stand and holder\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e\u003cspan style=\"color: #0000ff; text-decoration: underline;\"\u003e91-2639-68\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e (Orion™ 1010003) Universal power adapter\u003c\/li\u003e\n\u003cli\u003ePrinted quick start guide and literature CD\u003c\/li\u003e\n\u003cli\u003eUSB computer cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit \u0026gt; 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (mV)\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV or ±0.05% of reading whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (pH)\u003c\/td\u003e\n\u003ctd\u003e±0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eHigh\/low limit alarm, calibration due alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight Option\u003c\/td\u003e\n\u003ctd\u003eYes, selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e800 hr.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003epH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e1 point relative mV (RmV) mode, 1 point ORP mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (Conductivity)\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points (pH)\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e0.001 to 199.9 cm\u003csup\u003e-1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Management Details\u003c\/td\u003e\n\u003ctd\u003eTransfer single, range or all data points to printer or computer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points\u003c\/td\u003e\n\u003ctd\u003e2000 with date and time stamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD Graphic, Backlit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP 54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003epH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (pH)\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential Point\u003c\/td\u003e\n\u003ctd\u003e7.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003eComprehensive with menu-specific function keys and dual purpose scroll\/shortcut keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Function Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data log, calibration log and meter settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethods\u003c\/td\u003e\n\u003ctd\u003e10 per channel with password protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Conductivity)\u003c\/td\u003e\n\u003ctd\u003e0.001 μS minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (mV)\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Resistivity)\u003c\/td\u003e\n\u003ctd\u003e1 ohm or 0.1 meg-ohm, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (Salinity)\u003c\/td\u003e\n\u003ctd\u003e0.01 psu or 0.01 ppt minimum, auto ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (TDS)\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm minimum, auto ranging up to 4 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Modes\u003c\/td\u003e\n\u003ctd\u003ePractical salinity (psu) or natural sea water (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003eSelectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor Range\u003c\/td\u003e\n\u003ctd\u003eLinear (0.02 to 9.99)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature (Metric) Reference\u003c\/td\u003e\n\u003ctd\u003e5, 10, 15, 20, 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point temperature offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Selection\u003c\/td\u003e\n\u003ctd\u003eManual or automatic with ATC temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111035601211,"sku":"91-2639-18-EA","price":2140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2639-18_d284c3ef-e450-4449-a525-60733d8b964e.png?v=1784707444","url":"https:\/\/preiser.com\/products\/orion-star-a215-ph-conductivity-benchtop-meter-with-stand-stara2150","provider":"Preiser Scientific","version":"1.0","type":"link"}