{"product_id":"orion-star-t930-ion-titrator-chloride-salt-kit-thermo-scientific-start9301","title":"Orion Star T930 Ion Titrator Chloride\/Salt Kit, Thermo Scientific, START9301","description":"\u003cp\u003e\u003cstrong\u003eThermo Scientific™ Orion® Star T930 Ion Titrator with Salt Content Kit, START9300\u003c\/strong\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for dedicated titrations\u003c\/li\u003e\n\u003cli\u003eTitration techniques include equivalence point titrations and preset mV endpoint titrations plus multiple known addition (MKA) mode which the titration is performed by a calculation of sample concentration by adding aliquots of standard to sample, removing the need for a separate calibration and minimizing matix effects\u003c\/li\u003e\n\u003cli\u003eCompatible with any premium Orion® ion selective electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSalts in foods\u003c\/li\u003e\n\u003cli\u003eChloride in drinking and wastewater\u003c\/li\u003e\n\u003cli\u003eAmmonia and Total Kjeldahl Nitrogen (TKN) in wastewater\u003c\/li\u003e\n\u003cli\u003eSurfactants in consumer products\u003c\/li\u003e\n\u003cli\u003eTotal hardness in water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e9780SC silver billet electrode,\u003c\/li\u003e\n\u003cli\u003e91CBNC electrode cable\u003c\/li\u003e\n\u003cli\u003e20 mL burette\u003c\/li\u003e\n\u003cli\u003eStirrer probe\u003c\/li\u003e\n\u003cli\u003eDispenser probe\u003c\/li\u003e\n\u003cli\u003eStandard tubing kit\u003c\/li\u003e\n\u003cli\u003e1 L plastic reagent bottle\u003c\/li\u003e\n\u003cli\u003eGL38 bottle cap with two ports\u003c\/li\u003e\n\u003cli\u003eDesiccant tube\u003c\/li\u003e\n\u003cli\u003eComputer cable\u003c\/li\u003e\n\u003cli\u003eManual on USB drive\u003c\/li\u003e\n\u003cli\u003e110-240 V power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"\" frame=\"\" rules=\"\" align=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIon titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrion® Star T930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5% RSD, dependent on environment and handling conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurette drive offers advanced micro-step technology that provides25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIon concentration (ISE) and temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Range  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 85%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to +2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0001 to 19990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0001 minimum, 1 to 4 significant digits (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.2 mV or ± 0.05% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 100.0 °C (23.0 to 212.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 40 °C (41 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eOptional 1 point offset calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNotifications for titration cycle complete, maximum titrant volume, data log full, calibration due, maintenance reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBacklight Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 data sets each:  sample titration, titrant standardization, calibration, and direct measure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Management Details \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData log export as CSV or PDF file, short or long format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Techniques\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquivalence point or preset endpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquivalence Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreset Endpoints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect or back titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlank Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed value or variable value using titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycles per Titration Run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5 cycles, option to exclude cycle results from average results and RSD calculations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitrant Determination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandardization titration or manual concentration input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Process Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoutine, quick, careful, or user defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStirrer Probe Speeds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 user seletable speeds (250 to 3700 RPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto-incremental, manual, or off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Setup Wizard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, using \"\"Start a New Titration\"\" workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdateable Firmware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, using USB flash drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurette Sizes Accepted \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mL, 20 mL (included with instrument), 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurette Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds accuracy requirements of ISO8655-3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitrator Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.7\"\" color capacitive touchscreen, 640 x 480 resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 x 40.6 x 35.6 cm (10\"\" x 16\"\" x 14\"\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctions Available\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSample titration, titrant standardization, calibration, and direct measure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBNC (ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 USB ports for printer, USB flash drive, and computer softwareconnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Types \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIon selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-volatile memory preserves data logs and settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 10 methods with optional password protection; import\/export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChinese, English, French, German, Italian, Japanese, Korean, Portuguese, and Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\/Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, TUV 3-in-1, FCC, EN\/EIC61326-1, IEC 61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V, 50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime and Date\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, with nonvolatile battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cstrong\u003eTitrator Accessories:\u003c\/strong\u003e\u003ctable frame=\"border\" rules=\"all\" style=\"border-color: #000000; border-width: 1px;\" border=\"1\" align=\"center\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-10\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eBurette Cover\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-11\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e10 mL Burette\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-12\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e20 mL Burette\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-13\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e50 mL Burette\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-14\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eReagent Bottle Holder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e92-2471-15 \u003c\/span\u003e  \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 L Plastic Reagent Bottle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-16\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 L Glass Amber Reagent Bottle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-17\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 L Plastic Reagent Bottle, 12\/PK\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-18\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 L Glass Amber Reagent Bottle, 12\/PK    \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e92-2471-19\u003c\/span\u003e    \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eGL38 Reagent Bottle Cap\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-20\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eGL45 Reagent Bottle Cap\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-21\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDispenser Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-22\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDispense Verify Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-23\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eElectrode Holder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-24\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eStopper for Electrode Holder\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-25\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCable Management System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-26\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e110 V US Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-27\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eStandard Tubing Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-28\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eLight Blocking Tubing Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-29\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eDrying Tube\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-30\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eTubing w\/Blue Fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-31\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eTubing w\/White Fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-32\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eTubing w\/Black Fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-33\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUser Manual w\/USB Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-34\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUSB Computer Cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan style=\"font-size: small;\"\u003e92-2471-35\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eReplacement Valve Kit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Thermo Fisher Scientific","offers":[{"title":"EA (1)","offer_id":51111213302075,"sku":"92-2471-07-EA","price":5540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2471-07.png?v=1784712083","url":"https:\/\/preiser.com\/products\/orion-star-t930-ion-titrator-chloride-salt-kit-thermo-scientific-start9301","provider":"Preiser Scientific","version":"1.0","type":"link"}