{"product_id":"ph-electrode-atc-titanium-body-polymer-filled-double-junction-1-m-cable-bnc-phono-connector-for-boilers-cooling-towers-hanna-instruments-hi72911b","title":"pH Electrode\/ATC, Titanium Body, Polymer Filled, Double Junction, 1 m Cable, \u0026 BNC + Phono Connector for Boilers\/Cooling Towers, Hanna Instruments, HI72911B","description":"\u003cp\u003e\u003cstrong\u003eHanna Instruments® pH Electrode\/ATC, Titanium Body, Polymer Filled, Double Junction, 1 m Cable, \u0026amp; BNC + Phono Connector for Boilers\/Cooling Towers, HI72911B\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003epH electrode with built-in temperature sensor and double junction\u003c\/li\u003e \u003cli\u003eDesigned using general purpose (GP) glass, flat tip bulb, titanium body, and PTFE junction with polymer electrolyte\u003c\/li\u003e \u003cli\u003eRecessed flat tip is easy to clean and prevents solids in solutions from collecting on sensor\u003c\/li\u003e \u003cli\u003eTitanium body increases immunity to electrostatic and magnetic fields and is strongly corrosive resistant\u003c\/li\u003e \u003cli\u003eAlso serves as a matching pin for safe, precise pH measurements\u003c\/li\u003e \u003cli\u003ePTFE junction often used on electrodes with polymer electrolytes and because of its chemical advantages is widely used in industrial applications\u003c\/li\u003e \u003cli\u003eDouble junction offers distinct advantages when used under adverse conditions\u003c\/li\u003e \u003cli\u003eOnly one junction is in contact with the sample\u003c\/li\u003e \u003cli\u003eTendency of sample ingress and contamination of the electrode is minimized by this system\u003c\/li\u003e \u003cli\u003eLikelihood of clogging of junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is silver-free\u003c\/li\u003e \u003cli\u003eSince there is no silver present, there is no precipitate that can form to clog junction\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e \u003ctable style=\"width:\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003edouble, Ag\/AgCl\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eJunction \/ Flow Rate\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePTFE\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003epolymer\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e3 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003epH: 0 to 13\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0 to 80 °C (32 to 176 °F) - GP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTip \/ Shape\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eflat\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Sensor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eyes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eyes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e7-pole; 1 m (3.3 ft.)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ecooling towers, boilers\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eB BNC + phono†\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSpecial Note\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e† Recommended for use with HI98191 (\u003cspan\u003e\u003cspan style=\"text-decoration:\" underline color:\u003e91-2599-43\u003c\/span\u003e\u003c\/span\u003e) pH meter\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111023280443,"sku":"91-2599-38-EA","price":249.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2599-38_b7f49417-da3e-4664-897a-d87893cc0872.png?v=1784707033","url":"https:\/\/preiser.com\/products\/ph-electrode-atc-titanium-body-polymer-filled-double-junction-1-m-cable-bnc-phono-connector-for-boilers-cooling-towers-hanna-instruments-hi72911b","provider":"Preiser Scientific","version":"1.0","type":"link"}