{"product_id":"ph-mv-meter-research-grade-benchtop-with-probes-0-001-ph-resolution-hanna-instruments-hi5221-01","title":"pH\/mV Meter, Research Grade Benchtop with Probes, 0.001 pH Resolution, Hanna Instruments, HI5221-01","description":"\u003cp\u003e\u003c\/p\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eHanna® Laboratory Research Grade Benchtop pH\/mV Meter with pH Electrode and Temperature Probe, 0.001 pH Resolution\u003c\/span\u003e\u003c\/strong\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:\" small\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eHighly customizable user interface\u003c\/strong\u003e—includes showing measurements in various modes with or without GLP information, real-time graphing, logging data, adjustable calibration stability criteria (fast, moderate, and accurate), programmable alarm limits (inside or outside)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eColor graphic LCD\u003c\/strong\u003e—on-screen help, graphic and custom color configurations, real-time graphing, virtual keys for intuitive user interface\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eBuilt in barometer\u003c\/strong\u003e—provides pressure compensation for all DO measurements via built-in pressure transducer (can be calibrate to a single point)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eCapacitive touch\u003c\/strong\u003e—sensitive touch buttons for accurate keystrokes while navigating menus and screens; four dedicated keys for routine operations including calibration and switching modes plus four virtual keys that change based on use; no worry of clogged buttons \u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eChoice of calibration\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options available for calibrating up to 5 points from a selection of 8 standard buffers and up to 5 custom buffers\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—user can view calibration data and calibration expiration at touch of a key; includes date, time, buffer\/standards used, and slope characteristcs; offset for pH electrodes also displayed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eCAL Check™—\u003c\/strong\u003ealerts user to potential problems during calibration of pH electrode; indicators include Electrode Dirty\/Broken, Buffer Contaminated, electrode response time and overall probe condition as a percentage based on offset and slope \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eData logging\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e—automatic, manual, and auto-hold logging \u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e(up to 100 lots with 50,000 records maximum\/lot, with up to 100,000 total data points)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e ; automatic logging features option to save data according to sampling period and interval\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eData transfer\u003c\/strong\u003e—transfer data to PC via USB cable and HI92000 software (sold separately)\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eContextual help\u003c\/strong\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e—\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003ededicated Help key provides clear tutorial messages and on-screen directions to guide users through set-up and calibration; information displayed relative to setting or option being viewed\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e—2 years for meter; 6 months for probes\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003c\/p\u003e\u003cspan style=\"font-size:\" small\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e \u003cp\u003e \u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI1131B pH electrode (\u003cspan\u003e91-2698-24\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI7662-T temperature probe (\u003cspan\u003e91-5990-12\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI76404W electrode holder\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI70004P pH 4.01 buffer solution sachet (\u003cspan\u003e91-2704-04\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI70007P pH 7.01 buffer solution sachet (\u003cspan\u003e91-2704-07\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e\u003cspan style=\"font-size:\" small\u003eHI70000P electrode cleaning solution sachet (2) (\u003cspan\u003e91-2704-11\u003c\/span\u003e)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eHI7082 3.5M KCl electrolyte solution (30 mL) (\u003cspan\u003e91-2599-79\u003c\/span\u003e)\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003e12 VDC adapter\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-size:\" small\u003eInstruction Manual\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003cdiv style=\"text-align:\" center\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/div\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 579px; height: 719px; border: 1px solid #0d026d;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #a3adac;\" rowspan=\"5\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003e- 2.0 to 20.0 pH; - 2.00 to 20.00 pH; - 2.000 to 20.000 pH\u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1; 0.01; 0.001 pH\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy @ 25 \u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e (77 \u003cspan style=\"font-size: small;\"\u003e°F)\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.1 pH; ± 0.01 pH; \u003cspan style=\"font-size: small;\"\u003e± 0.002 pH \u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 1 LSD\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eAutomatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature compensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-size: small;\"\u003eAutomatic or manual from - 20 to 120.0 \u003c\/span\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e°C\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #a3adac;\" rowspan=\"4\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003emV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 2000 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 mV\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.2 mV \u003cspan style=\"font-size: small;\"\u003e±\u003c\/span\u003e 1 LSD\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRelative offset range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e± 2000 mV\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #a3adac;\" rowspan=\"3\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature  \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eRange\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e- 20.0 to 120 °C; - 4.0 to 248 °F; 253.15 to 393.1 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e± 0.2 °C; ± 0.4 °F; ± 0.2 K \u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #05002c; border: 1px solid #a3adac;\" rowspan=\"11\"\u003e\n\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eAdditional \u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eElectrode\/Probe\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eHI1131B glass body pH electrode with BNC connector and 1 m (3.3') cable (included)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature probe\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eHI7662-T stainless steel temperature probe with 1 m (3.3') cable (included)\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eGLP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eCalibration data including date, time, buffers used, offset, and slope\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eLogging \u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e100,000 records storage, 100 lots with 50,000 records\/lot; \u003cbr\u003eInterval: settlable between 1 second and 180 minutes maximum log time; \u003cbr\u003eType: automatic, manual, AutoHold\u003cbr\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eInput channels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e1 - pH\/ORP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eEnvironment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50 \u003cspan style=\"font-size: small;\"\u003e°C (32 to 122 \u003cspan style=\"font-size: small;\"\u003e°F; 273 to 323 K);\u003cbr\u003eRelative Humidity Maximum 95% non-condensing\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePC connectvity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003eUSB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003eColor graphic LCD with on-screen help, graphing, and custom color configuation\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003ePower supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e12 VDC adapter (included)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e160 x 231 x 94 mm (6.3 x 9.1 x 3.7\")\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cstrong\u003e\u003cspan style=\"font-size: small;\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"font-size: small;\"\u003e1.2 kg (2.64 lbs.)\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cbr\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e \u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e \u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e \u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111024558395,"sku":"91-2599-90-EA","price":880.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/91-2599-90_e6625b45-e3c3-40b4-b559-29256b13962a.png?v=1784707078","url":"https:\/\/preiser.com\/products\/ph-mv-meter-research-grade-benchtop-with-probes-0-001-ph-resolution-hanna-instruments-hi5221-01","provider":"Preiser Scientific","version":"1.0","type":"link"}