{"product_id":"pp-quatro-4-p-ph-orp-handheld-meter-kit-ysi-606967","title":"PP Quatro-4 P pH\/ORP Handheld Meter Kit, YSI, 606967","description":"\u003cp\u003e\u003cstrong\u003eYSI Inc.® PP Quatro-4 P pH\/ORP Handheld Meter Kit, 606967\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProQuatro handheld multiparameter meter measures a variety of combinations of dissolved oxygen, conductivity, specific conductance, salinity, resistivity, total dissolved solids (TDS), pH, ORP, pH\/ORP combination, ammonium (ammonia), nitrate, chloride and temperature\u003c\/li\u003e\n\u003cli\u003eUser–replaceable cables and sensors\u003c\/li\u003e\n\u003cli\u003eReal-time salinity compensation of DO measurements\u003c\/li\u003e\n\u003cli\u003eQuick response times\u003c\/li\u003e\n\u003cli\u003eImpact-resistant, waterproof case\u003c\/li\u003e\n\u003cli\u003eBuilt-in micro USB port for simplified access to your data in field or lab\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProQuatro handheld\u003c\/li\u003e\n\u003cli\u003e605790- 4 ISE\/ISE\/DO\/Cond\/Temp cable\u003c\/li\u003e\n\u003cli\u003e605101 - pH sensor\u003c\/li\u003e\n\u003cli\u003e605203 - polarographic DO sensor\u003c\/li\u003e\n\u003cli\u003e603075 - soft-sided carrying case\u003c\/li\u003e\n\u003cli\u003e605102 - ORP sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight; USB power or optional wall power can be supplied via\u003cbr\u003emicro USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output\u003c\/td\u003e\n\u003ctd\u003eBuilt-in micro USB port for on-the-go data exports via direct connection to the included USB stick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Updates\u003c\/td\u003e\n\u003ctd\u003eUser-upgradeable firmware via USB and website\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e5000 datasets; 50 unique data identifiers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Modes\u003c\/td\u003e\n\u003ctd\u003eSingle point or continuous with auto stable feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoice of Cables Available\u003c\/td\u003e\n\u003ctd\u003eField Cables Standard lengths of 1, 4, 10, 20 or 30 meters with single port, dual port or Quatro cables; Lab Cables BOD sensor includes 2-meter cable; 1 or 4 meters on lab pH, ORP and pH\/ORP cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Units (with Glass Combination Electrode) Units\u003c\/td\u003e\n\u003ctd\u003emV, pH units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e1, 2, or 3 point (user selectable); US, NIST or Custom Buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP (Platinum Button) Units\u003c\/td\u003e\n\u003ctd\u003emV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen (Polarographic or Galvanic) @ -5 to 50 °C Temperature Compensation Range Units:\u003c\/td\u003e\n\u003ctd\u003e% Saturation; mg\/L, ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen (Polarographic or Galvanic) @ -5 to 50 °C\u003c\/td\u003e\n\u003ctd\u003e0 to 500% Saturation; 0 to 50 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% or 1% air saturation\u003cbr\u003e(user selectable); 0.1% air saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e0 to 200%: ±2% of reading or 2% air saturation, w.i.g. 200 to 500%: ±6% of reading; 0 to 20 mg\/L: ±2% of reading or 0.2 mg\/L, w.i.g. 20 to 50 mg\/L: ±6% of reading 0.1% or 0.01 mg\/L (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point with zero\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Membrane Response Times (T95; 100%-0) and Flow Dependence\u003c\/td\u003e\n\u003ctd\u003e1.25 mil PE = 8 seconds and 6 in\/sec flow\u003cbr\u003e2.0 mil PE = 17 seconds and 3 in\/sec flow\u003cbr\u003e1 mil Teflon® = 18 seconds and 12 in\/sec flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity \/ Specific Conductance (Four Electrode Cell) Units\u003c\/td\u003e\n\u003ctd\u003eμS, mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm (auto-range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 m, 4 m cables: Range dependent; 20 m cable: 0 to 0.500 mS\/cm: 0.001 0.501 to 50.00 mS\/cm: 0.01 50.01 to 200 mS\/cm: 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e1 m, 4 m cables: ±0.5% of reading or 0.001 mS\/cm, w.i.g.; 20 m cable: ±1% of reading or 0.001 mS\/cm, w.i.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Units\u003c\/td\u003e\n\u003ctd\u003eppt, PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0% of reading or ±0.1 ppt, w.i.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) (Calculated) Units\u003c\/td\u003e\n\u003ctd\u003emg\/L, kg\/L, g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 g\/L; TDS constant range\u003cbr\u003e0.3 to 1.0 (0.65 default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, .01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids Accuracy\u003c\/td\u003e\n\u003ctd\u003eNo stated accuracy spec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity (Calculated) Units\u003c\/td\u003e\n\u003ctd\u003eohm-cm, kohm-cm, Mohm-cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2 Mohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, 0.1 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium* (Ion Selective Electrode) Units:\u003c\/td\u003e\n\u003ctd\u003emg\/L-N, mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mg\/L-N\u003cbr\u003e0 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% of reading or 2 mg\/L-N, w.i.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Calibration\u003c\/td\u003e\n\u003ctd\u003e1, 2, or 3 point (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride* (Ion Selective Electrode) Units\u003c\/td\u003e\n\u003ctd\u003emg\/L-Cl-, mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 mg\/L\u003cbr\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±15% of reading or 5 mg\/L, w.i.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Calibration\u003c\/td\u003e\n\u003ctd\u003e1, 2, or 3 point (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate* (Ion Selective Electrode) Units \u003c\/td\u003e\n\u003ctd\u003emg\/L-N, mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mg\/L-N 0 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% of reading or 2 mg\/L-N, w.i.g.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Calibration\u003c\/td\u003e\n\u003ctd\u003e1, 2, or 3 point (user selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Units\u003c\/td\u003e\n\u003ctd\u003eConductivity \/ Specific Conductance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003eField Cables: 0.1 °C\u003cbr\u003eLab Cables: 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003eField Cables: ±0.2 °C; ±0.3 °C cables over 45 m; Lab Cables: ±0.35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mm Hg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 mm Hg from 0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaterproof\u003c\/td\u003e\n\u003ctd\u003eIP-67 (even with battery cover off); floats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Chinese (Simplified \u0026amp; Traditional), French, German, Italian, Japanese, Norwegian, Portuguese, Spanish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eAssembled in the US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51110928122171,"sku":"90-6400-113-EA","price":4301.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/90-6400-113.png?v=1784704758","url":"https:\/\/preiser.com\/products\/pp-quatro-4-p-ph-orp-handheld-meter-kit-ysi-606967","provider":"Preiser Scientific","version":"1.0","type":"link"}