{"product_id":"syringe-model-702-n-25-microliter-hamilton-80400","title":"Syringe Model 702 N 25 microliter, Hamilton, 80400","description":"\u003cp\u003e\u003cstrong\u003eSyringe Model 702 N 25 microliter, Hamilton, 80400\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe 700 series syringe — original hand-fitted Hamilton syringe\u003c\/li\u003e\n\u003cli\u003eNeedles cemented into glass syringe barrel at point corresponding to zero graduation mark\u003c\/li\u003e\n\u003cli\u003eWith this termination, dead volume is limited to internal volume of needle\u003c\/li\u003e\n\u003cli\u003eNot autoclavable\u003c\/li\u003e\n\u003cli\u003eNeedle gauge is determined by syringe volume and is not user-selectable\u003c\/li\u003e\n\u003cli\u003eStainless steel plunger is manufactured to fit glass barrel with tolerance smaller than 100 millionths of inch, resulting in unsurpassed syringe life.\u003c\/li\u003e\n\u003cli\u003eIdeal for dispensing volumes from 0.5 – 500µL\u003c\/li\u003e\n\u003cli\u003eEach syringe manufactured to achieve highest level of accuracy and precision possible\u003c\/li\u003e\n\u003cli\u003eFluid path is SST and borosilicate glass\u003c\/li\u003e\n\u003cli\u003eVariety of different terminations and needle options available\n\u003cul\u003e\n\u003cli\u003eNeedle Point style 2 is a sharp, beveled, curved, non-coring needle point recommended for septum penetration\u003c\/li\u003e\n\u003cli\u003ePoint style 3 is a blunt needle point for use with HPLC injection valves and sample pipetting\u003c\/li\u003e\n\u003cli\u003ePoint style 5 is a conical needle with side port for penetration of septa, thin-gauged vinyls, and plastics without coring\u003c\/li\u003e\n\u003cli\u003ePoint Style AS is a special conical style needle point used on autosampler syringes\u003c\/li\u003e\n\u003cli\u003eNon-coring needle point recommended for septum penetration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 85%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume\u003c\/td\u003e\n\u003ctd\u003e25 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe Type\u003c\/td\u003e\n\u003ctd\u003eMicroliter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe Series\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003eCemented Needle (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle\u003c\/td\u003e\n\u003ctd\u003eCemented Needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGauge\u003c\/td\u003e\n\u003ctd\u003e22s gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoint Style\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Length\u003c\/td\u003e\n\u003ctd\u003e2 inch (51 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid Path\u003c\/td\u003e\n\u003ctd\u003eSST, borosilicate glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoclavable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Sterilizable\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003e2000 psig (137.9 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd\u003e50°C \/ 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Temperature\u003c\/td\u003e\n\u003ctd\u003e10°C \/ 50°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel Inner Diameter\u003c\/td\u003e\n\u003ctd\u003e0.029 inches (0.729 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e0.305 inches (7.75 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Inner Diameter\u003c\/td\u003e\n\u003ctd\u003e0.0059 inches (0.15 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e0.0283 inches (0.72 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStd Needle Dead Volume\u003c\/td\u003e\n\u003ctd\u003e1.13 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Others","offers":[{"title":"EA (1)","offer_id":51110690586939,"sku":"14-4200-05-EA","price":74.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/14-4200-05_51903fdc-26b5-487d-94fa-948c5008ddb2.png?v=1784698827","url":"https:\/\/preiser.com\/products\/syringe-model-702-n-25-microliter-hamilton-80400","provider":"Preiser Scientific","version":"1.0","type":"link"}