{"product_id":"turbidity-meter-kit-portable-logging-iso-compliant-for-field-measurements-hanna-instruments-hi93703c","title":"Turbidity Meter Kit, Portable, Logging ISO Compliant, for Field Measurements, Hanna Instruments, HI93703C","description":"\u003cp\u003e\u003c\/p\u003e\u003cspan style=\"font-family:\" times new roman small font-size:=\"\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e \u003cp\u003e \u003c\/p\u003e \u003cul style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eGLP Features\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e3 point calibration\u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eTwo-year warranty\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e \u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.\u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/span\u003e\u003c\/p\u003e \u003cp style=\"color:\" tahoma arial freesans helvetica sans-serif normal auto start none font-family:=\"\" font-size:=\"\" font-style:=\"\" font-variant:=\"\" font-weight:=\"\" letter-spacing:=\"\" line-height:=\"\" orphans:=\"\" text-align:=\"\" text-indent:=\"\" text-transform:=\"\" white-space:=\"\" widows:=\"\" word-spacing:=\"\" background-color:=\"\"\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003eHANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination. HI 93703 can be used with both standards.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family:\" times new roman font-size: small\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"spec_table\" style=\"color: #000000; font-family: Tahoma,Arial,FreeSans,Helvetica,sans-serif; font-size: 12px; font-style: normal; font-variant: normal; font-weight: normal; letter-spacing: normal; line-height: 18px; text-align: start; text-indent: 0px; text-transform: none; white-space: normal; word-spacing: 0px; width: 75%; border: 1px solid #000000;\" border=\"1\" frame=\"border\" rules=\"all\" align=\"center\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.00 to 50.00 FTU;\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e50 to 1000 FTU\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0.01 FTU (0.00 to 50.00 FTU);\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e1 FTU (50 to 1000 FTU)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e3 points (0 FTU, 10 FTU and 500 FTU)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003einfrared LED\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eLight Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eSilicon Photocell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background-color: #c3dffc;\"\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e510 g (1.1 lb.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003e\u003cstrong\u003eSupplied with:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703 Turbidity Meter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eGlass Cuvette\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eBatteries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eInstructions\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eMaintenance Kit which includes:\u003c\/span\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eRugged carrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703-0 Calibration Solution (0 FTU Solution)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93102-10 Calibration Solution (10 FTU Solution)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eHI 93703-50 Cuvette Cleaning Solution\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eCuvettes (2)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"font-family: times new roman,times; font-size: small;\"\u003eCuvette Cleaning Cloth\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"EA (1)","offer_id":51111210713403,"sku":"92-2450-27-EA","price":1299.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0921\/2041\/6571\/files\/92-2450-27.png?v=1784711980","url":"https:\/\/preiser.com\/products\/turbidity-meter-kit-portable-logging-iso-compliant-for-field-measurements-hanna-instruments-hi93703c","provider":"Preiser Scientific","version":"1.0","type":"link"}