Description
Hanna Instruments® Colorimeter, High Range Ammonia Checker® HC, 0.0 to 99.9 ppm, HI733
Features:
- Handheld colorimeter is simple, accurate, and cost effective way to measure high ranges of ammonia in fresh water
- Present in water as a component of nitrogen cycle, ammonia is excreted from animals and other organisms such as heterotrophic bacteria, actinomycetes, and fungi during the metabolism of proteins and amino acids
- Generally present in small quantities in unpolluted waters, higher levels indicate organic pollution and is toxic to aquatic life
- Designed as a more accurate alternative to chemical test kits and it provides quick, accurate results in four easy steps:
- Step One - Add 1 mL of sample and 9 mL of reagent B to the included cuvette(s)
- Step Two - Insert sample into the Checker®HC and zero it out
- Step Three - Remove sample and add reagent A
- Step Four - Reinsert sample and click the button to measure your results or . . . Press and hold the button for 3 seconds for a time reaction reading
- The Checker®HC Ammonia colorimeter uses an adaption of the ASTM Manual of Water and Enviornmental Technology, D1426-92 Nessler method
- Reaction between ammonia and the reagents causes a yellow tint in the sample
Benefits:
- Easier to use and more accurate than chemical test kits
- Small palm-sized design
- Accurate from ±1.0 ppm; ±5% of reading
- Dedicated to single parameter
- Uses a single AAA battery
- Auto Power-Off after 10 minutes of inactivity
- Built-in timer for timed reaction readings
- Six-month warranty
Primary Applications:
- Water Quality
- Education
- Wastewater
- Environmental
- Aquaculture
- Industrial
Included:
- HI733 Ammonia Checker® HC high range colorimeter
- Sample cuvette and cap (2 pcs.)
- Ammonia HR Range reagent starter kit (reagents for 10 tests)
- 1 mL syringe with tip (1 pc.)
- Plastic pipette (1 pc.)
- 1.5V AAA Alkaline battery (1 pc.)
- Instruction manual
Specifications:
| Range | 0.0 to 99.9 ppm as NH4+ |
| Resolution | 0.1 ppm |
| Accuracy @ 25° C/77 °F | ±1.0 ppm ±5% of reading |
| Light Source | LED @ 470 nm |
| Light Detector | silicon photocell |
| Method | adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample |
| Battery Type | (1) 1.5 V AAA |
| Auto-off | after ten minutes of non-use |
Specifications
| Range | 0.0 to 99.9 ppm as NH4+ |
|---|---|
| Accuracy | +/-1.0 ppm or +/-5% of reading |
| Operating Environment | 0 to 50 degrees C (32 to 122 degrees F); Relative maximum 95% non-condensing |
| D.O.T. Number | Reagent A: UN2922, 8 (6.1), PG II; Reagent B: Not regulated |
| Other | Reagents for 10 tests |
| Dimensions | 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5 in.) |
| Weight | 64 g (2.3 oz) |
| Manufacturer | Hanna Instruments |
| Model No | HI733 |
| Warranty | 6 months |
SDS PDFs
It is our policy to provide the latest Safety Data Sheet (SDS) for all chemicals we ship. Each shipment will contain copies for every chemical contained in the shipment, and for any chemical included in an instrument kit or calibration kit.
Contact us for additional copies of an SDS or for a copy of the Certificate of Analysis:
Phone: 1-800-624-8285
Email: INFO_SDS@preiser.com