Description
Cole-Parmer® Oakton® CON 700 Benchtop Conductivity Meter with Probe and Stand, WD-35411-00
Features:
- An affordable way to take consistent, accurate conductivity measurements in your lab
- Compact size frees up bench space — up to 40% less space than comparable meters
- Large brightly lit display allows for easy reading of measured values
- Easily toggle between conductivity and TDS at the touch of a button
- 0 to 200 mS/cm across five ranges
- Autoranging for the best measurement resolutions
- Up to 5-point calibration (one per range) provides improved measurement accuracy
- Adjustable temperature coefficient for additional accuracy
- Selectible Cell Constant for very high or low-range measurements
- Automatic or manual temperature compensation gives greater precision
- Water-resistant membrane keypad
- Convenient pullout reference guide
- Oversized display
- Ready indicator and HOLD function
- Datalogging for up to 100 points
- Built-in electrode stand can be switched to either side
- Selectable °C or °F
What's Included:
- Conductivity/temperature probe, K = 1.0 91-2619-94
- Built-in electrode stand
- 100 to 240 VAC power adapter
Specifications:
| Meter Type | Benchtop |
| Conductivity Range | 0 µS to 200 mS |
| Conductivity Resolution | 0.01, 0.1 µS; 0.001, 0.01, 0.1 mS |
| Conductivity Accuracy | ±1% full-scale |
| Conductivity Cell Constant | 0.1, 1.0, 10.0; Selectable |
| Conductivity Calibration | Automatic (4 points); Maximum 1/rangeManual (5 points); Maximum 1/range |
| TDS Range | 0 to 100.0 ppt @ 0.5 Factor;0 to 200.0 ppt @ 1.0 Factor |
| TDS Resolution | 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt |
| TDS Accuracy | ±1% of full-scale |
| TDS Factor | Adjustable; 0.40 to 1.00 |
| Range | 0.0 to 100 °C (32.0 to 212.0 °F) |
| Resolution | 0.1 °C / °F |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
| Temperature Compensation | Automatic with supplied cell or manual0.0 to 100 °C (32.0 to 212.0 °F);0.0 to 80 °C (32.0 to 176.0 °F) with supplied cell |
| Temperature Calibration | Offset in 0.1 ° increments;Offset range: ± 5.0 °C (9.0 °F) |
| Temperature Coefficient | 0.0 to 10.00 per °C |
| Temperature Normalization | 15.0 to 30.0 °C (Adjustable) |
| Salinity Accuracy | ± 1.0% full-scale |
| Resistivity Accuracy | ± 1% full-scale |
| Display Type | LCD |
| Display Dimensions (W x H) | 8.3 x 6.2 cm (3-1/4 x 2-7/16 in.) |
| Auto-ranging | YES |
| Hold Function | YES |
| Electrode | Ultem/Stainless Steel probe with Nominal Cell Constant K=1.0, with built-in temperature sensor, and 1 meter cable |
| Input | BNC, 8-pin DIN |
| Interface | RS-232 |
| Power | 100 to 240 VAC, 50/60 Hz;AC/DC 9 V, 6W Adapter |
| Datalogging | 100 data sets |
| CE Compliance | Yes |
| Meter Dimensions (W x H x L) | 6-7/8 x 2-3/4 x 6-1/8 in. (17.5 x 6.9 x 15.5 cm) |
| Model | CON 700 |
| Product Type | Conductivity Meter |
Specifications
| Manufacturer | Cole-Parmer |
|---|