Description
Cole-Parmer® Oakton® PC700 Benchtop pH/Conductivity Meter with pH Electrode, Conductivity/Temperature Probe and Stand, WD-35413-00Features:
- An affordable way to take consistent, accurate conductivity measurements in your lab
- Compact size frees up bench space — up to 40% less space than comparable meters
- Large brightly lit display allows for easy reading of measured values
- Dual display allows reading of the measured parameter plus temperature at the same time
- Easily toggle between pH, mV, conductivity, TDS, and temperature measurements at the touch of a button
- Auto pH buffer recognition for both USA and NIST buffer sets
- 0 to 200 mS/cm across five ranges
- Autoranging for conductivity and TDS provides the best measurement resolutions
- Up to 5-point calibration (one per range) provides improved measurement accuracy
- Adjustable temperature coefficient for additional accuracy
- Selectible Cell Constant for very high or low-range measurements
- Automatic or manual temperature compensation gives greater precision
- Water-resistant membrane keypad
- Convenient pullout reference guide
- Oversized display
- Ready indicator and HOLD function
- Previous calibration points, electrode slope and offset, and conductivity/TDS cell constants are stored in memory for quick and easy retrieval
- Datalogging for up to 100 points
- Built-in electrode stand can be switched to either side
- Selectable °C or °F
What's Included:
- Combination pH electrode, Oakton® 91-2619-90 (WD-59001-65)
- Conductivity/temperature probe, K = 1.0 91-2619-94 (WD-35608-74)
- Built-in electrode stand
- 100 to 240 VAC power adapter
Specifications:
| Meter Style | Benchtop | |
| pH | Range | - 2.00 to 16.00 pH |
| Resolution | 0.01 pH | |
| Accuracy | ± 0.01 pH |
|
| Calibration | Up to 5 points with Auto-buffer recognition | |
| Buffer Options | USA: pH 1.68, 4.01, 7.00, 10.01, 12.45 NIST: pH 1.68, 4.01, 6.86, 9.18, 12.45 |
|
| Slope Display | Yes (with offset) | |
| mV | Range | ± 2000 mV |
| Resolution | 0.1 mV (± 199.9 mV); 1 mV beyond ± 200 mV | |
| Accuracy | ± 0.2 mV (± 199.9 mV); ± 2 mV beyond ± 200 mV or 0.05% whichever is greater |
|
| Offset Adjustment | Up to ± 150 mV | |
| Conductivity | Range | 0 µS to 200.0 mS |
| Resolution | 0.01, 0.1 µS; 0.001, 0.01, 0.1 mS | |
| Accuracy | ±1% full-scale | |
| Cell Constant | 0.1, 1.0, 10.0; Selectable | |
| Calibration | Automatic (4 points); Maximum 1/range Manual (5 points); Maximum 1/range |
|
| TDS |
Range |
0 to 100.0 ppt @ 0.5 Factor; 0 to 200.0 ppt @ 1.0 Factor |
| Resolution | 0.01, 0.1 ppm, 0.001, 0.01, 0.1 ppt | |
| Accuracy | ±1% of full-scale | |
| TDS Factor | Adjustable; 0.40 to 1.00 | |
| Temperature | Range | 0.0 to 100 °C (32.0 to 212.0 °F) |
| Resolution | 0.1 °C / °F | |
| Accuracy | ± 0.5 °C / ± 0.9 °F |
|
| Compensation | Automatic with supplied cell or manual 0.0 to 100 °C (32.0 to 212.0 °F); 0.0 to 80 °C (32.0 to 176.0 °F) with supplied cell |
|
| Calibration | Offset in 0.1 ° increments; Offset range: ± 5.0 °C (9.0 °F) |
|
| Coefficient | 0.0 to 10.00 per °C | |
| Normalization | 15.0 to 30.0 °C (Adjustable) | |
| Display | Type | LCD |
| Dimensions (W x H) | 8.3 x 6.2 cm (3-1/4 x 2-7/16 in.) | |
| Auto-ranging | YES | |
| Hold Function | YES | |
| Electrodes | pH epoxy combination electrode with single-junction, gel, BNC connector, 1 meter cable Ultem/Stainless Steel probe with Nominal Cell Constant K=1.0, with built-in temperature sensor, and 1 meter cable |
|
| Input | BNC, 8-pin DIN | |
| Interface | RS-232 | |
| Power | 100 to 240 VAC, 50/60 Hz; AC/DC 9 V, 6W Adapter |
|
| Datalogging | 100 data sets |
|
| CE Compliance | Yes | |
| Meter Dimensions (W x H x L) | 6-7/8 x 2-3/4 x 6-1/8 in. (17.5 x 6.9 x 15.5 cm) |
|
| Model | PC700 | |
| Product Type | pH, mV,Conductivity,Temperature Meter | |
Specifications
| Manufacturer | Cole-Parmer |
|---|