Description
Thermo Scientific™ Orion™ Star™ A329 pH/ISE/Conductivity/RDO/DO Portable Meter Kit with ROSS Ultra Triode™ Low Maintenance Gel pH/ATC Electrode, DuraProbe™ 4-cell Conductivity Sensor, RDO Optical DO Sensor, Solutions, Meter Armor and Field Case, STARA3295
Features:
- Combined convenience with benefits of pH/ISE meter, conductivity meter and dissolved oxygen meter in one easy-to-use system
- Measure pH, ion concentration, mV, relative mV or ORP with temperature on channel one; measure conductivity, TDS, salinity or resistivity with temperature on channel two; and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel three
- Easily view individual measurements on full screen display and quickly toggle to split screen display to view multiple measurements simultaneously
- Perform up to five point pH and ISE calibrations with calibration editing option that allows individual points to be fixed without a full recalibration
- Perform up to five point conductivity calibration
- Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate
- Use linear, non-linear, EP (USP) or off conductivity temperature compensation with 5 °C, 10 °C, 15 °C, 20 °C or 25 °C reference temperatures
- Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options
- Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Capture your critical readings with measurement stability indicator and selectable read modes — Auto-Read holds stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 5000 measurement sets with optional sample ID and user ID
- Calibration log stores 10 most recent calibrations
- Non-volatile meter memory ensures your data and settings are protected, even with loss of power
- Orion™ Star™ Com software facilitates data transfer to computer via USB or RS232 connections
- Flexible power options with AA batteries or optional universal power adapter
- IP67-rated housing is waterproof for rugged field operation
Included:
- Star™ A329 pH/ISE/Conductivity/RDO/DO Meter with Batteries
- 91-2661-53 (8107UWMMD) ROSS™ Gel-filled Epoxy pH/ATC Triode with 3 Meter Cable
- 91-2661-49 (013010MD) DuraProbe™ Epoxy 4-Probe (K=0.475) Conductivity Probe with 3 Meter Cable
- 91-2661-52 (087010MD) RDO Optical DO Probe with 3 Meter Cable
- 21-2112-04 (910410) Orion™ pH 4.01 Buffer, 10 pouches
- 21-2112-07 (910710) Orion™ pH 7.00 Buffer, 10 pouches
- 21-2112-10 (911010) Orion™ pH 10.01 Buffer, 10 pouches
- 91-2668-06 (810001) Orion™ ROSS™ electrode storage solution, 475 mL
- 17-7109-06 (01100710) Orion™ 1413 µS conductivity standard, 10 pouches
- 21-2112-21 (911110) rinse solution, 10 pouches
- 91-2639-63 (STARA-AR) protective armor with probe holders
- 91-2639-60 (STARA-CS) hard carrying case
- Four AA batteries (installed)
- Printed quick start guide
- Literature CD
- USB computer cable
Specifications:
| Accuracy (Barometer) | ±6 mm Hg |
| Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
| Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
| Accuracy (pH) | ±0.002 |
| Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
| Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
| Accuracy (Resistivity) | 0.5% of reading ±1 digit |
| Accuracy (Salinity) | 0.5% of reading ±1 digit |
| Accuracy (TDS) | 0.5% of reading ±1 digit |
| Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
| Alarm Output | High/low limit alarm, calibration due alarm |
| Backlight Option | Yes, selectable |
| Barometric Pressure Correction | 400 to 850 mm Hg, automatic using built-in barometer or manual entry |
| Battery Life | 800 hr. |
| Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
| Calibration Points (Conductivity) | Up to 5 |
| Calibration Points (ISE) | 1 to 5 |
| Calibration Points (pH) | 1 to 5 |
| Cell Constant | 0.001 to 199.9 cm-1 |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Data Points | 5000 with date and time stamp |
| Channels | 3 |
| Display Type | LCD Graphic, Backlit |
| IP Rating | IP 67 |
| Measurement Modes | pH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature |
| Outputs | USB, RS232 |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
| Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
| Range (TDS) | 0.001 to 200.0 ppm |
| Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
| Resolution (pH) | 0.1/0.01/0.001 |
| Inputs | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature) |
| Isopotential Point | 7.000 pH |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Methods | 10 per channel with password protection |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Pressure Range | 400 to 850 mm Hg |
| Pressure Resolution | 1 mm Hg |
| Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
| Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
| Resolution (mV) | 0.1mV |
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
| Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
| Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
| Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| TDS Factor Range | Linear (0.02 to 9.99) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
| Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Temperature Resolution | 0.1°C, 0.1°F |
| Temperature Selection | Manual or automatic with ATC temperature probe |
Specifications
| Range | pH: -2.000 to 20.000, mV, Relative mV and ORP: +/- 2000.0 mV |
|---|---|
| Range | Conductivity: 0.001 microS/cm to 3000 mS/cm, Resistivity: 2 ohm to 100.0 meg-ohm |
| Range | RDO: 0.00 to 50.00 mg/L, Polarographic DO: 0.00 to 90.00 mg/L |
| Range | Temperature: - 5 to 105 degrees C (22.0 to 221.0 degrees F) |
| Power | 4 AA (included) / Universal 50-60 Hz, 100-240 VAC power adapter (optional) |
| Compliant/Standard | CE, TUV 3-in-1 and FCC Class A |
| Operating Environment | Ambient Temperature: 5 degrees C to 45 degrees C (41 degrees F to 113 degrees F), RH: 5 to 85 %, non-condensing |
| Connectivity | Input: pH: BNC/reference pin, Conductivity: 8 pin Mini-DIN, DO: 9-pin Mini-DIN |
| Connectivity | Output: RS232, USB |
| Dimensions | L x W x H: 24 cm x 10 cm x 6.5 cm (9.5 in. x 3.9 in. x 2.6 in.) |
| Weight | 0.5 kg (1.2 lb.) |
| Manufacturer | Thermo Scientific Orion |
| Model No | STARA3295 |
| Warranty | 3 year |
SDS PDFs
It is our policy to provide the latest Safety Data Sheet (SDS) for all chemicals we ship. Each shipment will contain copies for every chemical contained in the shipment, and for any chemical included in an instrument kit or calibration kit.
Contact us for additional copies of an SDS or for a copy of the Certificate of Analysis:
Phone: 1-800-624-8285
Email: INFO_SDS@preiser.com