Description
Thermo Scientific (Trademark) Orion (Trademark) Dual Channel pH/Ion Bench Meter Only with Stand, PSTAR2170
Features:
- Parameters: pH, mV, ORP, temperature
- Large 7-inch, high-resolution color display
- Responsive capacitive touchscreen operable with gloves
- Angled display to help ensure ergonomic viewing
- Streamlined, easy to operate user interface
- Vertical meter orientation helps optimize bench space
- Supports GLP compliance
- Select 1 to 5 point calibrations
- Stores 20 calibration logs per parameter with date and time
- Stores 10,000 data log sets with date and time
- Outputs to printer, computer, or USB flash drive for long-term data retention
- Inputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse
- Optional meter-controlled and meter-powered stirrer probe
- Stand has stable, weighted base and side channel to keep cables neatly organized - offers smooth, secured movement of variety of electrodes
Specifications:
pH
| Range | –2.000 to 20.000 pH |
| Resolution | 0.1, 0.01 or 0.001 pH |
| Relative Accuracy | +/- 0.002 pH |
| Calibration Points | 1 to 5 |
| Calibration Method | Automatic buffer recognition, manual entry option |
| Calibration Buffer Sets | USA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); up to 5 custom buffers |
| Slope Type | Linear or segmented |
| Calibration Summary | Slope and EO offset, option to view as point-to-point graph |
| Isopotential Point | 7.000, user adjustable |
| Input Impedance | >1012 Ohm |
mV
| Range | –2000.0 to 2000.0 mV |
| Resolution | 0.1 mV |
| Relative Accuracy | +/-0.2 mV or ±0.05% of the reading, whichever is greater |
Relative mV/ORP
| Range | –2000.0 to 2000.0 mV |
| Resolution | 0.1 mV |
| Relative Accuracy | +/-0.2 mV or ±0.05% of the reading, whichever is greater |
| Calibration Points | 1 point |
| Calibration Method | ORP or EH |
| Calibration Offset | +/-250 mV |
Ion
| Range | 0.0001 to 19999 |
| Resolution | 0.0001 minimum, 1 to 5 digits |
| Relative Accuracy | +/-0.2 mV or +/-0.05% of the reading, whichever is greater |
| Units | ppt, ppm, ppb, mg/L, M, mM, %, none or user-defined |
| Calibration Points | 1 to 5 points |
| Calibration Method | Automatic standard recognition, manual entry option |
| Calibration Standards | 1.000, 10.00, 100.0, 1000, 10000 or up to 5 custom standards |
| Slope Type | Linear or segmented |
| Calibration Summary | Slope and EO offset, option to view as point-to-point graph |
| Isopotential Point | 1.000, user adjustable |
| Blank Correction | Yes |
| Low Level Stability | Yes |
| Incremental Techniques | Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction |
Temperature
| Range | –30.0 to 130.0 degrees C / –22.0 to 266.0 degrees F |
| Resolution | 0.1 degrees C / 0.1 degrees F |
| Relative Accuracy | +/- 0.3 degrees C / +/-0.5 degrees F |
| Calibration Points | 1 to 2 |
| Offset Adjustment | Up to 5.0 degrees C |
| Temperature Source | Automatic with ATC sensor, ambient with built-in meter temperature sensor or manual entry |
Measurement Functions
| Measurement Channels | 2 |
| Measurement Parameters | Channel 1: pH, mV, ORP or ion concentration with temperature; Channel 2: pH, mV, ORP or ion concentration with temperature |
| Read types | Continuous, Auto-Read or Timed |
| Timed Reading Intervals | 3 seconds to 2 hours |
| Measurement Layout | Customizable options for basic, advanced or user-defined |
| Measurement Stability | Automatic, fast, medium or slow |
| Sample ID | Auto-incremental or manual, up to 25 alphanumeric characters |
| Electrode ID | Up to 20 alphanumric characters |
| Graph/Chart View | Single parameter with temperature |
| Set Value Alarm | 1 high and 1 low value per parameter |
| Last Calibration Details | Calibration summary with date and time |
Meter Features
| Display | 7-inch, high-resolution color graphic LCD |
| Touchscreen Type | Capacitive with lab glove compatibility |
| Onscreen Prompts | On-demand information screens; onscreen user guide and step-by-step calibration guidance |
| Time and Date | Yes |
| Time Format | 12 or 24 hrs |
| Date Format | Selectable as MM-DD-YYYY, DD-MM-YYYY or DD-MMM-YYYY |
| Instrument Name | Up to 20 alphanumeric characters |
| Secure Mode | 3 administrator and 30 user accounts with individual password protection, custom user access permissions and audit trail |
| Username | Up to 20 alphanumeric characters |
| Methods | 10 (20 total) |
| Data Outputs | USB flash drive, computer or compact ink printer |
| Data Output Format | CSV or print |
| Data Log | 10,000 data sets with time and date |
| Data Log Export | Customizable options for basic (short), intermediate, advanced or all data |
| Calibration Log | 20 per parameter with time and date |
| Calibration Log Export | Customizable options for basic (short), intermediate, advanced or all data |
| Calibration Reminder | 1 alarm per parameter |
| Calibration Alarm Interval | 1 hour to 30 days or off |
| Audible Signal | User set for notifications and alarms, stable reading |
| Maintenance Reminder | Up to 5 electrode maintenance reminders and up to 5 solution maintenance reminders |
| Sleep Mode | Selectable time interval of 5, 10, 20, 30, 60 minutes or off |
| Meter tests | Self-test, stability test and pH electrode check |
| Meter Tour and Guides | Calibration modes, measurement mode, meter connections, electrode stand assembly and pH electrode maintenance |
| Stirrer Probe Inputs | 2 |
| Stirrer Probe Speeds | 5 selectable speeds from 250 RPM to 3600 RPM |
| Electrode Inputs | Channel 1: BNC, 8-pin MiniDIN (ATC), reference pin-tip; Channel 2: BNC, 8-pin MiniDIN (ATC), reference pin-tip |
| Data Outputs | 1 USB-A port for USB flash drive; 1 export port for computer or compact ink printer |
| Accessory Input | 1 USB-A port for USB mouse, USB keyboard or USB barcode scanner |
| Memory | Non-volatile, to preserve data and settings in case of power loss |
| Display Languages | Chinese, English, French, German, Italian, Japanese, Korean, Portuguese or Sp |
Included:
- Pro Star PD217 Dual Channel pH/Ion and DO Bench Meter
- Stand with weighted base
- USB flash drive
- Computer cable, 100-240V 50/60Hz
- Universal power adapter (purchase electrodes separately)
Specifications
| Range | pH: 2.000 to 20.000 pH |
|---|---|
| Range | mV/Relative mV/ORP: 2000.0 to 2000.0 mV |
| Range | Ion: 0.0001 to 19999 |
| Range | Temperature: 30.0 to 130.0 degrees C / 22.0 to 266.0 degrees F |
| Power | 100-240 VAC, 50-60Hz, 9 DC adapter, 2.0A |
| Compliant/Standard | CE, TUV 3-1, FCC Class A, IP-54 |
| Dimensions | L x W x H: 218.9 x 153.2 x 91.62 mm / 8.62 x 6.03 x 3.61 in. |
| Weight | 1.00 kg / 2.20 lbs. |
| Manufacturer | Themo Scientific Orion |
| Model No | PSTAR2179 |
| Warranty | 2 Years |