Description
Cole-Parmer® Oakton® PD 650 Waterproof Handheld Meter Kit, WD-35432-70
Features:
- Top-of-the-line dual parameter meter measures choice of pH, mV, or ISE and Dissolved Oxygen simultaneously as well as temperature
- Logs up to 500 data point sets with date/time stamp for GLP compliance
- Wireless IrDA communication for waterproof interfacing capabilities
- "Calibration Due" alarms user selectable
- Single or multiple calibration points with automatic or manual standards recognition
- Large, backlit LCD shows measured values, units, temperature, time, battery life and menu options
Included:
- PD 650 Meter
- Double Junction pH Electrode, 25 ft. cable
- Galvanic DO Probe, 25 ft. cable
- Probe Holder
- Data management software
- Electrolyte solution
- Protective rubber boot
- Hard carrying case
Specifications:
|
pH |
Range | - 2.000 to 20.000 pH units |
| Resolution | 0.1 / 0.01 / 0.001 pH units | |
| Relative Accuracy | ± 0.002 pH + 1 LSD | |
| Calibration Points | 1 (offset) to 6 points | |
| Buffer Options | 15 | |
| Calibration Due Alarm | User configurable (up to 30 days) |
|
| Set Point Alarm | User configurable | |
| Automatic Buffer Recognition |
Yes | |
| pH Buffer Groups & Calibration Points |
USA: 1.68, 4.01, 7.00, 10.01, 12.45 NIST: 1.68, 4.01, 6.86, 9.18, 12.45 DIN: 1.09, 3.06, 4.65, 6.79, 9.23, 12.74 PWB: 4.10, 6.97 |
|
| Calibration Window |
USA: ± 1.5 pH (for 7.00 pH), ± 1 pH (all other buffers) NIST: ± 1.35 pH (for 6.86 pH), ± 1 pH (all other buffers) DIN: ± 0.8 pH (for 1.09, 3.06, 4.65 pH), ± 1 pH (for 9.23, 12.74 pH), ± 1.34 pH (for 6.79 pH) PWB: ± 0.8 pH |
|
| Custom Buffer Calibration | Yes (2 to 5 points) | |
| Slope/Offset Display | Yes (Display + Icon) | |
|
mV |
Range | ± 2000.0 mV |
| Resolution | 0.1 mV | |
| Relative Accuracy | ± 0.2 mV + 1 LSD | |
| Ion | Range | 0.001 to 19900 |
| Units | ppm, molar, mg/L | |
| Resolution | 2 or 3 digits | |
| Relative Accuracy | 0.5% full scale (monovalent), 1% full scale (divalent) |
|
| DO | Range | 0 to 600% / 90 mg/L |
| Resolution | 0.1 %, 0.01 mg/L | |
| Accuracy | ± 2%, ± 0.2 mg/L | |
| Dissolved Oxygen Probe | Galvanic | |
| Mode | % Saturation, mg/L, ppm | |
| Temperature Compensation | Linear | |
| Barometric Pressure Compensation |
Automatic | |
| Barometric Pressure Range | 450 to 825 mm Hg | |
| Barometric Pressure Resolution |
1 mm Hg | |
| Barometric Pressure Accuracy | ± 1% | |
| Salinity Correction | 0 to 50 ppt | |
| Calibration Due Alarm | User configurable (up to 30 days) | |
| Set Point Alarm | Yes | |
| Input DO | 6 pin round | |
| Display | Type | Dot Matrix LCD with backlighting |
| Screen Resolution | 110 x 128 | |
| Viewing Area | 68 x 74 mm | |
| Backlit | Yes | |
| Other | Data logging | 500 data sets |
| Data Communication | IrDA / RS-232C Infrared | |
| Automatic Data Logging | Yes | |
| GLP (Good Lab Practice) | Yes | |
| Ingress Protection | IP 67 | |
| Dimensions, W x L x H |
Without Boot: 95 x 185 x 58.5 mm With Boot: 101 x 191 x 61 mm |
|
| Weight | 380 g (without boot) | |
| Power Input | Battery | 4 x alkaline AA size, 1.5 V |
| Battery Life | 200 hrs (without backlight & serial data transfer) | |
| Power Adapter (optional) |
Input: 100 to 240 VAC Output: DC 9 to 12 V, 6 W Maximum |