TL2350 Tungsten Lamp Turbidimeter, EPA Approved, 0 to 10000 NTU, HACH, LPV444.99.00310

Item: 92-2456-03-EA

Description

HACH® TL2350 Tungsten Lamp Turbidimeter, EPA Approved, 0 to 10000 NTU, LPV444.99.00310

Features:

  • Large full color touch screen display and intuitive user interface accelerate setup, calibration and measurement
  • Easy interface and guided procedures give reliable results
  • USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance —  Hach® makes it easy to Be Right
  • Ensures stable readings and accurate analysis by capturing turbidity readings once device detects sample stability — quality step removes subjectivity and  need for repeated measurements

Included:

  • TL2350 Turbidimeter
  • Silicone oil
  • Oiling cloth
  • USEPA filter assembly
  • 1-inch sample cells (30 mL) with caps (6x)
  • Gelex secondary turbidity standardization kit
  • Stablcal calibration kit
  • Power supply
  • Power cord
  • Dust cover

Specifications:

Accuracy

Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of reading from 1000 - 4000 NTU ±10 % of reading from 4000 - 10000 NTU

Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU

Accuracy 3

Absorbance: ±0.01 Abs from 0 - 0.5 Abs at 455 nm, ±2% Abs from 0.5 - 1 Abs at 455 nm

Transmittance: 2% T from 10 - 100% T at 455 nm

Air Purge

Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)

0.1 scfm at 69 kPa (10 psig); 138 kPa (20 psig) max

Hose barb connection for 1/8-inch tubing

Communication USB
Data Logging 2000 total logs, includes reading log, verification log and calibration log
Display 17.8 mm (7 in.) color touch screen
Light Source Tungsten filament lamp
Measurement Method Nephelometric
Model TL2350 EPA
Reading Modes Single, continuous, Rapidly Settling Turbidity™, signal averaging on or off, ratio on or off
Regulatory Meets EPA Method 180.1
Repeatability ±1% of reading or 0.01 NTU, whichever is greater (under reference conditions)
Response Time Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average)
Sample Cell Compatibility

Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps

Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used.

Sample Requirements 25 mm sample cell: 20 mL minimum
0 to 70 °C (32 to 158 °F)
Source Lamp Tungsten Lamp
Stabilization Time

Ratio on: 30 minutes after start-up

Ratio off: 60 minutes after start-up

Storage Conditions -20 to 60 °C
Units NTU, EBC, Abs (absorbance), %T (% transmittance) and mg/L

Specifications

Specifications
Range Turbidity: Ratio on: 0 - 10000 NTU Ratio off: NTU (Ratio off): 0 - 40
Range Turbidity: Ratio on: 0 - 2450 auto decimal, Ratio off: 0 - 9.8
Range Absorbance (auto range): 0 - 1.0, Transmittance: 1.0 - 100%
Range Degree (mg /L): 1 - 100
Power 100 - 240 VAC, 50 -60 Hz, 3.4 A
Compliant/Standard EPA Method 180.1, CE, KC, RCM
Operating Environment 0 - 40 degrees C
Connectivity Output: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner
Dimensions H x W x D: 153 mm x 395 mm x 305 mm
Weight 3.0 kg
Manufacturer HACH
Model No LPV444.99.00310
Warranty 12 months