Versa Star Dissolved Oxygen/RDO/Temperature Measurement Module, Orion, VSTAR-RD

Item: 91-2639-114-EA

UOM: EA (1)
Price:
Sale price$1,370.00

Description

Thermo Scientific™ Orion™ Versa Star™ Dissolved Oxygen/RDO/Temperature Measurement Module, VSTAR-RD

Features:

  • Add dissolved oxygen and temperature measurement capabilities to Thermo Scientific™ Orion™ Versa Star™ meter with this module
  • Each Orion™ Versa Star™ meter has four channels that can be customized with interchangeable measurement modules
  • Orion™ Versa Star™ RDO/DO module offers the flexibility to use Orion™ RDO optical or polarographic probes with automatic sensor recognition and calibration using water-saturated air, air-saturated water, custom value using Winkler titration and zero point options

Specifications:

Accuracy (Polarographic DO) ±0.2 mg/L or ±2% of reading, whichever is greater
Accuracy (RDO) ±0.1 mg/L up to 8 mg/L, ±0.2mg/L from 8 to 20 mg/L, ±10% of reading up to 50mg/L
Accuracy (Barometer) ±6 mm Hg
Accuracy (Temperature) ±0.1 °C
Alarm Output Set point alarm, high/low limit alarm, calibration due alarm
Barometric Pressure Correction 400 to 850 mm Hg, automatic using built-in barometer or manual entry
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Includes Versa Star RDO/DO module and printed quick start guide
IP Rating IP-54
Measurement Modes Dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Methods 10 per channel with password protection
Percent Saturation Range (RDO) 0.0 to 500.0 % saturation
Percent Saturation Resolution (RDO) 0.1, 1% Saturation
Pressure Range 400 to 850 mm Hg
Pressure Resolution 0.1 mm Hg
Probe Type RDO optical dissolved oxygen probe, polarographic dissolved oxygen probe (purchase separately)
Percent Saturation Relative Accuracy (Polarographic DO) ±2% Saturation
Resolution (Polarographic DO) 0.01, 0.1 mg/L; 0.1, 1 % saturation
Resolution (RDO) 0.01, 0.1 mg/L; 0.1, 1 % saturation
Resolution (Temperature) 0.1 °C
Salinity Factor 0 to 45 ppt
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Temperature Probe Calibration 1 point temperature offset calibration
Temperature Selection Automatic with ATC temperature probe
Percent Saturation Resolution (Polarographic DO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (RDO) ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Percent Saturation Range (Polarographic DO) 0 to 600% Saturation

Specifications

Specifications
Range Polarographic DO: 0.00 to 90.00 mg/L
Range RDO: 0.00 to 50.00 mg/L
Range Temperature: -5 to 105 °C, 22 to 221 °F
Accuracy Polarographic: +/-0.2 mg/L or +/-2% of reading, whichever is greater, RDO: +/-0.1mg/L up to 8mg/L, +/-0.2mg/L from 8 up
Operating Environment 5 degrees C to 45 degrees C (41 degrees F to 113 degrees F), Relative Humidity: 5 to 85 %, non-condensing
Connectivity 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)
Dimensions 12 x 3 x 9.5 cm (4.7 x 1.2 x 3.8 in.)
Weight 0.2 kg (0.5 lb)
Manufacturer Thermo Scientific Orion
Model No VSTAR-RD
Warranty 3 year meter replacement

You may also like