Description
In-Situ™ Aqua TROLL® Rhodamine WT Sensor for Use with Aqua TROLL® 500/600, 0038890
Features:
- Improves accuracy of tracer studies with patented Integrated Optical Compensation — a second detector to compensate for LED drift over temperature and time for increased accuracy and stability
- Provides stability at lower detection limits for more detailed river, coastal and groundwater studies
- Blocks external light to reduce bias
- Each In-Situ™ fluorometer sensor uses a separate frequency providing a unique digital signature for each light source to minimize interference between sensors when used in combination
- Internal diagnostics, lower calibration solution volume, and one- or two-point calibration means less maintenance is required
- Reduces monitoring costs because only necessary sensors to monitor the parameters of interest need to be purchased
- Sensors retain their calibration data so they can easily be transferred to different sondes
- Fluorometer sensors can be used to monitor rivers, lakes or coastal waters — Rhodamine WT sensor is particularly ideal for tracer studies, contaminant fate and transport studies, and groundwater applications
Specifications:
| Linearity | R²>0.999 for serial dilutions of Rhodamine WT across full range |
| Range | 0-100 RFU;0-1000 µg/L |
| Resolution | 0.001 RFU0.01 µg/L |
| Response Time* | T63<1 s, T90<1 s, T95 <1 s |
| Units of Measure | RFU, µg/L |
| Operating Temperature | - 5 to 50 °C (23 to 122 °F) |
| Storage Temperature | - 40 to 65 °C (-40 to 149 °F) |
| Wetted Materials | Titanium, Sapphire, Polycarbonate, Nylon, Viton® |
| Environmental Rating | System: IP68 when installed in SondeSensor: IP67 when not installed |
| Maximum Pressure Rating | Equivalent to maximum pressure of sonde |
| Product Compatibility | Aqua TROLL® 500 and Aqua TROLL® 600 |
| Warranty | 2 years on sensor |
* Response time is typical when moving from air to ambient water temperature
Aqua TROLL® Sensors:
| Cat. No. | Mfg P/N | Description |
| 92-1629-09 | 0063490 | AT Temperature Sensor |
| 92-1629-10 | 0063470 | AT pH/ORP Sensor |
| 92-1629-16 | 0063460 | AT Temperature/Conductivity Sensor |
| 92-1629-17 | 0063450 | AT RDO Sensor w/RDO-X cap |
| 92-1629-21 | 0033700 | AT Ammonium ISE Sensor |
| 92-1629-22 | 0033710 | AT Nitrate ISE Sensor |
| 92-1629-23 | 0033720 | AT Chloride ISE Sensor |
| 92-1629-24 | 0038900 | AT Chlorophyll a Sensor |
| 92-1629-25 | 0038920 | AT Phycocyanin (BGA-PC) Fluorometer Sensor |
| 92-1629-26 | 0038930 | AT Phycoerythrin (BGA-PE) Fluorometer Sensor |
| 92-1629-27 | 0038890 | AT Rhodamine WT Fluorometer Sensor |
| 92-1629-37 | 0063480 | AT Turbidity Sensor |
Other Aqua TROLL® Accessories:
| Cat. No. | Mfg P/N | Description |
| 92-1629-12 | 0063510 | AT Sensor Port Plug |
| 92-1629-13 | 0063500 | AT Wiper |
| 92-1629-14 | 0064630 | AT Wiper Port Plug |
| 92-1629-15 | 0076100 | AT Copper Antifouling Restrictor Guard |
| 92-1629-31 | 0053310 | RuggedCable® Connector W/Male Connector End to Stripped & Tinned End |
| 92-1629-32 | 0052500 | TROLL Com® Bundle w/USB Connector & Software CD |
| 92-1629-35 | 0020680 | Conductivity Calibration Sol'n 1413 µS, 1 L |
| 92-1629-42 | 0051810 | Lg Desiccant w/Titanium Connector f/Vented RuggedCable Systems |
| 92-1629-43 | 0031240 | Wireless TROLL Com® for Aqua TROLL® & Level TROLL® |
| 92-1629-51 | 0061150 | Rugged Android™ 7" Tablet |
| 92-1629-53 | 0029140 | Desiccant Refill Kit |
| 92-1629-71 | 0052000 | RuggedCable® Systems for Aqua TROLL® & Other In-Situ™ Instruments |
Specifications
| Application | Environmnetal monitoring |
|---|---|
| Manufacturer | In-Situ Inc |
| Model No | 0038890 |

