Description
All GenPure™ systems exceed international standards ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW Features: xCAD (Extended Control and Dispenser):
- System proves more flexibility for ultrapure water dispensing with an action radius of 32" (80 cm)
- Ergonomic dispensing arm provides precise volume dosing at the press of a button
- Flexible dispenser offers positions including turned, height adjusted or extended toward you vessel
- One-of-a-kind design provides access to all system controls at your fingertips.
- Each system ships with a single xCAD Plus remote dispenser
- For increased flexibility, add one or two more xCAD Plus dispensers
- Additional measuring cell monitors feed water conductivity
- If the quality of the feed water drops below the set value, a fault message will immediately be displayed
- Real-time TOC monitoring offers continual measurement of organic substances present in the water
- Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity
- Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements
- High performance UV assembly reliably reduces the content of microorganisms and their metabolites
- UV oxidation also reduces organic compounds in the water to ultra-low levels
- An error message is displayed when internal leaks are detected
- Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge sterile filter, all are included in one part number
- Conductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01 cm¯¹
- Temperature measurements are made by a platinum chip sensor with ±0.1ºC accuracy
- Aquastop quick-connect capability enables cartridge replacement within seconds even mid-operation
- Electronic dosing yields fully automatic volume control of 0.01-65 L with <2% accuracy.
GLP-compliant documentation:
Specifications: - Real-time clock and code-protected operating system prevents unauthorized changes to system settings
- RS-232 interface with adjustable send-interval for safe data transfer of all measured data, faults, date and time to a PC computer or log printer
- Digital microprocessor control automatically monitors and stores faults from the last four weeks
- USP-compliant conductivity measurement with temperature compensation can be switched on or off
| Flow Rate, min. | Up to 2 L/min. |
| Operating Pressure min. and max | 0.1 to 6 bars |
| Total Organic Carbon | 1 to 5 ppb |
| Bacterial content | <0.01 CFU/mL |
| Particles > 0.2µm/mL | < 1 |
| Feed Water Monitoring | Integrated |
| Feed Water Connector | 3/4 in. NPT |
| Dimensions (D x W x H) | 13 x 14.6 x 24 in. (330 x 372 x 615 mm) |
| Conductivity | 0.055µS/cm |
| Resistance @ 25°C | 18.2MΩ-cm |