Description
HACH® HQ2200 2-Channel Portable Multi-Meter pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP, without Electrodes, LEV015.53.2200A
Features:
- Illustrated, step-by-step, on-screen calibration procedures to make calibration a breeze
- IntelliCAL? smart sensors available separately with HQ Series to measure wide variety of parameters including Total Dissolved Solids (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Temperature, Conductivity, and pH — purchase the sensors to customize instrument for your application
- IntelliCAL? sensors are automatically recognized by meter and retain their calibration history and methods settings and can be switched between multiple meters as needed
- These sensors deliver superior accuracy and response times
- Data from your lab or field work can be safely transferred from meter to computer via USB
- HACH has over 80 years electrochemistry expertise and provide reliable technical support and field service
Included:
- HQ2200 Portable pH/ORP/EC/TDS/DO Multi-Meter, 2 channels
- Manuals
- Li-Ion batteries, rechargeable
- USB charger with cable for USA
Specifications:
| Temperature correction | None; Linear; NaCl Non-Linear Natural Water. |
| Accessories Included | USB charger, power cable, and clips |
| Automatic Buffer Recognition | Yes |
| Backlight | Yes |
| Barometric Pressure Measurement | Automatic compensation of DO when using an LDO or LBOD probe |
| Calibration | Demal (1 D/ 0.1 D/ 0.01 D); Molar (0.1 M/ 0.01 M/0.001 M); NaCl (0.05%; 25 µS/cm; 1000 µS/cm; 18 mS/cm); Standard sea water; User defined |
| Calibration Intervals/Alerts/Reminder | Off, selectable from 2 hours to 7 days |
| Conductivity Measurement Range | Yes |
| Custom Calibration Standards | Yes |
| Data Memory | 10,000 data points |
| Data Storage | Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. |
| Display | Up to 3 parameters at a time, dependent on HQ model |
| Display Type | 536 x 336 Mono-TFT |
| DO Resolution | 0.1 |
| Enclosure Rating | IP67 (with battery compartment installed) |
| GLP Features | Date; Time; Sample ID; Operator ID, Calibration |
| Instrument | Portable |
| ISE Direct Measurement Range | No |
| ISE Electrode Calibration | No |
| Kit? | Meter only |
| Languages | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
| Lock Function | Continuous / Auto-stabilization ("press to read") / At Interval |
| Measurement Method | Probe specific programmed method settings |
| Model | HQ2200 Multi/2 Channels |
| mV Measurement at Stable Reading | Yes |
| mV Measurement Range | Yes |
| mV Resolution | 0.1 mV |
| Operating Error Messages | Clear text error messages displayed |
| Operating Interface | Soft Touch Keypad |
| ORP Electrode Calibration | Predefined ORP standards (including Zobell's solution) |
| Parameter | pH, Conductivity, TDS, Salinity, Dissolved Oxygen (DO), ORP |
| pH Buffer Sets | Colour-coded: 4.01, 7.00, 10.01 pH; IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45; DIN: 1.09, 4.65, 9.23; User-defined custom buffer sets |
| pH Electrode calibration | 1 - 3 Calibration points Calibration summary data logged and displayed |
| pH Resolution | Selectable: 0.001/0.01/0.1 pH |
| Probe Type | Intellical Standard Laboratory or Rugged Field |
| Probes included | None |
| Protection Class | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
| Salinity Resolution | 0.01 (ppt) (‰) |
| Sensor A | None |
| Sensor B | None |
| Sensor C | None |
| Storage Conditions | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
| TDS Resolution | 0.01 mg/L - 0.1 g/L upon measuring range |
| Temperature Compensation | Automatic Temperature compensation for pH |
| Temperature Measurement | °C or °F |
| Temperature Resolution | 0.1 °C |
| Type of measurement | Field Measurements |
Specifications
| Range | pH: 0 to 14 pH units / ORP: -1200 to 1200 mv |
|---|---|
| Range | DO: 0.1 to 20.0 mg/L (ppm), 1 to 200% saturation / TDS: 0.00 mg/L to 50.0 g/L NaCl |
| Range | Salinity: 0 to 42 ppt / Resistivity: 0.5 to 49999900.0 omega·cm |
| Range | Conductivity: 0.01 to 9998.90 microS/cm or 0.0 to 1999.9 mS/cm |
| Power | Rechargeable Li-ion battery 18650 / Class II, USB power adapter: 100 /240 VAC, 50/60 Hz input; 5 VDC at 2A |
| Compliant/Standard | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
| Operating Environment | 0 to 60 degrees C / Relative Humidity Maximum: 90% |
| Connectivity | Input: Dual-channel sensor inputs / USB Power adapter |
| Connectivity | Output: USB connection to PC or USB storage device (limited to storage device capacity) |
| Dimensions | H x W x D: 63 mm x 97 mm x 220 mm |
| Weight | 541 g (meter only) |
| Manufacturer | HACH |
| Model No | LEV015.53.2200A |