Intellical ISENH3181 Ammonia (NH3) Ion Selective Electrode (ISE), 1 m Cable

Item: 91-2599-96-EA

UOM: EA (1)
Price:
Sale price$1,202.00

Description

HACH™ Intellical™ Intellical ISENH3181 Ammonia (NH3) Ion Selective Electrode (ISE), 1 m Cable

Features:

  • A digital, combination gas-sensing, ammonia ion selective electrode (ISE) with a replaceable membrane module
  • Refillable outer body, a non-refillable gel 3M KCl reference with a double junction porous PTFE annular ring and built-in temperature sensor
  • Measures ammonia concentration in water samples
  • 50 mL bottle of 0.1 M NH4Cl Electrode Filling Solution is included with the probe
  • Laboratory version of this ISE is shockproof with its Epoxy plastic body
  • Available with a 1 or 3 meter cable and is intended for laboratory use
  • Ideal for measuring ammonia concentrations in wastewater, drinking water and general water quality applications
  • Provides fast, stable, and accurate results
  • Ultimate traceability in measurement history
  • User alerted when re-calibration is needed
  • Can be moved between meters without the need to re-calibrate or re-enter measurement settings

Specifications:

Accuracy
±0.02 mV or 0.05%, whichever is greater
Cable Length 1.0 m (3.28 ft)
Electrode Type
Non-refillable, gel-filled reference element with replaceable membrane
Filling Solution
0.1 M NH4Cl (#4447226)
ISA Required
Ammonia ISA (#4447169)
Junction Type Double annular junction
Probe Length
175 mm (6.89 in.)
Range 0.01 mg/L (5 x 10-7 M) to 14 g/L (1 M) NH3-N
Resolution Selectable up to 4 significant digits
Reference Type
Ag/AgCl
Sample Depth
25.4 mm (1 in.)
Sample Volume
15 mL
Sensor Material Epoxy
Sensor Type pH Glass with replaceable NH3 sensitive membrane
Special Feature
Easy-to-replace membrane modules
Temperature Accuracy ±0.3 °C (±0.54 °F)
Temperature Range 0 to 50 °C (32 to 122 °F)
Temperature Resolution 0.1 °C (0.18 °F)
Thermistor ATC
Weight 0.1 kg
Included IntelliCal combination Ammonia ISE electrode, 1 m cable, 3-pack of replacement Intellical Ammonia membrane modules (#4 test certificate and basic user manual

 

Specifications

Specifications
Range Ammonia: 0.01 mg/L (5 x 10-7 M) to 14 g/L (1 M) NH3-N
Range Temperature: 0 to 50 °C (32 to 122 °F)
Material Epoxy Body with glass sensor and replaceable NH3 sensitive membrane
Application Wastewater, drinking water and general water quality applications
Accuracy Ammonia: ±0.02 mV or 0.05%, whichever is greater; Temperature: ±0.3 °C (±0.54 °F)
Other Cable Length: 1 m
Weight 0.1 kg
Manufacturer HACH
Model No ISENH3181

You may also like