Description
Myron L® Ultrapen™ PT3 ORP/REDOX & Temperature Pen, PT3Features:
Specifications:
* Temperature compensation in calibration mode: Temperature affects the reaction potentials for all chemicals differently. True ORP is the direct measurement of electron activity during an oxidation-reduction reaction, regardless of temperature. However, for maximum accuracy and case of calibration, the Myron L® Company has developed three calibration solutions with known dissolved species. Temperature compensation for those solutions has been derived (from 15 to 30 °C) and embedded in the calibration function of the PT3. Note: to verify calibration while in measurement mode, the temperature variation must be manually corrected. Example: @ 25 °C, ORP2602OZ calibration solution will read 260 mV, and @ 20 °C it will read 265 mV.
- Fast, accurate (± 10 mV ORP) and easy-to-use
- 3 calibration options
- Proprietary sensor design
- 99.9% pure platinum electrode
- Automatic temperature compensation in calibration mode *
- Affordable, portable pen provides the accuracy of a benchtop meter
- Rugged, reliable, water-proof, shock-resistant construction of aircraft grade aluminum fully protects inside electronics
- Simple, one-button operation
- Temperature readout
- Includes high-capacity N-type battery
- User replaceable ORP sensor
- 1 year warranty excluding ORP sensor, 6 months on ORP sensor (battery not warranted)
| Agriculture | Hydroponics | Desalination |
| Aquaculture | Pharmaceutical | Boilers/Cooling Towers |
| Wastewater | Horticulture | Pool/Spa |
| Food/Beverage | Irrigation | Reverse Osmosis |
| Fountain Solutions for Printing | ||
| ORP | Range | -1000 mV to +1000 mV |
| Resolution | 1 mV | |
| Accuracy | ± 10 mV | |
| Temperature | Range | 0-71 °C or 32-160 °F |
| Resolution | 0.1 °C or 0.1 °F | |
| Accuracy | ± 0.1 °C or ± 0.1 °F | |
| Compensation | Automatic in calibration modefrom 15 to 30 °C | |
| Operating/Storage | 0-55 °C or 32-131 °F | |
| Time to Reading Stabilization | 10 to 45 seconds | |
| Power Consumption | Active Mode | 37 mA |
| Sleep Mode | 2 µA | |
| Dimensions, Length x Diameter | 17.15 x 1.59 cm or 6.75 x 0.625 inches | |
| Weight | 50.4 g or 1.78 oz (without soaker cap & lanyard) | |
| Case Material | Anodized aluminum with UV protective coating | |
| Battery | Type | N-type, alkaline |
| Voltage | 1.5 V | |
| Calibration Solutions | ORP80, ORP260, ORP470 | |
| Water Resistance | IP67 and NEMA 6 | |
| Certification | CE | |
| EN61236-1: 2006 — Annex A: 2008; 0995/5/EC Annex III:Electrostatic discharge to case of insturment may cause PT3 to spontaneously power ONIn this case, the PT1 will power OFF after several seconds | ||