Description
Thermo Scientific™ Orion™ AQUAfast™ Turbidity Meter Kit, AQ3010
Features:
- Generate an accurate turbidity readings in seconds with simple turbidity meter that offers an impressive array of features
- Results are easy to read and record from the large, bright LCD display in a variety of work environments
- Ergonomic IP67 turbidity meter for lab or field use
- Autoranging from 0 to 1000 NTUs
- Uses Nephelometric principle with 90° detection
- Separate light cap or shield is not needed in many locations
- Meets ISO 7027 and offers consistent light source for greater accuracy
- No mixing or diluting with EPA-approved polymer bead primary standards for faster calibration
Specifications:
| Measurement Method | ISO 7027 compliant nephelometric method (90 °) |
| Light Source | Infrared LED (for ISO 7027 Turbidity measurement) (850 nm wavelength) |
| Light Source Life | > 1,000,000 tests |
| Detector | Silicon photovoltaic |
| Display Type |
4 digit 14 segments customized liquid crystal display with annunciators (LCD) |
| Stray Light | < 0.02 NTU |
| Auto Range Selection | 0.01 to 19.99 NTU 20.0 to 99.9 NTU 100 to 1000 NTU |
| Resolution | 0.01 NTU (0 to 19.99 NTU) 0.1 NTU (20 to 99.9 NTU) 1 NTU (100 to 1000 NTU) |
| Precision | ±2% of reading ±1 LSD for 0-500 NTU, ±3% of reading ±1 LSD for 501-1000 NTU |
| Response Time | <6 sec. |
| Calibration Standards | 0.02 NTU, 20 NTU, 100 NTU, 800 NTU |
| Standardization | EPA approved polymer-based primary standards |
| Key Functions | Power, Cal, Scroll Up, Scroll Down, Read/Enter |
| IP Rating | IP67 |
| Battery Life | > 1200 readings |
| Sample Requirement | 10 mL (0.33 oz) |
| Sample Vials | Glass vials with screw caps, fill line and indexing mark, 51 (H) x 25 (Dia) mm ( 2 x 1 in) |
| Battery Conservation Feature | Auto shutoff after 20 minutes of inactivity |
| Self Diagnostics | Yes, with trouble shooting error codes |
| Enclosure Type | ABS plastic |
| Waterproof Rating | IP67 |
| Insulation Rating | Pollution Degree 2 |
Included:
- AQUAfast™ Turbidity Meter, AQ3010
- 92-2450-17 (Orion™ AC301S) Primary EPA-approved Turbidity Standards (0.02, 20.0, 100, and 800 NTU)
- 4 x 25 mm standard vials
- 92-2450-19 (Orion™ AC3V25) 3 x 25 mm sample vials
- 92-2450-21 (Orion™ AC3SIL) silicone oil and lint-free cloth
- 92-2450-20 (Orion™ AC3CBR) vial cleaning brush
- Light shield cover
- User guide
- Hard carrying case
Specifications
| Range | Turbidity: 0 to 1000 NTU |
|---|---|
| Range | Temperature: 0 degrees C to 50 degrees C (32 degrees F to 122 degrees F) |
| Power | 4 x AAA >3000 tests (4 x AAA Lithium >12000 tests) |
| Compliant/Standard | ISO 7027, CE, TUV 3-in-1 for CSA-US, FCC part 15 |
| Operating Environment | 0 degrees C to 50 degrees C (0 to 90% Non-Condensing Relative Humidity at 30 ºC |
| Dimensions | W x L x H: Meter: 7.9 x 17.2 x 5.0 cm (3.1 x 6.8 x 2.0 in); Meter and Case: 35 x 27 x 15 cm (13.8 x 10.6 x 5.9 in) |
| Weight | Meter: 0.23 kg (0.51 lb); Meter with case: 2.0 kg (4.4 lb) |
| Manufacturer | Thermo Scientific Orion |
| Model No | AQ3010 |
| Warranty | 90 Days (Limited) |