Description
HACH® Phosphorus (Reactive and Total) TNTplus® Vial Test, Ultra High Range (UHR) (6 to 60 mg/L PO4), 25 Tests, TNT845
Features:
- TNTplus® chemistry along with HACH spectrophotometer are engineered to simplify water analysis and provide accurate results, everytime
- For determination of both reactive (ortho), Phosphorus, Acid Hydrolyzable, and Total phosphorus (as phosphate) by HACH Ascorbic Acid Method 10209
- Safe, easy handling with innovative vial and reagent delivery system which significantly reduces spillage or contamination risk as seen with powder pillows or liquid reagents
- Reagent blank not necessary because of high quality of TNTplus® vials, tight reagent production controls, instrument calibration verification, and high instrument stability — saving time and money
- Automatic method detection with bar-coded vials which increases speed of analysis and reduces errors because instrument averages 10 readings and reject outliers caused by scratched, flawed or dirty glassware
- Documented shelf life with the 2D barcode which details batch number and expiration date and Certificate of Accuracy is available on RFID tag on the box
- Appearance:
- Phosphorus UHR TNT Reagent A: white powder
- Phosphorus UHR TNT Reagent B: colorless liquid
- Phosphorus UHR TNT Reagent C: white powder
- Phosphorus UHR TNT Reagent R-Vial: colorless liquid
- CAS Nos:
- Phosphorus UHR TNT Reagent A:
- Sodium Persulfate: 7775-27-1
- Boric Acid (HBO2) Sodium Salt Tetrahydrate: 10555-76-7
- Lithium Sulfate Monohydrate: 10102-25-7
- Phosphorus UHR TNT Reagent B:
- Sulfuric Acid: 7664-93-9
- Molybdate Hexaammonium Tetrahydrate: 12054-85-2
- Sulfamic Acid: 5329-14-6
- (+)-Tartaric Acid: 87-69-4
- Antimonate(2-),Bis[.Mu.-(2,3-Dihydroxybutanedioato(4-)-O1,O2:O3,O4)]Di-, Dipotassium,Trihydrate, Stereoisomer: 28300-74-5
- Phosphorus UHR TNT Reagent C:
- L-Ascorbic Acid: 50-81-7
- Boric Acid (HBO2) Sodium Salt Tetrahydrate: 10555-76-7
- Phosphorus UHR TNT Reagent R-Vial:
- Sulfuric Acid: 7664-93-9
- Phosphoric Acid Disodium Salt: 7558-79-4
- Phosphorus UHR TNT Reagent A:
- Shelf life: 23 months from production date
- Range: 2 to 20 mg/L PO4-P; 2 to 20 mg/L PO4-P; 6 to 60 mg/L PO4
Specifications
| D.O.T. Number | Reagents A, B, C & Vial: UN3316, 9, PG II |
|---|---|
| Other | 25 tests/PK |
| Manufacturer | HACH |
| Model No | TNT845 |
SDS PDFs
It is our policy to provide the latest Safety Data Sheet (SDS) for all chemicals we ship. Each shipment will contain copies for every chemical contained in the shipment, and for any chemical included in an instrument kit or calibration kit.
Contact us for additional copies of an SDS or for a copy of the Certificate of Analysis:
Phone: 1-800-624-8285
Email: INFO_SDS@preiser.com