Description
HACH® TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version, LPV442.99.01012
Features:
- Employs patented optical design that sees more of sample than any other turbidimeter, delivering best low level precision and sensitivity while minimizing variability from test to test
- Remove uncertainty of measurement thanks to identical 360° x 90° Detection Technology
- TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of sample meaning no need to apply silicone oil to vial and index to ensure an accurate reading
- Consistent results in lab, from operator to operator, since impact of small interferences is minimized due to collection of light at 360°.
- Only new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection delivers unprecedented confidence that change in reading is change in water quality
Included:
- TU5200 benchtop turbidimeter
- User manual
- Stablcal kit (10, 20 and 600 NTU)
- 2 sample vials
- Power supply
- Dust cover
- Vial stand
Specifications:
| Accuracy | ±2 % plus 0.01 NTU from 0 - 40 NTU; ±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C) |
| Calibration Method | For Formazin and Stablcal: 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range Custom calibration for up to 6-point calibrations Degrees 0 - 100 mg/L SDVB 0 - 1000 NTU |
| Certifications | CE compliant US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) Australian ACMA Marking |
| Display | 7" WVGA (800 x 480) color TFT-LCD with touch screen |
| Enclosure Construction | PC/ABS Blend Plastic |
| Light Source | Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50) |
| Model | TU5200 EPA |
| Regulatory | EPA |
| Repeatability | <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater >40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F) |
| Resolution | 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L |
| Response Time | Signal averaging off: 7 seconds Signal averaging on: 10 seconds (when averaging time is 5 seconds) |
| Sample Temperature | 4 - 70 °C |
| Source Lamp | 650 nm Class 2 Laser |
| Storage Conditions | -30 - 60 °C (-22 - 140 °F) |
| Stray Light | <10 mNTU |
| Units | NTU, FNU, TE/F, FTU, EBC; mg/L if calibrated with Degrees calibration curve |
Specifications
| Range | EPA Range: 0 - 700 NTU / FNU / TE/F / FTU, 0 - 100 mg/L,0 - 175 EBC |
|---|---|
| Range | ISO Range: 0 - 1000 NTU / FNU / TE/F / FTU, 0 - 100 mg/L, 0 - 250 EBC |
| Power | 100 - 240 VAC, 50 - 60 Hz |
| Compliant/Standard | CE, 1420493-000 EPA version, 1420492-000 ISO version, EPA 0.43 mW, IEC/EN 60825-1 and to 21 CFR 1040.10 |
| Operating Environment | 10 to 40 degrees C, 80 % at 30 °C (non condensing) |
| Connectivity | Link2sc |
| D.O.T. Number | Not regulated |
| Dimensions | H x W x D: 195 mm x 409 mm x 278 mm |
| Weight | 2.4 kg (5.29 lbs.) |
| Manufacturer | HACH |
| Model No | LPV442.99.01012 |
| Warranty | 12 months |