HACH® TU5200 Laboratory Laser Turbidimeter without RFID, EPA Version, LPV442.99.01012

Features:

  • Employs patented optical design that sees more of sample than any other turbidimeter, delivering best low level precision and sensitivity while minimizing variability from test to test
  • Remove uncertainty of measurement thanks to identical 360° x 90° Detection Technology
  • TU5200 Lab Turbidimeter, with the 360° x 90° Detection Technology, sees more of sample meaning no need to apply silicone oil to vial and index to ensure an accurate reading
  • Consistent results in lab, from operator to operator, since impact of small interferences is minimized due to collection of light at 360°.
  • Only new TU5 Series Lab & Process Turbidimeters with 360° x 90° Detection delivers unprecedented confidence that change in reading is change in water quality

Included:

  • TU5200 benchtop turbidimeter
  • User manual
  • Stablcal kit (10, 20 and 600 NTU)
  • 2 sample vials
  • Power supply
  • Dust cover
  • Vial stand

Specifications:

Accuracy ±2 % plus 0.01 NTU from 0 - 40 NTU;
±10 % of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C)
Calibration Method For Formazin and Stablcal:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range

Custom calibration for up to 6-point calibrations

Degrees 0 - 100 mg/L
SDVB 0 - 1000 NTU
Certifications CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
Display 7" WVGA (800 x 480) color TFT-LCD with touch screen
Enclosure Construction PC/ABS Blend Plastic
Light Source Class 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Model TU5200 EPA
Regulatory EPA
Repeatability <40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater
>40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
Resolution 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
Response Time Signal averaging off: 7 seconds
Signal averaging on: 10 seconds (when averaging time is 5 seconds)
Sample Temperature 4 - 70 °C
Source Lamp 650 nm Class 2 Laser
Storage Conditions -30 - 60 °C (-22 - 140 °F)
Stray Light <10 mNTU
Units NTU, FNU, TE/F, FTU, EBC;

mg/L if calibrated with Degrees calibration curve

Specifications

Specifications
Range EPA Range: 0 - 700 NTU / FNU / TE/F / FTU, 0 - 100 mg/L,0 - 175 EBC
Range ISO Range: 0 - 1000 NTU / FNU / TE/F / FTU, 0 - 100 mg/L, 0 - 250 EBC
Power 100 - 240 VAC, 50 - 60 Hz
Compliant/Standard CE, 1420493-000 EPA version, 1420492-000 ISO version, EPA 0.43 mW, IEC/EN 60825-1 and to 21 CFR 1040.10
Operating Environment 10 to 40 degrees C, 80 % at 30 °C (non condensing)
Connectivity Link2sc
D.O.T. Number Not regulated
Dimensions H x W x D: 195 mm x 409 mm x 278 mm
Weight 2.4 kg (5.29 lbs.)
Manufacturer HACH
Model No LPV442.99.01012
Warranty 12 months