Turbidity and Chlorine Meter, EPA Compliant Portable with Fast Tracker, Hanna Instruments, HI3414-01

Item: 92-2450-02-EA

UOM: EA (1)
Price:
Sale price$1,699.99

Description

Features:
  • High accuracy at low ranges    
  • Exclusive chlorine CAL CHECK™ calibration validation
  • Exclusive Fast Tracker™ system
  • User replaceable light source
  • Two, three or four point turbidity calibration
  • USB and RS232 PC connectivity
  • GLP features
  • Logging for up to 200 readings
  • User friendly, backlit  display with guidance codes
  • Auto-off
  • Battery % on startup
  • Continuous current time on display
 
HANNA's HI 93414 Turbidity and Chlorine Meter utilizes an EPA compliant tungsten light source and state-of-the-art optical system that allows consistently reliable and accurate measurements for free and total chlorine as well as turbidity.
Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels. To meet EPA reporting requirements these instruments have an EPA compliance reading mode. HI 93414 meets all EPA requirements with regards to the Standard Methods for Turbidity and Colorimetric Chlorine Measurements.  Turbidity is measured up to 1000 NTU and free and total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range. Depending on the measured sample and required accuracy, users can select normal measurement, continuous measurement or signal averaging.
 
HI 93414 features the ability to use Hanna's (optional) Tag Identification System (TIS) which allows users to record the time and location of a specific measurement or series of measurements. Logged data can be downloaded to a PC through either USB or RS232 connections. Reliable performance of the instrument is validated using Hanna's exclusive Cal Check® system and our ready-made, NiST traceable chlorine standards. For turbidity, a two, three or four-point calibration is available using pre-set or user defined standards. Frequent Calibration isn't necessary as the system compensates for variations in the intensity of the light source.
The instruments' Good Laboratory Practice functions allow traceability of calibration conditions including the time, date and last calibration points. At startup, the meter displays the percentage of remaining battery life. A 'low battery' warning message is also displayed on the LCD to avoid unexpected battery failure. This instrument is equipped with backlighting. The current date and time can be displayed on the LCD.
 
 
 
 
Specifications:
 
 
 
Range Turbidity 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Free and
Total Cl2
0.00 to 5.00 mg/L
Resolution Turbidity 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Free and
Total Cl2
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
Accuracy @25°C Turbidity ±2% of reading plus 0.02 NTU
Free and
Total Cl2
±0.03 mg/L ±3%  of reading (whichever is greater)
Method Turbidity Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Free and Total Cl2 adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.
Standards Turbidity <0.1, 15, 100 and 750 NTU
Free and Total Cl2 1 mg/L free chlorine, 1 mg/L total chlorine
Calibration Turbidity two, three or four-point calibration
Free and Total Cl2 one-point calibration
Light Detector Turbidity silicon photocell
Free and
Total Cl2
silicon photocell with 525 nm narrow band interference filter
Turbidity Range Selection  automatic
Stray Light  < 0.02 NTU
Measuring Mode  normal, average, continuous
Light Source  tungsten filament lamp
Lamp Life  greater than 100,000 readings
Log Memory  200 records
Serial Interface  USB or RS 232
Environment  0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply  1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight  224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

 

Supplied with:

  • HI 93414-01 Turbidity/Free & Total Chlorine Meter, 115V
  • Sample cuvettes and caps (5)
  • Calibration cuvettes for turbidity Meter (4 Standards)
  • Calibration cuvettes for Chlorine Colorimeter
  • Silicone oil
  • Cuvette wiping tissue
  • Scissors
  • Batteries
  • AC adapter
  • Instructions
  • Rugged carrying case

 

 
 